Capillary zone electrophoresis for bottom‐up analysis of complex proteomes
Open accessAbstract
Capillary zone electrophoresis (CZE) is emerging as a useful tool in proteomic analysis. Interest arises from dramatic improvements in performance that result from improvements in the background electrolyte used for the separation, the incorporation of advanced sample injection methods, the development of robust and sensitive electrospray interfaces, and the coupling with Orbitrap mass spectrometers with high resolution and sensitivity. The combination of these technologies produces performance that is rapidly approaching the performance of UPLC‐based methods for microgram samples and exceeds the performance of UPLC‐based methods for mid‐ to low nanogram samples. These systems now produce over 10 000 peptide IDs in a single 100‐min analysis of the HeLa proteome.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In dynamic pH junction, a focused plug forms and target analytes become positively charged and migrate toward the ESI source.
“A focused plug is formed and target analytes become positively charged, migrating towards the ESI source25,118.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [25]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 41 · Cited by 41
- Authors
- Sun, L., Zhu, G., Yan, X., Zhang, Z., Wojcik, R., Champion, M. M., & Dovichi, N. J.
- Affiliations
- University of Notre Dame (US)
- Department of Chemistry and Biochemistry University of Notre Dame Notre Dame IN USA
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2015-12-20
- Volume
- 16
- Issue
- 2
- Pages
- 188-196
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- PMC
- PMC4771184
- OpenAlex
- W2098988563
- Cited by
- 41
- References
- 41
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 1 · 2023: 1 · 2022: 2 · 2021: 3 · 2020: 5 · 2019: 3 · 2018: 7 · 2017: 7 · 2016: 7 · 2013: 1
- FWCI
- 0.67
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- PROTEOMICS (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health (R01GM096767)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Keywords
- capillary zone electrophoresis, shotgun proteomics, supporting electrolyte, Orbitrap mass spectrometry, peptide identification
- MeSH terms
- Humans, Electrophoresis, Capillary, Proteome, Spectrometry, Mass, Electrospray Ionization, Proteomics, Quality Improvement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review