Differences in the Elemental Isotope Definition May Lead to Errors in Modern Mass-Spectrometry-Based Proteomics
Abstract
The elemental isotope definition used to calculate the theoretical masses and isotope distribution of (bio)molecules is considered to be a fixed, universal standard in mass-spectrometry-based proteomics. However, this is an incorrect assumption. In view of the ongoing advances in mass spectrometry technology, and in particular the ever-increasing mass precision, the elemental isotope definition and its variations should be taken into account. We illustrate the effect of the elemental isotope uncertainty on the theoretical and experimental masses with theoretical calculations and examples.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Mass measurement alone of intact proteins and complexes is limited because their average masses might shift slightly due to natural variations in isotopic abundance, causing mass shifts greater than the accuracy of modern high-end mass spectrometers.
“Another limitation of mass measurement alone of intact proteins and complexes is that their (average) masses might shift slightly due to natural variations in isotopic abundance, an effect which is able to cause mass shifts greater than the accuracy of modern high-end mass spectrometers.”
From Higher-order structural characterisation of native proteins and complexes by top-down mass spectrometry (2020) · cites this paper as [51]
Cites
A cross-platform toolkit for mass spectrometry and proteomics
Chambers, M., MacLean, B., Burke, R., Amodei, D., Ruderman, D., Neumann, S., Gatto, L., Fischer, B., Pratt, B. S., Egertson, J. D., et al. (2012) · Nature Biotechnology · doi:10.1038/nbt.2377 · Cited by 4,038 · see citing works
Two Categories of 13 C/ 12 C Ratios for Higher Plants
Smith, B. N., & Epstein, S. (1971) · PLANT PHYSIOLOGY · doi:10.1104/pp.47.3.380 · Cited by 2,051 · see citing works
ProteoWizard: open source software for rapid proteomics tools development
Kessner, D., Chambers, M., Burke, R., Agus, D., & Mallick, P. (2008) · Bioinformatics · doi:10.1093/bioinformatics/btn323 · Cited by 2,024 · see citing works
Isotopic compositions of the elements 2013 (IUPAC Technical Report)
Meija, J., Coplen, T. B., Berglund, M., Brand, W. A., Bièvre, P. D., Gröning, M., Holden, N. E., Irrgeher, J., Loss, R. D., Walczyk, T., et al. (2016) · Pure and Applied Chemistry · doi:10.1515/pac-2015-0503 · Cited by 1,689 · see citing works
Isotopic compositions of the elements 1997 (Technical Report)
Rosman, K., & Taylor, P. (1998) · Pure and Applied Chemistry · doi:10.1351/pac199870010217 · Cited by 932 · see citing works
McKinney, C. R., McCrea, J. M., Epstein, S., Allen, H. A., & Urey, H. C. (1950) · Review of Scientific Instruments · doi:10.1063/1.1745698 · Cited by 746 · see citing works
Mass spectrometry for proteomics
Han, X., Aslanian, A., & Yates, J. R. (2008) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2008.07.024 · Cited by 743 · see citing works
Stable isotopes as one of nature's ecological recorders
West, J. B., Bowen, G. J., Cerling, T. E., & Ehleringer, J. R. (2006) · Trends in Ecology & Evolution · doi:10.1016/j.tree.2006.04.002 · Cited by 526 · see citing works
Senko, M. W., Beu, S. C., & McLaffertycor, F. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00017-8 · Cited by 451 · see citing works
Scheltema, R. A., Hauschild, J.-P., Lange, O., Hornburg, D., Denisov, E. V., Damoc, E., Kuehn, A., Makarov, A., & Mann, M. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m114.043489 · Cited by 321 · see citing works
Atomic weights of the elements 2009 (IUPAC Technical Report)
Wieser, M. E., & Coplen, T. B. (2010) · Pure and Applied Chemistry · doi:10.1351/pac-rep-10-09-14 · Cited by 294 · see citing works
Fourier Transform Mass Spectrometry
Ščigelová, M., Hornshaw, M. P., Giannakopulos, A. E., & Makarov, A. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.009431 · Cited by 229 · see citing works
(1984) · Elsevier eBooks · doi:10.1016/c2013-0-03745-0 · Cited by 180 · see citing works
Kalli, A., Smith, G. T., Sweredoski, M. J., & Hess, S. Y. (2013) · Journal of Proteome Research · doi:10.1021/pr3011588 · Cited by 167 · see citing works
On the Proper Use of Mass Accuracy in Proteomics
Zubarev, R., & Mann, M. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m600380-mcp200 · Cited by 165 · see citing works
Accuracy Requirements for Peptide Characterization by Monoisotopic Molecular Mass Measurements
Zubarev, R. A., Håkansson, P., & Sundqvist, B. (1996) · Analytical Chemistry · doi:10.1021/ac9604651 · Cited by 129 · see citing works
Efficient calculation of accurate masses of isotopic peaks
Rockwood, A. L., & Haimi, P. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.12.001 · Cited by 108 · see citing works
Cody, R. B., Tamura, J., & Musselman, B. D. (1992) · Analytical Chemistry · doi:10.1021/ac00038a012 · Cited by 95 · see citing works
Kalli, A., & Hess, S. Y. (2011) · PROTEOMICS · doi:10.1002/pmic.201100464 · Cited by 55 · see citing works
Approaches and Limits for Accurate Mass Characterization of Large Biomolecules
Zubarev, R. A., Demirev, P. A., Håkansson, P., & Sundqvist, B. (1995) · Analytical Chemistry · doi:10.1021/ac00116a028 · Cited by 55 · see citing works
An Efficient Method to Calculate the Aggregated Isotopic Distribution and Exact Center-Masses
Claesen, J., Dittwald, P., Burzykowski, T., & Valkenborg, D. (2012) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-011-0326-2 · Cited by 52 · see citing works
Self-citationChemical mass of carbon in proteins
Beavis, R. C. (1993) · Analytical Chemistry · doi:10.1021/ac00052a030 · Cited by 46 · see citing works
Popov, I. A., Nagornov, K. O., Vladimirov, G., Kostyukevich, Y., & Николаев, Е. Н. (2014) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-014-0846-7 · Cited by 40 · see citing works
Wada, Y., Tamura, J., Musselman, B. D., et al. (1992) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290060104 · Cited by 36 · see citing works
Claesen, J., Dittwald, P., Burzykowski, T., et al. (2012) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-012-0405-z · Cited by 33 · see citing works
Self-citationInvestigating macromolecular complexes using top‐down mass spectrometry
Erba, E. B. (2014) · PROTEOMICS · doi:10.1002/pmic.201300333 · Cited by 29 · see citing works
Analysis of the stochastic variation in LTQ single scan mass spectra
Li, Q., Xia, Q., Wang, T., et al. (2006) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2471 · Cited by 14 · see citing works
The 2nd Century of IUPAC–Challenges for Reforming and Planning
Jin, B. J.-I. (2011) · Chemistry International · doi:10.1515/ci.2011.33.6.2 · Cited by 2 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Zhou, M., Lantz, C., Brown, K. A., Ge, Y., Paša-Tolić, L., Loo, J. A., & Lermyte, F. (2020) · Chemical Science · doi:10.1039/d0sc04392c · Cited by 146 · see citing works
Self-citation
- Authors
- Claesen, J., Lermyte, F., Sobott, F., Burzykowski, T., & Valkenborg, D.
- Affiliations
- Hasselt University (BE)
- University of Antwerp (BE)
- Flemish Institute for Technological Research (BE)
- Corresponding author
- Claesen, Jürgen
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-10-22
- Volume
- 87
- Issue
- 21
- Pages
- 10747-10754
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2416554609
- Cited by
- 9
- References
- 28
- Citations by year
- 2026: 1 · 2024: 3 · 2023: 2 · 2022: 1 · 2020: 1 · 2019: 1
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Document Server@UHasselt (UHasselt) (submittedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- isotope distribution, mass spectrometry-based proteomics
- MeSH terms
- Animals, Apoproteins, Elements, Horses, Isotope Labeling, Isotopes, Molecular Weight, Myoglobin, Mass Spectrometry, Proteomics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›