Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research
Open accessAbstract
Progress in proteomics research has led to a demand for powerful analytical tools with high separation efficiency and sensitivity for confident identification and quantification of proteins, posttranslational modifications, and protein complexes expressed in cells and tissues. This demand has significantly increased interest in capillary electrophoresis‐mass spectrometry (CE‐MS) in the past few years. This review provides highlights of recent advances in CE‐MS for proteomics research, including a short introduction to top‐down mass spectrometry and native mass spectrometry (native MS), as well as a detailed overview of CE methods. Both the potential and limitations of these methods for the analysis of proteins and peptides in synthetic and biological samples and the challenges of CE methods are discussed, along with perspectives about the future direction of CE‐MS. @ 2019 Wiley Periodicals, Inc. Mass Spec Rev 00:1–16, 2019.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
0 of 181 cited sources checked · 0 supported · 0 flagged
- Premisecitation
Solvent consumption in CE-MS is very low, making it environmentally advantageous.
“In addition, solvent consumption (aqueous or organic) in CE-MS is very low, making it environmentally advantageous9.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [9] Tycova A, Ledvina V, Kleparnik K. Recent advances in CE-MS coupling: Instrumentation, methodology, and applications. Electrophoresis. 2017; 38(1): 115– 134. 27783411 source
Not checked in the free run.
- Premisecitation
Confident identification and quantification of proteins, PTMs, and peptides in biological samples depends on rigorous peptide separation before mass spectrometry.
“Confident identification and quantification of proteins, posttranslational modifications (PTMs), and peptides in biological samples rely on rigorous separation of peptides prior to introduction into the mass spectrometer1,5,6.”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [1] Zhang Y, Fonslow BR, Shan B, Baek MC, Yates JR 3rd. Protein analysis by shotgun/bottom-up proteomics. Chemical reviews. 2013; 113(4): 2343– 2394. 23438204 PMC3751594 source
Not checked in the free run.
- cites [5] Fonslow BR, Yates JR 3rd. Capillary electrophoresis applied to proteomic analysis. Journal of separation science. 2009; 32(8): 1175– 1188. 19360788 PMC3509210 source
Not checked in the free run.
- cites [6] Aebersold R, Mann M. Mass-spectrometric exploration of proteome structure and function. Nature. 2016; 537(7620): 347– 355. 27629641 source
Not checked in the free run.
- Premisecitation
Recent advances in CE-MS platforms have attracted considerable interest from the proteomics community as an alternative to LC-MS.
“Recent advances in CE-MS platforms have attracted considerable interest from the proteomics community as an alternative to LC-MS9–11.”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [9] Tycova A, Ledvina V, Kleparnik K. Recent advances in CE-MS coupling: Instrumentation, methodology, and applications. Electrophoresis. 2017; 38(1): 115– 134. 27783411 source
Not checked in the free run.
- cites [10] Stolz A, Jooss K, Hocker O, Romer J, Schlecht J, Neususs C. Recent advances in capillary electrophoresis-mass spectrometry: instrumentation, methodology and applications. Electrophoresis. 2018. 30260009 source
Not checked in the free run.
- cites [11] Bush DR, Zang L, Belov AM, Ivanov AR, Karger BL. High Resolution CZE-MS Quantitative Characterization of Intact Biopharmaceutical Proteins: Proteoforms of Interferon-beta1. Analytical chemistry. 2016; 88(2): 1138– 1146. 26641950 source
Not checked in the free run.
- Interpretationreasoning
Peptide-based methods may limit understanding of the intricate control of diverse biological activities by PTMs.
“Consequently, peptide-based methods may limit our understanding of the intricate and nuanced control of diverse biological activities by PTMs14.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [14] Toby TK, Fornelli L, Kelleher NL. Progress in Top-Down Proteomics and the Analysis of Proteoforms. Annual review of analytical chemistry (Palo Alto, Calif). 2016; 9(1): 499– 519. PMC5373801 27306313 source
Not checked in the free run.
- Premisecitation
Recent improvements in mass spectrometry instrumentation and bioinformatics have enabled TDMS to characterize and quantify hundreds to thousands of proteoforms in a single analysis.
“Recent improvements in mass spectrometry instrumentation and bioinformatics have enabled TDMS to be used to characterize and quantify hundreds to thousands of proteoforms in a single analysis16.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [16] Chen B, Brown KA, Lin Z, Ge Y. Top-Down Proteomics: Ready for Prime Time? Analytical chemistry. 2018; 90(1): 110– 127. 29161012 PMC6138622 source
Not checked in the free run.
- Premisecitation
PTMs have significant effects on the fates and functions of cellular proteins.
“It is commonly accepted that PTMs have significant effects on the fates and functions of cellular proteins17.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [17] Aebersold R, Agar JN, Amster IJ, How many human proteoforms are there? Nature chemical biology. 2018; 14(3): 206– 214. 29443976 PMC5837046 source
Not checked in the free run.
- Premisecitation
TDMS is well suited for identifying and characterizing branched systems consisting of two proteins.
“In addition, as demonstrated by Gomes and co-workers33,34, TDMS is well-suited for identification and characterization of branched systems consisting of two proteins.”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [33] Gomes F, Lemma B, Abeykoon D, Top-down Analysis of Novel Synthetic Branched Proteins. Journal of mass spectrometry: JMS. 2018. PMC7236025 30347468 source
Not checked in the free run.
- cites [34] Chen D, Gomes F, Abeykoon D, Top-Down Analysis of Branched Proteins Using Mass Spectrometry. Analytical chemistry. 2018; 90(6): 4032– 4038. 29513006 PMC6146919 source
Not checked in the free run.
- Premisecitation
CE-MS has been used to determine the purity and stability of proteins in drug discovery.
“CE–MS has been used to determine the purity and the stability of proteins in drug discovery23.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [23] Jooss K, Huhner J, Kiessig S, Moritz B, Neususs C. Two-dimensional capillary zone electrophoresis-mass spectrometry for the characterization of intact monoclonal antibody charge variants, including deamidation products. Analytical and bioanalytical chemistry. 2017; 409(26): 6057– 6067. 28801824 source
Not checked in the free run.
- Premisecitation
PTM patterns can often be lost after the protein digestion used in bottom-up approaches.
“but can often be lost after the protein digestion14,18 used in bottom-up approaches”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [14] Toby TK, Fornelli L, Kelleher NL. Progress in Top-Down Proteomics and the Analysis of Proteoforms. Annual review of analytical chemistry (Palo Alto, Calif). 2016; 9(1): 499– 519. PMC5373801 27306313 source
Not checked in the free run.
- cites [18] Biacchi M, Said N, Beck A, Leize-Wagner E, Francois YN. Top-down and middle-down approach by fraction collection enrichment using off-line capillary electrophoresis - mass spectrometry coupling: Application to monoclonal antibody Fc/2 charge variants. Journal of chromatography A. 2017; 1498: 120– 127. 28259456 source
Not checked in the free run.
- Premisecitation
Guo and co-workers provided a detailed experimental examination of a sheathless transient capillary isotachophoresis/CZE-MS interface.
“A detailed experimental examination of a sheathless transient capillary isotachophoresis (cITP)/CZE−MS interface was provided by Guo and co-workers62.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [62] Guo X, Fillmore TL, Gao Y, Tang K. Capillary Electrophoresis-Nanoelectrospray Ionization-Selected Reaction Monitoring Mass Spectrometry via a True Sheathless Metal-Coated Emitter Interface for Robust and High-Sensitivity Sample Quantification. Analytical chemistry. 2016; 88(8): 4418– 4425. 27028594 PMC4854437 source
Not checked in the free run.
- Premisecitation
Because CE separations can be performed in aqueous buffers, protein complexes can be separated in native structures, preserving non-covalent interactions before MS detection.
“Since CE separations can be performed in aqueous buffers, protein complexes can be separated in their native structures, preserving non-covalent interactions within a protein and between subunits of protein assemblies, prior to MS detection19–21.”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [19] Li H, Nguyen HH, Ogorzalek Loo RR, Campuzano IDG, Loo JA. An integrated native mass spectrometry and top-down proteomics method that connects sequence to structure and function of macromolecular complexes. Nature chemistry. 2018; 10(2): 139– 148. PMC5784781 29359744 source
Not checked in the free run.
- cites [20] Leney AC, Heck AJ. Native Mass Spectrometry: What is in the Name? Journal of the American Society for Mass Spectrometry. 2017; 28(1): 5– 13. 27909974 PMC5174146 source
Not checked in the free run.
- cites [21] Shen X, Kou Q, Guo R, Native Proteomics in Discovery Mode Using Size-Exclusion Chromatography-Capillary Zone Electrophoresis-Tandem Mass Spectrometry. Analytical chemistry. 2018; 90(17): 10095– 10099. 30085653 PMC6156775 source
Not checked in the free run.
- Premisecitation
The main challenge of the sheathless configuration is maintaining CE flow while generating a closed electrical circuit between the CE separation and the ESI source.
“In this configuration, the main challenge is maintaining CE flow while generating a closed electrical circuit between the CE separation and the ESI source5.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [5] Fonslow BR, Yates JR 3rd. Capillary electrophoresis applied to proteomic analysis. Journal of separation science. 2009; 32(8): 1175– 1188. 19360788 PMC3509210 source
Not checked in the free run.
- Premisecitation
A detection limit of 0.045 pmol/μL was achieved for the model peptide leucine enkephalin with gentle ionization.
“In this study, a detection limit of 0.045 pmol/μL was achieved for a model peptide (leucine enkephalin) with gentle ionization, which suggests its suitability to probe proteins in their tertiary and quaternary states.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [61] Nguyen TTTN Petersen NJ, Rand KD. A simple sheathless CE-MS interface with a sub-micrometer electrical contact fracture for sensitive analysis of peptide and protein samples. Analytica chimica acta. 2016; 936: 157– 167. 27566351 source
Not checked in the free run.
- Premisecitation
Nguyen and co-workers achieved high-sensitivity analysis of tryptic peptides and proteins at low nanoliter flow rates using a sheathless interface based on a sub-micrometer fracture in the capillary.
“Nguyen and co-workers achieved high sensitivity analysis of tryptic peptides and proteins at low nanoliter flow-rates using a sheathless interface that is based on a sub-micrometer fracture located directly in the capillary61.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [61] Nguyen TTTN Petersen NJ, Rand KD. A simple sheathless CE-MS interface with a sub-micrometer electrical contact fracture for sensitive analysis of peptide and protein samples. Analytica chimica acta. 2016; 936: 157– 167. 27566351 source
Not checked in the free run.
- Premisecitation
Antibodies and their glycosylated forms are often analyzed using CE-MS via top-down mass spectrometry.
“Antibodies and their related glycosylated forms are often analyzed using CE-MS via TDMS22”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [22] Han M, Rock BM, Pearson JT, Rock DA. Intact mass analysis of monoclonal antibodies by capillary electrophoresis-Mass spectrometry. Journal of chromatography B, Analytical technologies in the biomedical and life sciences. 2016; 1011: 24– 32. 26751590 source
Not checked in the free run.
- Premisecitation
This interface enabled protein characterization without dilution before nano-ESI flow rates of 10-20 nL/min.
“This interface enabled characterization of proteins without dilution prior to nano-ESI flow rates (10–20 nL/min).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [35] Belov AM, Viner R, Santos MR, Analysis of Proteins, Protein Complexes, and Organellar Proteomes Using Sheathless Capillary Zone Electrophoresis - Native Mass Spectrometry. Journal of the American Society for Mass Spectrometry. 2017; 28(12): 2614– 2634. 28875426 PMC5709234 source
Not checked in the free run.
- Premisecitation
Shen and co-workers successfully used an aqueous 25 mM ammonium acetate sheath-liquid for analysis of protein complexes from Escherichia coli.
“Shen and co-workers successfully applied an aqueous solution of 25mM ammonium acetate as a sheath-liquid for the analysis of protein complexes from Escherichia coli21.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [21] Shen X, Kou Q, Guo R, Native Proteomics in Discovery Mode Using Size-Exclusion Chromatography-Capillary Zone Electrophoresis-Tandem Mass Spectrometry. Analytical chemistry. 2018; 90(17): 10095– 10099. 30085653 PMC6156775 source
Not checked in the free run.
- Premisecitation
Belov and co-workers successfully applied an etched porous-tip sheathless interface to analyze complex-forming protein standards, a monoclonal antibody, and an Escherichia coli ribosomal proteome under native conditions.
“In a recent paper, Belov and co-workers reported a successful application of an etched porous-tip sheathless interface for analysis of complex-forming protein standards, a monoclonal antibody, and a ribosomal proteome of the Escherichia coli in native conditions35.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [35] Belov AM, Viner R, Santos MR, Analysis of Proteins, Protein Complexes, and Organellar Proteomes Using Sheathless Capillary Zone Electrophoresis - Native Mass Spectrometry. Journal of the American Society for Mass Spectrometry. 2017; 28(12): 2614– 2634. 28875426 PMC5709234 source
Not checked in the free run.
- Premisecitation
TDMS is now used in a wide range of applications, including production of therapeutic proteins such as antibody drug conjugates.
“TDMS is now being used in a wide range of applications, including the production of therapeutic proteins, such as antibody drug conjugates34.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [34] Chen D, Gomes F, Abeykoon D, Top-Down Analysis of Branched Proteins Using Mass Spectrometry. Analytical chemistry. 2018; 90(6): 4032– 4038. 29513006 PMC6146919 source
Not checked in the free run.
- Interpretationcitation
The achieved detection limit suggests that this sheathless interface is suitable for probing proteins in their tertiary and quaternary states.
“which suggests its suitability to probe proteins in their tertiary and quaternary states”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [61] Nguyen TTTN Petersen NJ, Rand KD. A simple sheathless CE-MS interface with a sub-micrometer electrical contact fracture for sensitive analysis of peptide and protein samples. Analytica chimica acta. 2016; 936: 157– 167. 27566351 source
Not checked in the free run.
- Premisecitation
Suction effects caused by the sheath-liquid and nebulizing gas can be detrimental to separation efficiency.
“Also, suction effects that are caused by both the sheath-liquid and nebulizing gas can be detrimental for separation efficiency53.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [53] Mokaddem M, Gareil P, Belgaied JE, Varenne A. New insight into suction and dilution effects in CE coupled to MS via an ESI interface. II--dilution effect. Electrophoresis. 2009; 30(10): 1692– 1697. 19360773 source
Not checked in the free run.
- Premisecitation
The ultra-low flow rates of this interface enabled higher sensitivity than sheath-liquid designs.
“The ultra-low flow rates enabled higher sensitivity from this interface than from sheath-liquid designs.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [35] Belov AM, Viner R, Santos MR, Analysis of Proteins, Protein Complexes, and Organellar Proteomes Using Sheathless Capillary Zone Electrophoresis - Native Mass Spectrometry. Journal of the American Society for Mass Spectrometry. 2017; 28(12): 2614– 2634. 28875426 PMC5709234 source
Not checked in the free run.
- Premisecitation
The porous tip sheathless interface introduced by the Moini group is the most popular sheathless prototype in proteomics research.
“The porous tip sheathless interface was introduced by the Moini group and is the most popular sheathless prototype in proteomics research55.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [55] Hocker O, Montealegre C, Neususs C. Characterization of a nanoflow sheath liquid interface and comparison to a sheath liquid and a sheathless porous-tip interface for CE-ESI-MS in positive and negative ionization. Analytical and bioanalytical chemistry. 2018; 410(21): 5265– 5275. 29943266 source
Not checked in the free run.
- Premisecitation
Characterization of PTMs is of key importance for understanding cell signaling processes related to clinical disorders.
“Thus, characterization of PTMs is of key importance for understanding cell signaling processes related to clinical disorders16.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [16] Chen B, Brown KA, Lin Z, Ge Y. Top-Down Proteomics: Ready for Prime Time? Analytical chemistry. 2018; 90(1): 110– 127. 29161012 PMC6138622 source
Not checked in the free run.
- Premisecitation
The success of native MS depends on ESI of proteins in a volatile aqueous buffer that preserves native quaternary and tertiary states in the gas phase.
“The success of native MS approaches relies on ESI of proteins in a volatile aqueous buffer that preserves native quaternary and tertiary states in the gas phase19,20.”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [19] Li H, Nguyen HH, Ogorzalek Loo RR, Campuzano IDG, Loo JA. An integrated native mass spectrometry and top-down proteomics method that connects sequence to structure and function of macromolecular complexes. Nature chemistry. 2018; 10(2): 139– 148. PMC5784781 29359744 source
Not checked in the free run.
- cites [20] Leney AC, Heck AJ. Native Mass Spectrometry: What is in the Name? Journal of the American Society for Mass Spectrometry. 2017; 28(1): 5– 13. 27909974 PMC5174146 source
Not checked in the free run.
- Premisecitation
The proteomics field has been largely dominated by bottom-up techniques in which proteins are digested before MS analysis.
“The proteomics field has been largely dominated by bottom up-based techniques, where proteins are digested prior to MS analysis1.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [1] Zhang Y, Fonslow BR, Shan B, Baek MC, Yates JR 3rd. Protein analysis by shotgun/bottom-up proteomics. Chemical reviews. 2013; 113(4): 2343– 2394. 23438204 PMC3751594 source
Not checked in the free run.
- Premisecitation
A potential limitation of the sheath-liquid interface is that high sheath-liquid flow dilutes the analyte and can cause sensitivity loss.
“A potential limitation of the sheath-liquid interface is that the high flow rate of the sheath-liquid dilutes the analyte, thereby causing a potential loss in sensitivity5,13.”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [5] Fonslow BR, Yates JR 3rd. Capillary electrophoresis applied to proteomic analysis. Journal of separation science. 2009; 32(8): 1175– 1188. 19360788 PMC3509210 source
Not checked in the free run.
- cites [13] Heemskerk AA, Deelder AM, Mayboroda OA. CE-ESI-MS for bottom-up proteomics: Advances in separation, interfacing and applications. Mass spectrometry reviews. 2016; 35(2): 259– 271. 24852088 source
Not checked in the free run.
- Premisecitation
The sheathless interface can significantly enhance signal-to-noise because analyte dilution and background noise are decreased when the BGE is the only liquid.
“In contrast, the sheathless interface can significantly enhance signal/noise due to decreased analyte dilution and background noise, as the BGE is the only liquid in the system5,54.”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [5] Fonslow BR, Yates JR 3rd. Capillary electrophoresis applied to proteomic analysis. Journal of separation science. 2009; 32(8): 1175– 1188. 19360788 PMC3509210 source
Not checked in the free run.
- cites [54] Yin Y, Li G, Guan Y, Huang G. Sheathless interface to match flow rate of capillary electrophoresis with electrospray mass spectrometry using regular-sized capillary. Rapid communications in mass spectrometry: RCM. 2016; 30 Suppl 1: 68– 72. 27539418 source
Not checked in the free run.
- Premisecitation
Most TDMS studies are performed under denaturing conditions, which disrupts biologically relevant non-covalent interactions such as protein-protein and protein-ligand complexes.
“Most TDMS studies are carried out under denaturing conditions, leading to the disruption of the biologically relevant non-covalent interactions, such as protein-protein and protein-ligand complexes35.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [35] Belov AM, Viner R, Santos MR, Analysis of Proteins, Protein Complexes, and Organellar Proteomes Using Sheathless Capillary Zone Electrophoresis - Native Mass Spectrometry. Journal of the American Society for Mass Spectrometry. 2017; 28(12): 2614– 2634. 28875426 PMC5709234 source
Not checked in the free run.
- Premisecitation
The Dovichi group reported a sequence-specific model to predict peptide electrophoretic mobility via CZE separations.
“The Dovichi group reported a sequence-specific model to predict peptide electrophoretic mobility via CZE separations75.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [75] Krokhin OV, Anderson G, Spicer V, Sun L, Dovichi NJ. Predicting Electrophoretic Mobility of Tryptic Peptides for High-Throughput CZE-MS Analysis. Analytical chemistry. 2017; 89(3): 2000– 2008. 28208305 PMC5651133 source
Not checked in the free run.
- Rests on an assumption: Residue shape and size have little effect on the electrophoretic mobility of a peptide.
- Premisecitation
Using a bottom-up approach, Zhang and co-workers identified 27,000 peptides and 4,400 proteins with CZE.
“Using a bottom-up approach, Zhang and co-workers identified 27,000 peptides and 4,400 proteins with CZE46.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [46] Zhang Z, Hebert AS, Westphall MS, Qu Y, Coon JJ, Dovichi NJ. Production of Over 27 000 Peptide and Nearly 4400 Protein Identifications by Single-Shot Capillary-Zone Electrophoresis-Mass Spectrometry via Combination of a Very-Low-Electroosmosis Coated Capillary, a Third-Generation Electrokinetically-Pumped Sheath-Flow Nanospray Interface, an Orbitrap Fusion Lumos Tribrid Mass Spectrometer, and an Advanced-Peak-Determination Algorithm. Analytical chemistry. 2018; 90(20): 12090– 12093. 30179504 PMC6508074 source
Not checked in the free run.
- Premisecitation
CZE is the most commonly used CE technique in proteomics research.
“While many CE-based techniques have been reported for the analysis of proteins and peptides, CZE is the most commonly used in proteomics research10,64–66.”
Quote in the paperNot a substantial claim0 of 4 sources checked- cites [10] Stolz A, Jooss K, Hocker O, Romer J, Schlecht J, Neususs C. Recent advances in capillary electrophoresis-mass spectrometry: instrumentation, methodology and applications. Electrophoresis. 2018. 30260009 source
Not checked in the free run.
- cites [64] Lamalle C, Servais AC, Demelenne A, Crommen J, Fillet M. Analysis of protamine peptides in insulin pharmaceutical formulations by capillary electrophoresis. Journal of separation science. 2016; 39(6): 1189– 1194. 26829340 source
Not checked in the free run.
- cites [65] Zhu Z, Lu JJ, Liu S. Protein separation by capillary gel electrophoresis: a review. Analytica chimica acta. 2012; 709: 21– 31. 22122927 PMC3227876 source
Not checked in the free run.
- cites [66] Zhang Z, Albanetti T, Linkous T, Comprehensive analysis of host cell impurities in monoclonal antibodies with improved sensitivity by capillary zone electrophoresis mass spectrometry. Electrophoresis. 2017; 38(3–4): 401– 407. 27862059 source
Not checked in the free run.
- Rests on an assumption: The most common CE-MS technique used in proteomics is capillary zone electrophoresis coupled with electrospray ionization.
- Premisecitation
Acidic residues Asp and Glu next to the N-terminus were observed to most influence the deviation of experimental mobility values from classical model predictions.
“Acidic residues (Asp and Glu) next to the N-terminus were observed to most influence the deviation of experimental mobility values from values predicted via classical models.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [75] Krokhin OV, Anderson G, Spicer V, Sun L, Dovichi NJ. Predicting Electrophoretic Mobility of Tryptic Peptides for High-Throughput CZE-MS Analysis. Analytical chemistry. 2017; 89(3): 2000– 2008. 28208305 PMC5651133 source
Not checked in the free run.
- Premisecitation
A CZE separation for top-down proteome analysis of Escherichia coli resulted in a high peak capacity of about 280.
“Figure 4 shows a CZE separation for top-down proteome analysis of Escherichia coli that resulted in high peak capacity (~ 280, calculated using the average peak width at 50% peak height for the Escherichia coli proteome sample)69.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [69] Lubeckyj RA, McCool EN, Shen X, Kou Q, Liu X, Sun L. Single-Shot Top-Down Proteomics with Capillary Zone Electrophoresis-Electrospray Ionization-Tandem Mass Spectrometry for Identification of Nearly 600 Escherichia coli Proteoforms. Analytical chemistry. 2017; 89(22): 12059– 12067. 29064224 PMC5726253 source
Not checked in the free run.
- Premisecitation
Chen and co-workers reported a model to predict the electrophoretic mobility of phosphopeptides via CZE separation.
“More recently, Chen and co-workers reported a model to predict the electrophoretic mobility of phosphopeptides via CZE separation86.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [86] Chen D, Ludwig KR, Krokhin OV, Capillary Zone Electrophoresis-Tandem Mass Spectrometry for Large-Scale Phosphoproteomics with the Production of over 11,000 Phosphopeptides from the Colon Carcinoma HCT116 Cell Line. Analytical chemistry. 2019; 91(3): 2201– 2208. 30624053 PMC6506858 source
Not checked in the free run.
- Premisecitation
The precision and robustness of CZE separations were confirmed for monoclonal antibody Fc/2 charge variants using top-down and middle-down strategies.
“In another study, the precision and robustness of CZE separations were confirmed for the analysis of monoclonal antibody Fc/2 charge variants using top-down and middle-down strategies18.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [18] Biacchi M, Said N, Beck A, Leize-Wagner E, Francois YN. Top-down and middle-down approach by fraction collection enrichment using off-line capillary electrophoresis - mass spectrometry coupling: Application to monoclonal antibody Fc/2 charge variants. Journal of chromatography A. 2017; 1498: 120– 127. 28259456 source
Not checked in the free run.
- Premisecitation
Yang et al. reported a reversed-phase LC-CZE bottom-up approach for the MCF7 proteome that identified 7,500 proteins and 60,000 peptides.
“Analysis using nano reversed-phase LC combined CZE-MS resulted in the identification of 7,500 proteins and 60,000 peptides.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [47] Yang Z, Shen X, Chen D, Sun L. Microscale Reversed-Phase Liquid Chromatography/Capillary Zone Electrophoresis-Tandem Mass Spectrometry for Deep and Highly Sensitive Bottom-Up Proteomics: Identification of 7500 Proteins with Five Micrograms of an MCF7 Proteome Digest. Analytical chemistry. 2018; 90(17): 10479– 10486. 30102516 PMC6156779 source
Not checked in the free run.
- Premisecitation
Faserl and co-workers demonstrated the value of CZE for separating 70 synthetic peptides carrying PTMs including phosphorylation, acetylation, methylation, and nitration.
“Faserl and co-workers demonstrated the value of CZE for the separation of 70 synthetic peptides that were post-translationally modified including phosphorylation, acetylation, methylation, and nitration84.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [84] Faserl K, Sarg B, Gruber P, Lindner HH. Investigating capillary electrophoresis-mass spectrometry for the analysis of common post-translational modifications. Electrophoresis. 2018; 39(9–10): 1208– 1215. 29389038 PMC6001557 source
Not checked in the free run.
- Premisecitation
CZE is particularly attractive for protein analysis because proteins have small diffusion coefficients.
“This is particularly attractive for protein analysis because they have small diffusion coefficients28,29.”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [28] Haselberg R, de Jong GJ, Somsen GW. CE-MS for the analysis of intact proteins 2010–2012. Electrophoresis. 2013; 34(1): 99– 112. 23161520 source
Not checked in the free run.
- cites [29] Haselberg R, de Jong GJ, Somsen GW. Capillary electrophoresis-mass spectrometry for the analysis of intact proteins. Journal of chromatography A. 2007; 1159(1–2): 81– 109. 17560583 source
Not checked in the free run.
- Premisecitation
This platform resulted in a peak capacity of about 4,000 for separation of intact proteins.
“This platform resulted in a peak capacity of ~4,000 for separation of intact proteins.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [51] McCool EN, Lubeckyj RA, Shen X, Deep Top-Down Proteomics Using Capillary Zone Electrophoresis-Tandem Mass Spectrometry: Identification of 5700 Proteoforms from the Escherichia coli Proteome. Analytical chemistry. 2018; 90(9): 5529– 5533. 29620868 PMC5930140 source
Not checked in the free run.
- Premisecitation
The metal coating on the ESI emitter was found to be highly sensitive and robust for approximately 100 analyses of a mixture of 9 peptide standards.
“The metal-coating on the ESI emitter was found to be highly sensitive and robust for approximately 100 analyses of a mixture of 9 peptide standards.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [62] Guo X, Fillmore TL, Gao Y, Tang K. Capillary Electrophoresis-Nanoelectrospray Ionization-Selected Reaction Monitoring Mass Spectrometry via a True Sheathless Metal-Coated Emitter Interface for Robust and High-Sensitivity Sample Quantification. Analytical chemistry. 2016; 88(8): 4418– 4425. 27028594 PMC4854437 source
Not checked in the free run.
- Premisecitation
Jooss and co-workers demonstrated the value of on-line coupling of nano reversed-phase LC and CZE for analysis of intact proteins.
“Jooss and co-workers demonstrated the value of on-line coupling of nano reversed-phase LC and CZE for analysis of intact proteins89.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [89] Jooss K, Scholz N, Meixner J, Neususs C. Heart-cut nano-LC-CZE-MS for the characterization of proteins on the intact level. Electrophoresis. 2019; 40(7): 1061– 1065. 30575976 source
Not checked in the free run.
- Premisecitation
Many studies have suggested that CZE separations are more capable of identifying hydrophilic peptides than LC.
“Many studies have suggested that CZE separations are more capable of identifying hydrophilic peptides than LC48,87.”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [48] Zhu G, Sun L, Yan X, Dovichi NJ. Single-shot proteomics using capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry with production of more than 1250 Escherichia coli peptide identifications in a 50 min separation. Analytical chemistry. 2013; 85(5): 2569– 2573. 23394296 PMC3594080 source
Not checked in the free run.
- cites [87] Wang Y, Fonslow BR, Wong CC, Nakorchevsky A, Yates JR 3rd. Improving the comprehensiveness and sensitivity of sheathless capillary electrophoresis-tandem mass spectrometry for proteomic analysis. Analytical chemistry. 2012; 84(20): 8505– 8513. 23004022 PMC3498465 source
Not checked in the free run.
- Premisecitation
McCool and co-workers demonstrated orthogonal multidimensional separation for a large-scale top-down study that identified 850 proteins and 5700 proteoforms from Escherichia coli.
“McCool and co-workers demonstrated the value of orthogonal multidimensional separation for a large-scale top-down study that identified 850 proteins and 5700 proteoforms from Escherichia coli51.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [51] McCool EN, Lubeckyj RA, Shen X, Deep Top-Down Proteomics Using Capillary Zone Electrophoresis-Tandem Mass Spectrometry: Identification of 5700 Proteoforms from the Escherichia coli Proteome. Analytical chemistry. 2018; 90(9): 5529– 5533. 29620868 PMC5930140 source
Not checked in the free run.
- Premisecitation
Jooss et al. showed the first successful application of CZE with drift tube ion mobility-mass spectrometry for separation and characterization of native and APTS-labeled N-glycans released from different protein sources.
“In another report, Jooss et al. showed, for the first time, a successful application of CZE in conjunction with drift tube ion mobility-mass spectrometry (DTIM-MS) for the separation and characterization of native and APTS-labeled N-glycans released from different protein sources90.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [90] Jooss K, Meckelmann SW, Klein J, Schmitz OJ, Neususs C. Capillary zone electrophoresis coupled to drift tube ion mobility-mass spectrometry for the analysis of native and APTS-labeled N-glycans. Analytical and bioanalytical chemistry. 2018. 30535529 source
Not checked in the free run.
- Premisecitation
Jooss and co-workers demonstrated the power of CZE-CZE-MS for characterization of intact monoclonal antibody charge variants.
“Jooss and co-workers demonstrated the power of CZE-CZE-MS for the characterization of intact monoclonal antibody charge variants23.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [23] Jooss K, Huhner J, Kiessig S, Moritz B, Neususs C. Two-dimensional capillary zone electrophoresis-mass spectrometry for the characterization of intact monoclonal antibody charge variants, including deamidation products. Analytical and bioanalytical chemistry. 2017; 409(26): 6057– 6067. 28801824 source
Not checked in the free run.
- Premisecitation
McCool and co-workers used CZE with activated ion electron transfer dissociation for TDMS of the Escherichia coli proteome and identified 328 proteins and 3028 proteoforms at 1% spectrum-level and 5% proteoform-level false discovery rates.
“More recently, McCool and co-workers reported a CZE separation in conjunction with activated ion electron transfer dissociation to interrogate the proteome of Escherichia coli via TDMS where 328 proteins and 3028 proteoforms were identified using 1% spectrum level and 5% proteoform-level false discovery rates71.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [71] McCool EN, Lodge JM, Basharat AR, Liu X, Coon JJ, Sun L. Capillary Zone Electrophoresis-Tandem Mass Spectrometry with Activated Ion Electron Transfer Dissociation for Large-scale Top-down Proteomics. Journal of the American Society for Mass Spectrometry. 2019. PMC6527361 31073891
Not checked in the free run.
- Premisecitation
Zhao and co-workers demonstrated the value of combining CZE separations with electron dissociation techniques for top-down analysis.
“Zhao and co-workers demonstrated the value of combining CZE separations with electron dissociation techniques for top-down analysis70.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [70] Zhao Y, Riley NM, Sun L, Coupling capillary zone electrophoresis with electron transfer dissociation and activated ion electron transfer dissociation for top-down proteomics. Analytical chemistry. 2015; 87(10): 5422– 5429. 25893372 PMC4439324 source
Not checked in the free run.
- Premisenone given
The electrophoretic mobility of peptides is influenced by BGE pH.
“The electrophoretic mobility of peptides is influenced by the BGE pH.”
Quote in the paperNot a substantial claim - Premisereasoning
Ammonium bicarbonate has been evaluated as an alternative to ammonium acetate for native MS because it stabilizes pH at physiological conditions.
“Ammonium bicarbonate has been evaluated as an alternative to ammonium acetate for native MS applications due to its ideal pH stabilization at physiological conditions.”
Quote in the paperNot a substantial claim - Premisenone given
A limitation of cIEF is that the catholyte is sprayed into the MS during ESI, which can affect background signal and cause ion suppression.
“A limitation of this technique that the catholyte is sprayed into the MS during the ESI process, which can affect the background signal and cause ion suppression.”
Quote in the paperNot a substantial claim - Premisenone given
Compatibility between the BGE and sheath-liquid is key to avoid moving boundaries that can adversely affect separation efficiency.
“Compatibility between the BGE and sheath-liquid is of key importance to avoid moving boundaries in the separation medium that can adversely affect the separation efficiency.”
Quote in the paperNot a substantial claim - Premisecitation
Lubeckyj and co-workers developed a strategy for large-scale top-down analysis using Escherichia coli lysate.
“A strategy for large scale top-down analysis using lysate from Escherichia coli was developed by Lubeckyj and co-workers69.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [69] Lubeckyj RA, McCool EN, Shen X, Kou Q, Liu X, Sun L. Single-Shot Top-Down Proteomics with Capillary Zone Electrophoresis-Electrospray Ionization-Tandem Mass Spectrometry for Identification of Nearly 600 Escherichia coli Proteoforms. Analytical chemistry. 2017; 89(22): 12059– 12067. 29064224 PMC5726253 source
Not checked in the free run.
- Premisenone given
A potential limitation of PEI coating is generation of very high flow-rate in the separation capillary, which becomes more problematic as BGE pH decreases.
“A potential limitation of this coating is the generation of a very high flow-rate in the separation capillary, which becomes more problematic as BGE pH is reduced.”
Quote in the paperNot a substantial claim - Premisecitation
Effective removal of SDS was demonstrated in both neutral and positively charged coated capillaries for antibody separations.
“In this approach, effective removal of SDS was demonstrated in both neutral and positively charged coated capillaries.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [111] Sanchez-Hernandez L, Montealegre C, Kiessig S, Moritz B, Neususs C. In-capillary approach to eliminate SDS interferences in antibody analysis by capillary electrophoresis coupled to mass spectrometry. Electrophoresis. 2017; 38(7): 1044– 1052. 28008632 source
Not checked in the free run.
- Premisecitation
A neutral coating was successfully used to analyze conformers and dimers of antithrombin.
“In another report, a neutral coating was successfully used for analysis of conformers and dimers of antithrombin106.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [106] Marie AL, Dominguez-Vega E, Saller F, Characterization of conformers and dimers of antithrombin by capillary electrophoresis-quadrupole-time-of-flight mass spectrometry. Analytica chimica acta. 2016; 947: 58– 65. 27846990 source
Not checked in the free run.
- Premisecitation
A BGE of 0.1% formic acid at pH 2.8 gave peak intensities equivalent to acetic acid BGEs.
“A BGE composed of 0.1% formic acid (pH 2.8) resulted in peak intensities equivalent to the acetic acid BGEs, as illustrated in the Figure 5.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [69] Lubeckyj RA, McCool EN, Shen X, Kou Q, Liu X, Sun L. Single-Shot Top-Down Proteomics with Capillary Zone Electrophoresis-Electrospray Ionization-Tandem Mass Spectrometry for Identification of Nearly 600 Escherichia coli Proteoforms. Analytical chemistry. 2017; 89(22): 12059– 12067. 29064224 PMC5726253 source
Not checked in the free run.
- Premisecitation
A PA coated capillary separated intact proteins with molecular masses from 30 to 80 kDa.
“The Kelleher group demonstrated the use of a PA coated capillary for the separation of intact proteins with molecular masses ranging from 30 to 80 kDa.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [110] Li Y, Compton PD, Tran JC, Ntai I, Kelleher NL. Optimizing capillary electrophoresis for top-down proteomics of 30–80 kDa proteins. Proteomics. 2014; 14(10): 1158– 1164. 24596178 PMC4034378 source
Not checked in the free run.
- Premisecitation
A 400 nL pH junction injection of an E. coli sample identified 527 peptides and 179 proteins.
“A 400 nL pH junction injection of an Escherichia coli sample enabled the identification of 527 peptides and 179 proteins.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [119] Zhu G, Sun L, Yan X, Dovichi NJ. Bottom-up proteomics of Escherichia coli using dynamic pH junction preconcentration and capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry. Analytical chemistry. 2014; 86(13): 6331– 6336. 24852005 PMC4082393 source
Not checked in the free run.
- Rests on an assumption: CE has very limited loading capacity, which can reduce sensitivity and peptide and protein identifications.
- Premisereasoning
Acidic pH is especially useful for peptide and protein analysis using uncoated fused silica capillaries.
“Acidic pH is especially useful in peptide and protein analysis using uncoated fused silica capillaries.”
Quote in the paperNot a substantial claim - Premisecitation
A polyacrylamide neutral coated capillary method achieved high reproducibility, with relative standard deviation for migration time in the separation window below 1%.
“These studies showed that high reproducibility with a relative standard deviation for migration time in separation window lower than 1% was achieved.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [108] Zhu G, Sun L, Dovichi NJ. Thermally-initiated free radical polymerization for reproducible production of stable linear polyacrylamide coated capillaries, and their application to proteomic analysis using capillary zone electrophoresis-mass spectrometry. Talanta. 2016; 146: 839– 843. 26695337 PMC4690009 source
Not checked in the free run.
- Premisecitation
Adding 40% acetonitrile-propan-2-ol (87.5:12.5) to 60% 150 mM ammonium formate at pH 6.0 significantly improved separation of deamidated and deacetylated TRI-1144 species and positional isomers.
“The addition of 40% of acetonitrile-propan-2-ol (87.5:12.5) to 60% 150mM ammonium formate (pH 6.0) significantly improved the separation of deamidated and deacetylated TRI-1144 species and positional isomers.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [103] Dominguez-Vega E, De Vijlder T, Romijn EP, Somsen GW. Capillary electrophoresis-tandem mass spectrometry as a highly selective tool for the compositional and site-specific assessment of multiple peptide-deamidation. Analytica chimica acta. 2017; 982: 122– 130. 28734351 source
Not checked in the free run.
- Premisecitation
Dada and co-workers evaluated a BGE composed of aqueous-aprotic dipolar solvents DMA and DMF for peptide mapping.
“Dada and co-workers evaluated a BGE composed of aqueous−aprotic dipolar solvent (N,N-dimethylacetamide (DMA) and N,N-dimethylformamide (DMF)) for peptide mapping99.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [99] Dada OO, Zhao Y, Jaya N, Salas-Solano O. High-Resolution Capillary Zone Electrophoresis with Mass Spectrometry Peptide Mapping of Therapeutic Proteins: Improved Separation with Mixed Aqueous-Aprotic Dipolar Solvents (N,N-Dimethylacetamide and N,N-Dimethylformamide) as the Background Electrolyte. Analytical chemistry. 2017; 89(21): 11227– 11235. 28972739 source
Not checked in the free run.
- Premisecitation
This BGE dramatically enhanced separation efficiency over conventional BGEs composed of acetic acid diluted in water.
“The use of this BGE dramatically enhanced the separation efficiency over conventional BGEs composed of acetic acid diluted in water.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [99] Dada OO, Zhao Y, Jaya N, Salas-Solano O. High-Resolution Capillary Zone Electrophoresis with Mass Spectrometry Peptide Mapping of Therapeutic Proteins: Improved Separation with Mixed Aqueous-Aprotic Dipolar Solvents (N,N-Dimethylacetamide and N,N-Dimethylformamide) as the Background Electrolyte. Analytical chemistry. 2017; 89(21): 11227– 11235. 28972739 source
Not checked in the free run.
- Premisecitation
Acetic acid BGEs at pH about 2.4 and 2.2 resulted in a wider separation window.
“Nevertheless, acetic acid BGEs (pH ~ 2.4 and ~2.2) resulted in a wider separation window.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [69] Lubeckyj RA, McCool EN, Shen X, Kou Q, Liu X, Sun L. Single-Shot Top-Down Proteomics with Capillary Zone Electrophoresis-Electrospray Ionization-Tandem Mass Spectrometry for Identification of Nearly 600 Escherichia coli Proteoforms. Analytical chemistry. 2017; 89(22): 12059– 12067. 29064224 PMC5726253 source
Not checked in the free run.
- Interpretationreasoning
An ammonium acetate solution at pH 6.8-7.4 becomes acidic during the ESI process.
“it suggests that an ammonium acetate solution in the pH range of 6.8 to 7.4 becomes acidic during the ESI process.”
Quote in the paperNot a substantial claim - Premisereasoning
A positively charged PEI coating generally gives high separation efficiency and high plate numbers by creating a positively charged surface and reversing EOF.
“This coating generally results in high separation efficiency with high number of plates due to its ability to create a positively charged surface on the capillary and reverse the EOF direction.”
Quote in the paperNot a substantial claim- Rests on an assumption: EOF suppression or reversal can result in higher separation efficiency.
- Premisecitation
A dynamic pH junction protocol for top-down analysis of complex samples achieved microliter-scale sample-loading volume.
“McCool and co-workers described a protocol for top-down analysis of complex samples using a dynamic pH junction where a microliter-scale sample-loading volume was achieved52.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [52] McCool EN, Lubeckyj R, Shen X, Kou Q, Liu X, Sun L. Large-scale Top-down Proteomics Using Capillary Zone Electrophoresis Tandem Mass Spectrometry. Journal of visualized experiments: JoVE. 2018(140). PMC6235596 30417888 source
Not checked in the free run.
- Rests on an assumption: CE has very limited loading capacity, which can reduce sensitivity and peptide and protein identifications.
- Premisecitation
Reproducibility of migration times between pH junction and normal injection was good.
“The authors found that reproducibility of the migration times between the pH junction and normal injection was good.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [119] Zhu G, Sun L, Yan X, Dovichi NJ. Bottom-up proteomics of Escherichia coli using dynamic pH junction preconcentration and capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry. Analytical chemistry. 2014; 86(13): 6331– 6336. 24852005 PMC4082393 source
Not checked in the free run.
- Rests on an assumption: CE has very limited loading capacity, which can reduce sensitivity and peptide and protein identifications.
- Premisecitation
A polybrene coated capillary achieved fast and reproducible separations for compositional and site-specific assessment of multiple peptide-deamidation.
“The capillary was evaluated for the analysis of compositional and site-specific assessment of multiple peptide-deamidation where fast and reproducible separations were achieved.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [103] Dominguez-Vega E, De Vijlder T, Romijn EP, Somsen GW. Capillary electrophoresis-tandem mass spectrometry as a highly selective tool for the compositional and site-specific assessment of multiple peptide-deamidation. Analytica chimica acta. 2017; 982: 122– 130. 28734351 source
Not checked in the free run.
- Premisecitation
A neutral capillary produced almost zero EOF for intact protein analysis.
“Haselberg et al. reported almost zero EOF with the use of a neutral capillary for the analysis of intact proteins105.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [105] Haselberg R, De Vijlder T, Heukers R, Heterogeneity assessment of antibody-derived therapeutics at the intact and middle-up level by low-flow sheathless capillary electrophoresis-mass spectrometry. Analytica chimica acta. 2018; 1044: 181– 190. 30442400 source
Not checked in the free run.
- Premisecitation
Acidic N-linked glycans were successfully analyzed using a neutral coated capillary.
“Acidic N-linked glycans were also successfully analyzed using a neutral coated capillary107.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [107] Partyka J, Krenkova J, Cmelik R, Foret F. Multi-charged labeling of oligosaccharides and N-linked glycans by hexahistidine-based tags for capillary electrophoresis-mass spectrometry analysis. Journal of chromatography A. 2018; 1560: 91– 96. 29778448 source
Not checked in the free run.
- Premisecitation
Dai and Zhang used cIEF with a middle-down strategy to reduce sample complexity and characterize charge heterogeneity of the same monoclonal antibody.
“In another report, Dai and Zhang used cIEF with a middle-down strategy to reduce sample complexity to achieve characterization of the charge heterogeneity for the same monoclonal antibody93.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [93] Dai J, Zhang Y. A Middle-Up Approach with Online Capillary Isoelectric Focusing-Mass Spectrometry for In-depth Characterization of Cetuximab Charge Heterogeneity. Analytical chemistry. 2018. 30451489 source
Not checked in the free run.
- Premisecitation
PEI coated capillaries demonstrated high separation efficiency for protein complexes and Pyrococcus furiosus proteins via TDMS.
“Han et al. demonstrated the high separation efficiency of PEI coated capillaries for the analysis of protein complexes and Pyrococcus furiosus proteins via TDMS59,60.”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [59] Han X, Wang Y, Aslanian A, In-line separation by capillary electrophoresis prior to analysis by top-down mass spectrometry enables sensitive characterization of protein complexes. Journal of proteome research. 2014; 13(12): 6078– 6086. 25382489 PMC4262260 source
Not checked in the free run.
- cites [60] Han X, Wang Y, Aslanian A, Bern M, Lavallee-Adam M, Yates JR 3rd. Sheathless capillary electrophoresis-tandem mass spectrometry for top-down characterization of Pyrococcus furiosus proteins on a proteome scale. Analytical chemistry. 2014; 86(22): 11006– 11012. 25346219 PMC4238646 source
Not checked in the free run.
- Interpretationcitation
The improvement in separation efficiency may be attributed to DMA's influence on peptide electrophoretic mobility and electroosmotic flow.
“The improvement in separation efficiency might be attributed to the influence of DMA on the electrophoretic mobility of the peptides and EOF.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [99] Dada OO, Zhao Y, Jaya N, Salas-Solano O. High-Resolution Capillary Zone Electrophoresis with Mass Spectrometry Peptide Mapping of Therapeutic Proteins: Improved Separation with Mixed Aqueous-Aprotic Dipolar Solvents (N,N-Dimethylacetamide and N,N-Dimethylformamide) as the Background Electrolyte. Analytical chemistry. 2017; 89(21): 11227– 11235. 28972739 source
Not checked in the free run.
- Premisenone given
Dynamic pH junction stacking has recently been used in top-down and bottom-up proteomics.
“Recently, a dynamic pH junction has been used in top-down and bottom-up proteomics.”
Quote in the paperNot a substantial claim- Rests on an assumption: CE has very limited loading capacity, which can reduce sensitivity and peptide and protein identifications.
- Premisenone given
BGE selection is critical for successful CE separation and MS sensitivity.
“BGE selection is critical to ensure successful CE separation and MS sensitivity.”
Quote in the paperNot a substantial claim - Premisecitation
Ammonium acetate does not form a buffer system that can effectively maintain macromolecular complexes in solution at physiological pH.
“Since ammonium acetate does not constitute a buffer system that can effectively maintain macromolecular complexes in solution at physiological pH conditions81,100”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [81] Konermann L Addressing a Common Misconception: Ammonium Acetate as Neutral pH “Buffer” for Native Electrospray Mass Spectrometry. Journal of the American Society for Mass Spectrometry. 2017; 28(9): 1827– 1835. 28710594 source
Not checked in the free run.
- cites [100] Kebarle P, Verkerk UH. Electrospray: from ions in solution to ions in the gas phase, what we know now. Mass spectrometry reviews. 2009; 28(6): 898– 917. 19551695 source
Not checked in the free run.
- Premisecitation
CE-MS with selected reaction monitoring provided reliable quantification of a peptide mixture with a coefficient of variation between 0.2 and 1.8% for migration time.
“The method was highly reproducible and robust and provided reliable quantification of a peptide mixture with a coefficient of variation (CV) between 0.2 and 1.8% for the migration time.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [62] Guo X, Fillmore TL, Gao Y, Tang K. Capillary Electrophoresis-Nanoelectrospray Ionization-Selected Reaction Monitoring Mass Spectrometry via a True Sheathless Metal-Coated Emitter Interface for Robust and High-Sensitivity Sample Quantification. Analytical chemistry. 2016; 88(8): 4418– 4425. 27028594 PMC4854437 source
Not checked in the free run.
- Premisecitation
CZE-MS and LC-MS identified no significant difference in the number of peptides and proteins for E. coli samples using on-line SPE preconcentration with dynamic pH separation.
“There was no significant difference in the number of peptides and proteins identified by CZE-MS and LC-MS methods.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [125] Zhang Z, Yan X, Sun L, Zhu G, Dovichi NJ. Detachable strong cation exchange monolith, integrated with capillary zone electrophoresis and coupled with pH gradient elution, produces improved sensitivity and numbers of peptide identifications during bottom-up analysis of complex proteomes. Analytical chemistry. 2015; 87(8): 4572– 4577. 25822566 PMC4406858 source
Not checked in the free run.
- Rests on an assumption: CE has very limited loading capacity, which can reduce sensitivity and peptide and protein identifications.
- Premisecitation
A SILAC CE-MS approach quantified 1371 phosphopeptides without enrichment.
“Faserl and co-workers reported a SILAC approach that resulted in a quantification of 1371 phosphopeptides by CE-MS, without using any enrichment strategy127.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [127] Faserl K, Kremser L, Muller M, Teis D, Lindner HH. Quantitative proteomics using ultralow flow capillary electrophoresis-mass spectrometry. Analytical chemistry. 2015; 87(9): 4633– 4640. 25839223 PMC4423236 source
Not checked in the free run.
- Interpretationnone given
CE-MS use for quantitative proteomics, TDMS, and native MS is exceedingly low, with only a few publications in recent years.
“The use of CE-MS for quantitative proteomics, TDMS, and native MS is exceedingly low, with only a few publications over the past few years.”
Quote in the paperNot a substantial claim - Premisecitation
Reversed-phase SPE with CE can trap large sample volumes and elute them with an elution buffer before CE separation.
“Sample preconcentration using a chromatographic principle such as SPE was used by Wang et al. where large sample volumes can be trapped on reversed-phase media and eluted using an elution buffer prior to CE separation123.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [123] Tong W, Link A, Eng JK, Yates JR 3rd. Identification of proteins in complexes by solid-phase microextraction/multistep elution/capillary electrophoresis/tandem mass spectrometry. Analytical chemistry. 1999; 71(13): 2270– 2278. 10405597 source
Not checked in the free run.
- Rests on an assumption: CE has very limited loading capacity, which can reduce sensitivity and peptide and protein identifications.
- Premisecitation
tITP requires optimization of both electrolyte concentrations and loading volume for efficient stacking of target analytes.
“tITP requires an optimization of both electrolyte concentrations and loading volume to enable efficient stacking of the target analytes13,27,65,120–122.”
Quote in the paperNot a substantial claim0 of 6 sources checked- cites [13] Heemskerk AA, Deelder AM, Mayboroda OA. CE-ESI-MS for bottom-up proteomics: Advances in separation, interfacing and applications. Mass spectrometry reviews. 2016; 35(2): 259– 271. 24852088 source
Not checked in the free run.
- cites [27] Zhang Z, Qu Y, Dovichi NJ. Capillary zone electrophoresis-mass spectrometry for bottom-up proteomics. TrAC Trends in Analytical Chemistry. 2018; 108: 23– 37. source
Not checked in the free run.
- cites [65] Zhu Z, Lu JJ, Liu S. Protein separation by capillary gel electrophoresis: a review. Analytica chimica acta. 2012; 709: 21– 31. 22122927 PMC3227876 source
Not checked in the free run.
- cites [120] Wang C, Lee CS, Smith RD, Tang K. Ultrasensitive sample quantitation via selected reaction monitoring using CITP/CZE-ESI-triple quadrupole MS. Analytical chemistry. 2012; 84(23): 10395– 10403. 23140208 PMC3547498 source
Not checked in the free run.
- cites [121] Wang C, Lee CS, Smith RD, Tang KJAc. CITP/CZE-nanoESI-SRM MS via a novel sheathless interface for high sensitivity sample quantification. 2013; 85(15): 7308. PMC3744340 23789856 source
Not checked in the free run.
- cites [122] Heemskerk AA, Wuhrer M, Busnel JM, Coupling porous sheathless interface MS with transient-ITP in neutral capillaries for improved sensitivity in glycopeptide analysis. Electrophoresis. 2013; 34(3): 383– 387. 23161657 source
Not checked in the free run.
- Rests on an assumption: CE has very limited loading capacity, which can reduce sensitivity and peptide and protein identifications.
- Premisecitation
Low sample consumption of CE allowed quantitative studies of the same sample by LC-MS.
“The low sample consumption of CE enabled them to perform quantitative studies of the same sample via LC-MS.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [128] Varadi C, Mittermayr S, Millan-Martin S, Bones J. Quantitative twoplex glycan analysis using (12)C6 and (13)C6 stable isotope 2-aminobenzoic acid labelling and capillary electrophoresis mass spectrometry. Analytical and bioanalytical chemistry. 2016; 408(30): 8691– 8700. 27662881 source
Not checked in the free run.
- Interpretationreasoning
Interface improvements have enhanced sensitivity, enabling CE application to complex and low-concentration samples.
“These improvements have also enhanced sensitivity, enabling the application of CE to complex and low concentrated samples.”
Quote in the paperSubstantial claim - Premisecitation
Label-free single-cell CE-MS quantified about 750 protein groups in a 16-cell Xenopus laevis embryo with about 5 ng of protein digest.
“More recently, the same research group reported the use of CE-MS in conjunction with label-free single-cell proteomics for quantification ~ 750 protein groups in 16-cell Xenopus laevis (frog) embryo with about 5ng of protein digest131.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [131] Lombard-Banek C, Moody SA, Manzini MC, Nemes P. Microsampling Capillary Electrophoresis Mass Spectrometry Enables Single-Cell Proteomics in Complex Tissues: Developing Cell Clones in Live Xenopus laevis and Zebrafish Embryos. Analytical chemistry. 2019; 91(7): 4797– 4805. 30827088 PMC6688183 source
Not checked in the free run.
- Premisecitation
CE-MS quantitative performance was similar to LC-MS.
“In terms of quantitative performance, CE-MS was found to be similar to LC-MS.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [128] Varadi C, Mittermayr S, Millan-Martin S, Bones J. Quantitative twoplex glycan analysis using (12)C6 and (13)C6 stable isotope 2-aminobenzoic acid labelling and capillary electrophoresis mass spectrometry. Analytical and bioanalytical chemistry. 2016; 408(30): 8691– 8700. 27662881 source
Not checked in the free run.
- Premisecitation
Label-free CZE-MS quantified thousands of proteoforms from zebrafish brain.
“In a TDMS study, Lubeckyj et al. demonstrated a label-free strategy for the quantification of thousands of proteoforms from zebrafish brain using CZE-MS135.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [135] Lubeckyj RA, Basharat AR, Shen X, Liu X, Sun L. Large-Scale Qualitative and Quantitative Top-Down Proteomics Using Capillary Zone Electrophoresis-Electrospray Ionization-Tandem Mass Spectrometry with Nanograms of Proteome Samples. Journal of the American Society for Mass Spectrometry. 2019. PMC6675661 30972727 source
Not checked in the free run.
- Premisecitation
CE-MS analysis of intact glycoforms estimated glycoform concentrations between 0.35 and 630 nM based on relative intensities.
“Quantitative information was based on the relative intensities of the detected glycoforms where glycoform concentrations were estimated to range between 0.35 to 630 nM.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [134] Haselberg R, de Jong GJ, Somsen GW. Low-flow sheathless capillary electrophoresis-mass spectrometry for sensitive glycoform profiling of intact pharmaceutical proteins. Analytical chemistry. 2013; 85(4): 2289– 2296. 23323765 source
Not checked in the free run.
- Premisecitation
The two-plex CE-MS method applied to a therapeutic protein revealed differences in N-glycan structures between two lots.
“It was further applied for analysis of a therapeutic protein where the authors observed differences in N-glycan structures from two different lots.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [128] Varadi C, Mittermayr S, Millan-Martin S, Bones J. Quantitative twoplex glycan analysis using (12)C6 and (13)C6 stable isotope 2-aminobenzoic acid labelling and capillary electrophoresis mass spectrometry. Analytical and bioanalytical chemistry. 2016; 408(30): 8691– 8700. 27662881 source
Not checked in the free run.
- Premisecitation
CE-MS quantification of about 150 non-redundant protein groups in single embryonic cells revealed significant translational cell heterogeneity along multiple axes of the embryo at a very early stage.
“In this study, the quantification of ~150 non-redundant protein groups revealed significant translational cell heterogeneity along multiple axes of the embryo at very early stage of development.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [130] Lombard-Banek C, Moody SA, Nemes P. Single-Cell Mass Spectrometry for Discovery Proteomics: Quantifying Translational Cell Heterogeneity in the 16-Cell Frog (Xenopus) Embryo. Angewandte Chemie (International ed in English). 2016; 55(7): 2454– 2458. 26756663 PMC4755155 source
Not checked in the free run.
- Premisenone given
In CE-MS via TDMS, comparing peak intensities of unmodified and modified proteins gives the abundance of a proteoform.
“In quantification using CE-MS via TDMS, the intensities of the peaks corresponding to unmodified and modified proteins can be compared to obtain the abundance of a proteoform.”
Quote in the paperSubstantial claim - Premisecitation
Extending pH junction to three intact standard proteins increased peak intensity more than 10-fold compared to conventional injection.
“The pH junction was further extended to three intact standard proteins where the peak intensity increased more than 10-fold compared to conventional injection.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [119] Zhu G, Sun L, Yan X, Dovichi NJ. Bottom-up proteomics of Escherichia coli using dynamic pH junction preconcentration and capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry. Analytical chemistry. 2014; 86(13): 6331– 6336. 24852005 PMC4082393 source
Not checked in the free run.
- Rests on an assumption: CE has very limited loading capacity, which can reduce sensitivity and peptide and protein identifications.
- Premisecitation
LC-MS failed to resolve N-glycan isomers that CE-MS resolved.
“However, the LC-MS platform failed to resolve N-glycan isomers that were resolved via CE-MS.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [128] Varadi C, Mittermayr S, Millan-Martin S, Bones J. Quantitative twoplex glycan analysis using (12)C6 and (13)C6 stable isotope 2-aminobenzoic acid labelling and capillary electrophoresis mass spectrometry. Analytical and bioanalytical chemistry. 2016; 408(30): 8691– 8700. 27662881 source
Not checked in the free run.
- Interpretationnone given
State-of-the-art single-shot CZE-ESI-MS with neutrally coated capillaries about 1 meter long has substantially enhanced peak capacity of CE-MS in proteomics.
“The state-of-the-art single shot CZE-ESI-MS, along with neutrally coated capillaries (~1 meter), have substantially enhanced the peak capacity of CE-MS methods in proteomics research.”
Quote in the paperNot a substantial claim - Premisecitation
Capillary electrochromatography has been successfully applied for separation of peptides.
“Another example is capillary electrochromatography that has been successfully applied for the separation of peptides138,139.”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [138] Ali F, Cheong WJ. Open tubular capillary column for the separation of cytochrome C tryptic digest in capillary electrochromatography. Journal of separation science. 2015; 38(20): 3645– 3654. 26289407 source
Not checked in the free run.
- cites [139] Ali F, Cheong WJJBotKCS. High efficiency robust open tubular capillary electrochromatography column for the separation of peptides. 2016; 37(8): 1374– 1377.
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Premisecitation
The quantitative CZE-MS approach revealed that proteoform abundance differs significantly in different regions of the zebrafish brain.
“This quantitative approach revealed that the abundance of proteoforms differs significantly in different regions of the zebrafish brain.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [135] Lubeckyj RA, Basharat AR, Shen X, Liu X, Sun L. Large-Scale Qualitative and Quantitative Top-Down Proteomics Using Capillary Zone Electrophoresis-Electrospray Ionization-Tandem Mass Spectrometry with Nanograms of Proteome Samples. Journal of the American Society for Mass Spectrometry. 2019. PMC6675661 30972727 source
Not checked in the free run.
- Premisecitation
Microchip CE-MS analysis of a bovine hemoglobin pepsin digest demonstrated high peak capacity and speed compared to conventional LC separation of the same sample.
“For instance, microchip CE-MS analysis of a bovine hemoglobin pepsin digest has demonstrated high peak capacity and speed when compared to a conventional LC separation of the same sample136.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [136] Black WA, Stocks BB, Mellors JS, Engen JR, Ramsey JM. Utilizing Microchip Capillary Electrophoresis Electrospray Ionization for Hydrogen Exchange Mass Spectrometry. Analytical chemistry. 2015; 87(12): 6280– 6287. 25992468 PMC4470751 source
Not checked in the free run.
- Premisecitation
Microchip CE-MS separated intact monoclonal antibody variants with fast analysis of about 4 minutes.
“The use of microchip CE-MS has also been demonstrated for the separation of intact monoclonal antibody variants where fast analysis was achieved (~ 4 min)137.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [137] Redman EA, Batz NG, Mellors JS, Ramsey JM. Integrated microfluidic capillary electrophoresis-electrospray ionization devices with online MS detection for the separation and characterization of intact monoclonal antibody variants. Analytical chemistry. 2015; 87(4): 2264– 2272. 25569459 source
Not checked in the free run.
- Interpretationreasoning
Advances in MS technologies and the need for high-speed, high-resolving separation techniques have renewed interest in CE-MS for proteomics in recent years.
“In the past few years advances in MS technologies, along with the need for separation techniques with high speed and resolving power, have renewed interest in the use of CE-MS for proteomics research.”
Quote in the paperSubstantial claim
- Classified as probably not a substantial claim. 20
- May combine two claims. 57
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationMass spectrometry-based methods remain the most widely used approach for high-throughput proteomics research.
“Mass spectrometry (MS)–based methods continue to be the most widely used methods for high-throughput proteomics research1–4”
Quote in the paperNot a substantial claim0 of 4 sources checked- cites [1] Zhang Y, Fonslow BR, Shan B, Baek MC, Yates JR 3rd. Protein analysis by shotgun/bottom-up proteomics. Chemical reviews. 2013; 113(4): 2343– 2394. 23438204 PMC3751594 source
Not checked in the free run.
- cites [2] Yates JR, Ruse CI, Nakorchevsky A. Proteomics by mass spectrometry: approaches, advances, and applications. Annual review of biomedical engineering. 2009; 11: 49– 79. 19400705 source
Not checked in the free run.
- cites [3] Nilsson T, Mann M, Aebersold R, Yates JR 3rd, Bairoch A, Bergeron JJ. Mass spectrometry in high-throughput proteomics: ready for the big time. Nature methods. 2010; 7(9): 681– 685. 20805795 source
Not checked in the free run.
- cites [4] Yates JR 3rd. The revolution and evolution of shotgun proteomics for large-scale proteome analysis. Journal of the American Chemical Society. 2013; 135(5): 1629– 1640. 23294060 PMC3751590 source
Not checked in the free run.
May combine two claims.
PremisecitationCapillary electrophoresis is a mature separation technology that couples effectively with mass spectrometry and is well suited for peptide separation.
“Capillary electrophoresis is a mature separation technology that is effectively coupled with mass spectrometry (CE-MS) and is well suited for this purpose7,8.”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [7] Mischak H, Coon JJ, Novak J, Weissinger EM, Schanstra JP, Dominiczak AF. Capillary electrophoresis-mass spectrometry as a powerful tool in biomarker discovery and clinical diagnosis: an update of recent developments. Mass spectrometry reviews. 2009; 28(5): 703– 724. 18973238 PMC2720435 source
Not checked in the free run.
- cites [8] Belczacka I, Latosinska A, Siwy J, Urinary CE-MS peptide marker pattern for detection of solid tumors. Scientific reports. 2018; 8(1): 5227– 5227. 29588543 PMC5869723 source
Not checked in the free run.
May combine two claims.
PremisecitationNative MS provides a proteomics tool that enables identification and characterization of biomolecular structures and advances understanding of biological pathways at the molecular level.
“Native MS provides a proteomics tool that enables identification and characterization of these biomolecular structures and advances the understanding of their biological pathways at the molecular level19,20,35.”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [19] Li H, Nguyen HH, Ogorzalek Loo RR, Campuzano IDG, Loo JA. An integrated native mass spectrometry and top-down proteomics method that connects sequence to structure and function of macromolecular complexes. Nature chemistry. 2018; 10(2): 139– 148. PMC5784781 29359744 source
Not checked in the free run.
- cites [20] Leney AC, Heck AJ. Native Mass Spectrometry: What is in the Name? Journal of the American Society for Mass Spectrometry. 2017; 28(1): 5– 13. 27909974 PMC5174146 source
Not checked in the free run.
- cites [35] Belov AM, Viner R, Santos MR, Analysis of Proteins, Protein Complexes, and Organellar Proteomes Using Sheathless Capillary Zone Electrophoresis - Native Mass Spectrometry. Journal of the American Society for Mass Spectrometry. 2017; 28(12): 2614– 2634. 28875426 PMC5709234 source
Not checked in the free run.
- Rests on an assumption: Most proteins are assembled into protein complexes to achieve functional activity.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationCapillary isoelectric focusing is a useful but less commonly used CE technique in proteomics.
“Capillary isoelectric focusing (cIEF)12 is another useful, but less commonly used CE technique.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [12] Kahle J, Stein M, Watzig H. Design of experiments as a valuable tool for biopharmaceutical analysis with (imaged) capillary isoelectric focusing. Electrophoresis. 2019. 31177564 source
Not checked in the free run.
May combine two claims.
PremisecitationTop-down analysis can provide unique structural insights into proteins through precise molecular weight measurements, identification of multiple PTMs, and in-depth proteoform characterization.
“Top-down analysis can provide unique insights into a protein’s structure by providing precise molecular weight measurements, the identification of multiple PTMs5,16,28 and in-depth proteoform characterization (different forms of a single protein generated from a gene)32.”
Quote in the paperSubstantial claim0 of 4 sources checked- cites [5] Fonslow BR, Yates JR 3rd. Capillary electrophoresis applied to proteomic analysis. Journal of separation science. 2009; 32(8): 1175– 1188. 19360788 PMC3509210 source
Not checked in the free run.
- cites [16] Chen B, Brown KA, Lin Z, Ge Y. Top-Down Proteomics: Ready for Prime Time? Analytical chemistry. 2018; 90(1): 110– 127. 29161012 PMC6138622 source
Not checked in the free run.
- cites [28] Haselberg R, de Jong GJ, Somsen GW. CE-MS for the analysis of intact proteins 2010–2012. Electrophoresis. 2013; 34(1): 99– 112. 23161520 source
Not checked in the free run.
- cites [32] Smith LM, Kelleher NL. Proteoform: a single term describing protein complexity. Nature methods. 2013; 10(3): 186– 187. 23443629 PMC4114032 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationTop-down mass spectrometry is an emerging approach that provides detailed structural information on intact proteins, including PTM characterization.
“TDMS is an emerging approach that provides detailed structural information on intact proteins, including characterization of PTMs16.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [16] Chen B, Brown KA, Lin Z, Ge Y. Top-Down Proteomics: Ready for Prime Time? Analytical chemistry. 2018; 90(1): 110– 127. 29161012 PMC6138622 source
Not checked in the free run.
May combine two claims.
PremisecitationNative MS can interrogate intact proteins in a near native state while preserving noncovalent protein-protein and protein-ligand complexes.
“Native MS can be used to interrogate the structure of intact proteins in their near native state, with an emphasis on preserving noncovalent protein-protein and protein-ligand complexes20.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [20] Leney AC, Heck AJ. Native Mass Spectrometry: What is in the Name? Journal of the American Society for Mass Spectrometry. 2017; 28(1): 5– 13. 27909974 PMC5174146 source
Not checked in the free run.
May combine two claims.
PremisecitationBottom-up approaches are high-throughput, but critical information about PTMs and subunit protein assemblies is generally lost after proteolysis.
“This approach is well-known for its high-throughput performance; however, critical information about PTMs and subunit protein assemblies (via non-covalent interactions) is generally lost after proteolysis14,31.”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [14] Toby TK, Fornelli L, Kelleher NL. Progress in Top-Down Proteomics and the Analysis of Proteoforms. Annual review of analytical chemistry (Palo Alto, Calif). 2016; 9(1): 499– 519. PMC5373801 27306313 source
Not checked in the free run.
- cites [31] Catherman AD, Skinner OS, Kelleher NL. Top Down proteomics: facts and perspectives. Biochemical and biophysical research communications. 2014; 445(4): 683– 693. 24556311 PMC4103433 source
Not checked in the free run.
May combine two claims.
PremisecitationNative MS provides information about ligand binding, dynamics, subunit stoichiometry, stability, topology, and assembly structural properties.
“Native MS provides information about ligand binding, dynamics, stoichiometry of individual subunits, stability, topology, and assembly structural properties35.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [35] Belov AM, Viner R, Santos MR, Analysis of Proteins, Protein Complexes, and Organellar Proteomes Using Sheathless Capillary Zone Electrophoresis - Native Mass Spectrometry. Journal of the American Society for Mass Spectrometry. 2017; 28(12): 2614– 2634. 28875426 PMC5709234 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationPTM patterns can provide insight into potentially significant biological processes.
“PTM patterns can provide insight into potentially significant biological processes14,16,17”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [14] Toby TK, Fornelli L, Kelleher NL. Progress in Top-Down Proteomics and the Analysis of Proteoforms. Annual review of analytical chemistry (Palo Alto, Calif). 2016; 9(1): 499– 519. PMC5373801 27306313 source
Not checked in the free run.
- cites [16] Chen B, Brown KA, Lin Z, Ge Y. Top-Down Proteomics: Ready for Prime Time? Analytical chemistry. 2018; 90(1): 110– 127. 29161012 PMC6138622 source
Not checked in the free run.
- cites [17] Aebersold R, Agar JN, Amster IJ, How many human proteoforms are there? Nature chemical biology. 2018; 14(3): 206– 214. 29443976 PMC5837046 source
Not checked in the free run.
May combine two claims.
PremisecitationThe sheathless interface has been widely used for ultrasensitive proteomics analysis, although it is limited by potential pore blocking.
“The sheathless interface has been widely used in proteomics research to provide ultrasensitive analysis56–58, although it is limited by potential blocking of the pores.”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [56] Kammeijer GS, Kohler I, Jansen BC, Dopant Enriched Nitrogen Gas Combined with Sheathless Capillary Electrophoresis-Electrospray Ionization-Mass Spectrometry for Improved Sensitivity and Repeatability in Glycopeptide Analysis. Analytical chemistry. 2016; 88(11): 5849– 5856. 27119460 source
Not checked in the free run.
- cites [57] Snyder CM, Zhou X, Karty JA, Fonslow BR, Novotny MV, Jacobson SC. Capillary electrophoresis-mass spectrometry for direct structural identification of serum N-glycans. Journal of chromatography A. 2017; 1523: 127– 139. 28989033 PMC5691604 source
Not checked in the free run.
- cites [58] Medina-Casanellas S, Domínguez-Vega E, Benavente F, Sanz-Nebot V, Somsen GW, de Jong GJ. Low-picomolar analysis of peptides by on-line coupling of fritless solid-phase extraction to sheathless capillary electrophoresis-mass spectrometry. Journal of Chromatography A. 2014; 1328: 1– 6. 24438833 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThe Kelleher group reported a standard operating procedure for native MS.
“Recently, the Kelleher group reported a standard operating procedure for native MS38.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [38] Schachner LF, Ives AN, McGee JP, Standard Proteoforms and Their Complexes for Native Mass Spectrometry. Journal of the American Society for Mass Spectrometry. 2019. PMC6592724 30963455 source
Not checked in the free run.
May combine two claims.
PremisecitationShen and co-workers demonstrated SEC-CZE for analysis of protein complexes and proteoforms under near native conditions, identifying 144 proteins, 672 proteoforms, and 23 protein complexes from the Escherichia coli proteome.
“More recently, Shen and co-workers demonstrated the use of SEC-CZE for analysis of protein complexes and proteoforms under near native conditions21, resulting in the identification of 144 proteins, 672 proteoforms, and 23 protein complexes from the Escherichia coli proteome.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [21] Shen X, Kou Q, Guo R, Native Proteomics in Discovery Mode Using Size-Exclusion Chromatography-Capillary Zone Electrophoresis-Tandem Mass Spectrometry. Analytical chemistry. 2018; 90(17): 10095– 10099. 30085653 PMC6156775 source
Not checked in the free run.
May combine two claims.
PremisecitationQu and co-workers reported an LC-CZE strategy for site-specific glycan heterogeneity in which CZE analysis of reversed-phase LC glycopeptide fractions reduced sample complexity and enabled glycan structural elucidation.
“Qu and co-workers reported a LC-CZE strategy for the characterization of site-specific glycan heterogeneity where the use of CZE for analysis of reversed-phase LC glycopeptide fractions reduced the complexity of the sample and enabled glycan structural elucidation88.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [88] Qu Y, Sun L, Zhang Z, Dovichi NJ. Site-Specific Glycan Heterogeneity Characterization by Hydrophilic Interaction Liquid Chromatography Solid-Phase Extraction, Reversed-Phase Liquid Chromatography Fractionation, and Capillary Zone Electrophoresis-Electrospray Ionization-Tandem Mass Spectrometry. Analytical chemistry. 2018; 90(2): 1223– 1233. 29231704 PMC5771954 source
Not checked in the free run.
May combine two claims.
InterpretationcitationHigh peak capacity and resolving power improved data acquisition and enhanced representation of proteins in the sample.
“High peak capacity and resolving power improved the data acquisition, which resulted in an enhanced representation of the proteins in the sample.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [51] McCool EN, Lubeckyj RA, Shen X, Deep Top-Down Proteomics Using Capillary Zone Electrophoresis-Tandem Mass Spectrometry: Identification of 5700 Proteoforms from the Escherichia coli Proteome. Analytical chemistry. 2018; 90(9): 5529– 5533. 29620868 PMC5930140 source
Not checked in the free run.
May combine two claims.
PremisecitationNotable CZE-MS examples include intact mass analysis of biopharmaceutical proteins and monoclonal antibodies, where complete baseline separation is often achieved.
“Notable examples of CZE-MS include the intact mass analysis of biopharmaceutical proteins11 and monoclonal antibodies22,68 where complete baseline separation is often achieved.”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [11] Bush DR, Zang L, Belov AM, Ivanov AR, Karger BL. High Resolution CZE-MS Quantitative Characterization of Intact Biopharmaceutical Proteins: Proteoforms of Interferon-beta1. Analytical chemistry. 2016; 88(2): 1138– 1146. 26641950 source
Not checked in the free run.
- cites [22] Han M, Rock BM, Pearson JT, Rock DA. Intact mass analysis of monoclonal antibodies by capillary electrophoresis-Mass spectrometry. Journal of chromatography B, Analytical technologies in the biomedical and life sciences. 2016; 1011: 24– 32. 26751590 source
Not checked in the free run.
- cites [68] Zhao Y, Sun L, Knierman MD, Dovichi NJ. Fast separation and analysis of reduced monoclonal antibodies with capillary zone electrophoresis coupled to mass spectrometry. Talanta. 2016; 148: 529– 533. 26653481 source
Not checked in the free run.
May combine two claims.
PremisecitationMulti-phosphorylated peptides were poorly retained on the reversed-phase LC-MS stationary phase, leading to fewer peptide identifications than in CE-MS analysis.
“These authors observed that multi-phosphorylated peptides were poorly retained on the stationary phase of a reversed-phase LC-MS method, resulting in a decreased number of peptide identification relative to the CE-MS analysis.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [84] Faserl K, Sarg B, Gruber P, Lindner HH. Investigating capillary electrophoresis-mass spectrometry for the analysis of common post-translational modifications. Electrophoresis. 2018; 39(9–10): 1208– 1215. 29389038 PMC6001557 source
Not checked in the free run.
May combine two claims.
PremisecitationIn the Zhang study, limitations included marginal identifications during the first 20 minutes and a dramatic reduction in identifications after 85 minutes.
“Despite the high number of identifications, some limitations were observed, including marginal identifications during the first 20 min of the separation, and a dramatic reduction in identifications after 85 min.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [46] Zhang Z, Hebert AS, Westphall MS, Qu Y, Coon JJ, Dovichi NJ. Production of Over 27 000 Peptide and Nearly 4400 Protein Identifications by Single-Shot Capillary-Zone Electrophoresis-Mass Spectrometry via Combination of a Very-Low-Electroosmosis Coated Capillary, a Third-Generation Electrokinetically-Pumped Sheath-Flow Nanospray Interface, an Orbitrap Fusion Lumos Tribrid Mass Spectrometer, and an Advanced-Peak-Determination Algorithm. Analytical chemistry. 2018; 90(20): 12090– 12093. 30179504 PMC6508074 source
Not checked in the free run.
May combine two claims.
PremisecitationLi and co-workers reported a bottom-up strategy combining CZE-MS and reversed-phase LC-MS data, which improved the number of identified unique peptides, with hydrophilic and basic low-molecular-weight peptides predominantly identified by CZE-MS.
“For instance, Li and co-workers reported a bottom-up strategy that combines the data from CZE-MS and reversed-phase LC-MS91. This combination resulted in an improved number of identified unique peptides where hydrophilic and basic peptides with low molecular weight were predominantly identified via CZE-MS.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [91] Li Y, Champion MM, Sun L, Champion PAD, Wojcik R, Dovichi NJ. Capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry as an alternative proteomics platform to ultraperformance liquid chromatography-electrospray ionization-tandem mass spectrometry for samples of intermediate complexity. Analytical chemistry. 2012; 84(3): 1617– 1622. 22182061 PMC3277681 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationAccording to modeling data, phosphorylation reduces a peptide's charge and thereby its electrophoretic mobility.
“According to this modeling data, phosphorylation reduces the charge of a peptide, thereby its electrophoretic mobility.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [86] Chen D, Ludwig KR, Krokhin OV, Capillary Zone Electrophoresis-Tandem Mass Spectrometry for Large-Scale Phosphoproteomics with the Production of over 11,000 Phosphopeptides from the Colon Carcinoma HCT116 Cell Line. Analytical chemistry. 2019; 91(3): 2201– 2208. 30624053 PMC6506858 source
Not checked in the free run.
May combine two claims.
PremisecitationCZE separation has frequently been used to analyze glycosylated peptides and glycans, and CZE via TDMS has been used for glycosylation characterization.
“CZE separation has frequently been used to analyze glycosylated peptides and glycans49,57,80,81 and CZE separation via TDMS was used for glycosylation characterization82.”
Quote in the paperNot a substantial claim0 of 5 sources checked- cites [49] Qu Y, Sun L, Zhu G, Zhang Z, Peuchen EH, Dovichi NJ. Sensitive and fast characterization of site-specific protein glycosylation with capillary electrophoresis coupled to mass spectrometry. Talanta. 2018; 179: 22– 27. 29310225 PMC5763510 source
Not checked in the free run.
- cites [57] Snyder CM, Zhou X, Karty JA, Fonslow BR, Novotny MV, Jacobson SC. Capillary electrophoresis-mass spectrometry for direct structural identification of serum N-glycans. Journal of chromatography A. 2017; 1523: 127– 139. 28989033 PMC5691604 source
Not checked in the free run.
- cites [80] Giorgetti J, D’Atri V, Canonge J, Monoclonal antibody N-glycosylation profiling using capillary electrophoresis - Mass spectrometry: Assessment and method validation. Talanta. 2018; 178: 530– 537. 29136858 source
Not checked in the free run.
- cites [81] Konermann L Addressing a Common Misconception: Ammonium Acetate as Neutral pH “Buffer” for Native Electrospray Mass Spectrometry. Journal of the American Society for Mass Spectrometry. 2017; 28(9): 1827– 1835. 28710594 source
Not checked in the free run.
- cites [82] Yang Y, Franc V, Heck AJR. Glycoproteomics: A Balance between High-Throughput and In-Depth Analysis. Trends in Biotechnology. 2017; 35(7): 598– 609. 28527536 source
Not checked in the free run.
May combine two claims.
PremisecitationPost-translational phosphorylation plays critical roles in biological systems and can influence the electrophoretic mobility of peptides.
“Post-translational phosphorylation plays critical roles in biological systems83 and it can also influence the electrophoretic mobility of peptides.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [83] Mou S, Sun L, Dovichi NJ. Accurate determination of peptide phosphorylation stoichiometry via automated diagonal capillary electrophoresis coupled with mass spectrometry: proof of principle. Analytical chemistry. 2013; 85(22): 10692– 10696. 24144020 PMC3873722 source
Not checked in the free run.
May combine two claims.
PremisecitationCZE has proven valuable for protein identification via bottom-up proteomics, where ultrasensitive and fast analysis can be obtained.
“CZE has also proven to be a valuable tool for protein identification via bottom-up proteomics where ultrasensitive and fast analysis can be obtained72–74.”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [72] Sun L, Zhu G, Zhao Y, Yan X, Mou S, Dovichi NJ. Ultrasensitive and fast bottom-up analysis of femtogram amounts of complex proteome digests. Angewandte Chemie (International ed in English). 2013; 52(51): 13661– 13664. 24173663 PMC3904452 source
Not checked in the free run.
- cites [73] Zhang Z, Dovichi NJ. Optimization of mass spectrometric parameters improve the identification performance of capillary zone electrophoresis for single-shot bottom-up proteomics analysis. Analytica chimica acta. 2018; 1001: 93– 99. 29291811 PMC6159893 source
Not checked in the free run.
- cites [74] Zhu G, Sun L, Heidbrink-Thompson J, Capillary zone electrophoresis tandem mass spectrometry detects low concentration host cell impurities in monoclonal antibodies. Electrophoresis. 2016; 37(4): 616– 622. 26530276 PMC4816075 source
Not checked in the free run.
May combine two claims.
PremisecitationLudwig and co-workers reported a CZE-MS approach that identified over 2,300 phosphorylated peptides in a single analysis, illustrating advantages of CZE over LC for PTM analysis.
“Ludwig and co-workers reported a CZE-MS approach that was able to identify over 2,300 phosphorylated peptides in a single analysis85, thus illustrating the advantages of CZE separation over LC for PTM analysis.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [85] Ludwig KR, Sun L, Zhu G, Dovichi NJ, Hummon AB. Over 2300 phosphorylated peptide identifications with single-shot capillary zone electrophoresis-tandem mass spectrometry in a 100 min separation. Analytical chemistry. 2015; 87(19): 9532– 9537. 26399161 PMC4605816 source
Not checked in the free run.
May combine two claims.
InterpretationcitationThe Yang et al. results demonstrated increased sensitivity over C18 ZipTip-only analysis and highlighted advantages of an LC-CZE-MS bottom-up approach.
“These results demonstrated an increase in sensitivity over analysis after separation using C18 ZipTip only, and highlighted the advantages of using a LC-CZE-MS bottom-up approach.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [47] Yang Z, Shen X, Chen D, Sun L. Microscale Reversed-Phase Liquid Chromatography/Capillary Zone Electrophoresis-Tandem Mass Spectrometry for Deep and Highly Sensitive Bottom-Up Proteomics: Identification of 7500 Proteins with Five Micrograms of an MCF7 Proteome Digest. Analytical chemistry. 2018; 90(17): 10479– 10486. 30102516 PMC6156779 source
Not checked in the free run.
May combine two claims.
PremisecitationGlycosylation is an important and common PTM, but its detailed characterization is challenging because of heterogeneity in localization and forms.
“Glycosylation is an important and common PTM in biological systems, but its detailed characterization is challenging because of its heterogeneity in localization and forms76–79.”
Quote in the paperNot a substantial claim0 of 4 sources checked- cites [76] Mechref Y, Novotny MV. Glycomic analysis by capillary electrophoresis-mass spectrometry. Mass spectrometry reviews. 2009; 28(2): 207– 222. 18973241 source
Not checked in the free run.
- cites [77] Jayo RG, Thaysen-Andersen M, Lindenburg PW, Simple capillary electrophoresis-mass spectrometry method for complex glycan analysis using a flow-through microvial interface. Analytical chemistry. 2014; 86(13): 6479– 6486. 24873509 source
Not checked in the free run.
- cites [78] Lu G, Crihfield CL, Gattu S, Veltri LM, Holland LA. Capillary Electrophoresis Separations of Glycans. Chemical reviews. 2018; 118(17): 7867– 7885. 29528644 PMC6135675 source
Not checked in the free run.
- cites [79] Mechref Y Analysis of glycans derived from glycoconjugates by capillary electrophoresis-mass spectrometry. Electrophoresis. 2011; 32(24): 3467– 3481. 22180203 PMC3360420 source
Not checked in the free run.
May combine two claims.
InterpretationreasoningAcetic acid increased protein migration time, which may be attributed to lower pH causing increased hydrodynamic protein radii, more protein unfolding, and reduced electroosmotic flow.
“The use of acetic acid also increased the migration time of the proteins, which might be attributed to the lower pH of acetic acid that resulted in an increase in hydrodynamics in protein radii, exacerbation of protein unfolding, and reduction of EOF.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [69] Lubeckyj RA, McCool EN, Shen X, Kou Q, Liu X, Sun L. Single-Shot Top-Down Proteomics with Capillary Zone Electrophoresis-Electrospray Ionization-Tandem Mass Spectrometry for Identification of Nearly 600 Escherichia coli Proteoforms. Analytical chemistry. 2017; 89(22): 12059– 12067. 29064224 PMC5726253 source
Not checked in the free run.
May combine two claims.
Premisenone givenHigh ionic strength in the BGE can increase diffusion of the sample zone and cause high current and temperature in the separation capillary, even though it helps avoid band broadening.
“Although a BGE with high ionic strength is useful to avoid band broadening, high ionic strength can increase the diffusion of the sample zone and lead to high current and temperature in the separation capillary.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationAdding organic solvents such as propan-2-ol to an acidic BGE enhances separation efficiency and MS detection, as demonstrated by the Yates group in top-down analysis of Pyrococcus furiosus proteins with a sheathless interface.
“Interestingly, addition of organic solvents (e.g., propan-2-ol) to an acidic BGE enhances the separation efficiency and MS detection, as demonstrated by Yates group in a top-down analysis of Pyrococcus furiosus proteins using a sheathless interface59.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [59] Han X, Wang Y, Aslanian A, In-line separation by capillary electrophoresis prior to analysis by top-down mass spectrometry enables sensitive characterization of protein complexes. Journal of proteome research. 2014; 13(12): 6078– 6086. 25382489 PMC4262260 source
Not checked in the free run.
May combine two claims.
PremisecitationA 130 nL pH junction injection of BSA identified 40 peptides and produced 70% coverage.
“In this study, a pH junction injection of 130 nL of BSA resulted in the identification of 40 peptides and produced 70% coverage.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [119] Zhu G, Sun L, Yan X, Dovichi NJ. Bottom-up proteomics of Escherichia coli using dynamic pH junction preconcentration and capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry. Analytical chemistry. 2014; 86(13): 6331– 6336. 24852005 PMC4082393 source
Not checked in the free run.
- Rests on an assumption: CE has very limited loading capacity, which can reduce sensitivity and peptide and protein identifications.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationcIEF has also been reported for analysis of other intact proteins.
“cIEF has been also reported for the analysis of other intact proteins94.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [94] Zhu G, Sun L, Dovichi NJ. Simplified capillary isoelectric focusing with chemical mobilization for intact protein analysis. Journal of separation science. 2017; 40(4): 948– 953. 27935257 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Premisenone givenAt pH below about 3.5, migration is predominantly influenced by basic residues.
“For instance, in a pH lower than ~3.5, migration is predominantly influenced by the basic residues.”
Quote in the paperNot a substantial claimMay combine two claims.
Premisenone givenAt low pH, free silanols in the capillary wall are protonated, and protein and peptide separation is enhanced by reduced electroosmotic flow and reduced electrostatic interactions.
“At low pH the free silanols in the capillary wall are protonated and the separation of proteins and peptides is enhanced due to a reduction of the electroosmotic flow (EOF) and reduction of electrostatic interactions.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Premisenone givencIEF is not compatible with a sheathless interface.
“Also, it is not compatible with a sheathless interface.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThirty proteins were identified from P. aeruginosa PA01 whole cell lysate using a PA coated capillary.
“In this study, 30 proteins were identified from P. aeruginosa PA01 whole cell lysate110.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [110] Li Y, Compton PD, Tran JC, Ntai I, Kelleher NL. Optimizing capillary electrophoresis for top-down proteomics of 30–80 kDa proteins. Proteomics. 2014; 14(10): 1158– 1164. 24596178 PMC4034378 source
Not checked in the free run.
May combine two claims.
PremisereasoningThe sheath-liquid interface is more flexible, and because acidic pH can be obtained from the sheath-liquid reservoir, the BGE pH range can vary between 1 and 8.
“Conversely, sheath-liquid interface is more flexible and an acidic pH can be obtained from the sheath-liquid reservoir, so the BGE pH range can vary between 1 and 8 units.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisereasoningPositively charged coatings require reversed polarity with negative voltage at the inlet, causing proteins and peptides to migrate opposite to EOF.
“The use of positively charged coatings requires the application of negative voltage on the inlet (reversed polarity); as a result, proteins and peptides will migrate in the opposite direction of the EOF.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisenone givenDynamic pH junction relies on preparing samples in a basic buffer, pressure injection into the capillary, and under an electric field negatively charged proteins or peptides migrating toward the proximal tip and being neutralized by an acidic BGE.
“This stacking technique relies on the preparation of samples in a basic buffer and injection (with pressure) into the separation capillary. Under application of an electric field, negatively charged proteins or peptides migrate toward the proximal tip of the capillary and are neutralized by an acidic BGE.”
Quote in the paperNot a substantial claim- Rests on an assumption: CE has very limited loading capacity, which can reduce sensitivity and peptide and protein identifications.
May combine two claims.
PremisecitationIn dynamic pH junction, a focused plug forms and target analytes become positively charged and migrate toward the ESI source.
“A focused plug is formed and target analytes become positively charged, migrating towards the ESI source25,118.”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [25] Sun L, Zhu G, Yan X, Capillary zone electrophoresis for bottom‐up analysis of complex proteomes. 2016; 16(2): 188– 196. PMC4771184 26508368 source
Not checked in the free run.
- cites [118] Zhu G, Sun L, Dovichi NJ. Dynamic pH junction preconcentration in capillary electrophoresis- electrospray ionization-mass spectrometry for proteomics analysis. The Analyst. 2016; 141(18): 5216– 5220. 27460877 PMC5007160 source
Not checked in the free run.
- Rests on an assumption: CE has very limited loading capacity, which can reduce sensitivity and peptide and protein identifications.
May combine two claims.
PremisecitationIn protein ESI-MS with holomyoglobin under native conditions, high charge states formed and their signal intensities increased with buffer ionic strength.
“As illustrated in Figure 6, high charge states (as in denaturing conditions) were formed in native conditions and their signal intensities increased proportionally to the increase in buffer ionic strength.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [101] Hedges JB, Vahidi S, Yue X, Konermann L. Effects of ammonium bicarbonate on the electrospray mass spectra of proteins: evidence for bubble-induced unfolding. Analytical chemistry. 2013; 85(13): 6469– 6476. 23724896 source
Not checked in the free run.
May combine two claims.
PremisecitationBare fused silica capillaries gave marginal separation efficiency for intact proteins and protein complexes because of protein adsorption, whereas neutral coated capillaries gave high separation efficiency by preventing adsorption.
“The bare fused silica capillary produced a marginal separation efficiency for intact proteins and protein complexes as a result of protein adsorption to the capillary wall, whereas the neutral coated capillary generated high separation efficiency by preventing protein adsorption35.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [35] Belov AM, Viner R, Santos MR, Analysis of Proteins, Protein Complexes, and Organellar Proteomes Using Sheathless Capillary Zone Electrophoresis - Native Mass Spectrometry. Journal of the American Society for Mass Spectrometry. 2017; 28(12): 2614– 2634. 28875426 PMC5709234 source
Not checked in the free run.
- Rests on an assumption: Hydrophobic and/or ionic interactions between proteins and capillary wall surfaces can increase protein retention or cause peak tailing.
- Rests on an assumption: Coated capillaries can limit protein adsorption on the capillary wall.
May combine two claims.
Premisenone givenAmmonium acetate dissolved in water can reach pH 6.8-7.4, although its buffering capacity is low, with buffer ranges at pH 3.8-5.8 and 8.2-10.20.
“Ammonium acetate can achieve a pH between 6.8 and 7.4 when dissolved in water and despite a low buffering capacity (ammonium acetate buffers in the pH ranges of 3.8–5.8 and 8.2–10.20, see Table 2), it is often used in native MS.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
InterpretationreasoningAcetonitrile may account for the fast separation and propan-2-ol may provide better resolution of degradation products.
“Acetonitrile might account for the fast separation and propan-2-ol may provide better resolution of the degradation products.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisereasoningIn CE-MS applications, the type of interface should be considered when choosing a BGE.
“In CE-MS applications, the type of interface should also be taken into consideration while choosing a BGE.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationcitationAdding organic solvent to the BGE reduces electroosmotic flow, which improves resolution.
“The addition of organic solvent to the BGE reduces the EOF, which results in improved resolution.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisereasoningBGE selection is most critical for a sheathless interface because the BGE is the only liquid during ESI and acidic pH is recommended to facilitate protein or peptide ionization.
“BGE selection is most critical for a sheathless interface because the BGE is the only liquid present during the ESI process and acidic pH is recommended to facilitate protein or peptide ionization efficiency.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationDai et al. reported cIEF-MS with a sheath-liquid interface for separation of an intact monoclonal antibody, resolving nine charge variants.
“cIEF-MS with a sheath-liquid interface has been used for the analysis of monoclonal antibodies, with Dai et al. reporting the separation of intact monoclonal antibody92. Resolving intact charge variant peaks is a noted challenge, but using this approach, nine charge variants were resolved.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [92] Dai J, Lamp J, Xia Q, Zhang Y. Capillary Isoelectric Focusing-Mass Spectrometry Method for the Separation and Online Characterization of Intact Monoclonal Antibody Charge Variants. Analytical chemistry. 2018; 90(3): 2246– 2254. 29272582 source
Not checked in the free run.
May combine two claims.
PremisereasoningNeutral polyacrylamide coating is widely used in proteomics because it eliminates EOF and maintains effective CE separations.
“Neutral coating with polyacrylamide is widely used in proteomics research due to its ability to eliminate EOF and maintain effective CE separations.”
Quote in the paperNot a substantial claim- Rests on an assumption: Coated capillaries can limit protein adsorption on the capillary wall.
- Rests on an assumption: EOF suppression or reversal can result in higher separation efficiency.
Probably not a substantial claim: may not pass S3 (load-bearing).
InterpretationreasoningThe high charge states seen with ammonium bicarbonate may result from bicarbonate anion destabilizing the protein and increasing its unfolding during ESI.
“This phenomenon might be attributed to the destabilization effects that are induced by the anion bicarbonate, exacerbating the propensity of the protein to unfold during ESI process.”
Quote in the paperNot a substantial claimMay combine two claims.
Premisenone givenMany preconcentration techniques for CE-MS enhance injection volumes and are based on electrophoretic stacking or chromatographic solid-phase extraction principles.
“Many preconcentration techniques to enhance injection volumes in CE-MS applications have been described, based on either electrophoretic (stacking) or chromatographic (solid-phase extraction (SPE)) principles.”
Quote in the paperNot a substantial claim- Rests on an assumption: CE has very limited loading capacity, which can reduce sensitivity and peptide and protein identifications.
May combine two claims.
Premiseown dataAcetate, bicarbonate, and formate salts each have more than one pKa value, so they can be used over more than one pH range.
“As can be observed in Table 2, these salts (acetate, bicarbonate, and formate) have more than one pKa, which allow their use in more than one pH range.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationcitationA CE-ESI-MS sheathless interface with ammonium bicarbonate preserved the native structure of Beta 2-microglobulin conformers and did not produce the high charge states promoted by ammonium bicarbonate, possibly because of lower ammonium bicarbonate concentration in the BGE.
“Using this set up, Bertoletti et al. were able to preserve protein structure in native conditions and they did not observe the high charge states that are promoted by ammonium bicarbonate, which might be attributed to the lower molar concentration of ammonium bicarbonate in the BGE.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [102] Bertoletti L, Schappler J, Colombo R, Evaluation of capillary electrophoresis-mass spectrometry for the analysis of the conformational heterogeneity of intact proteins using beta2-microglobulin as model compound. Analytica chimica acta. 2016; 945: 102– 109. 27968711 source
Not checked in the free run.
May combine two claims.
PremisecitationA two-plex CE-MS method for N-glycan quantification was linear and precise.
“The CE-MS method was found to be linear and precise.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [128] Varadi C, Mittermayr S, Millan-Martin S, Bones J. Quantitative twoplex glycan analysis using (12)C6 and (13)C6 stable isotope 2-aminobenzoic acid labelling and capillary electrophoresis mass spectrometry. Analytical and bioanalytical chemistry. 2016; 408(30): 8691– 8700. 27662881 source
Not checked in the free run.
May combine two claims.
InterpretationreasoningDespite more technical difficulties than LC-MS, CE-MS with improved instrumentation has outperformed conventional LC-based methods in some applications, such as separation of intact proteins and protein complexes.
“Despite susceptibility to more technical difficulties and issues than LC-MS, with improvements in instrumentation CE-MS has, in some applications, outperformed conventional LC-based methods (e.g., separation of intact proteins and protein complexes).”
Quote in the paperSubstantial claimMay combine two claims.
Interpretationnone givenBoth sheathless and sheath-liquid interfaces can achieve highly sensitive ionization at lower flow-rate than LC, reducing background noise and increasing MS detectability.
“Highly sensitive ionization efficiency can be achieved using both sheathless and sheath-liquid interfaces at lower flow-rate (in the separation capillary) than LC, which reduces background noise and increases MS detectability.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationCE-MS characterized and quantitated individual molecular proteoforms of interferon-β.
“Bush et al. characterized and quantitated individual molecular proteoforms of interferon-β111.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [111] Sanchez-Hernandez L, Montealegre C, Kiessig S, Moritz B, Neususs C. In-capillary approach to eliminate SDS interferences in antibody analysis by capillary electrophoresis coupled to mass spectrometry. Electrophoresis. 2017; 38(7): 1044– 1052. 28008632 source
Not checked in the free run.
May combine two claims.
InterpretationreasoningSPE-CE technology can be automated, and multistep elution CE can serve as a semi-two-dimensional separation method.
“This technology has the advantage that it can be automated and the multistep elution CE can be used as a semi-two-dimensional separation method.”
Quote in the paperNot a substantial claim- Rests on an assumption: CE has very limited loading capacity, which can reduce sensitivity and peptide and protein identifications.
May combine two claims.
PremisecitationOn-line SPE preconcentration with a sulfonate-silica hybrid SCX monolith and dynamic pH junction enabled microliter-level injections with separation efficiency over 25,000 theoretical plates.
“This approach enabled injections at μL levels with a separation efficiency of over 25,000 theoretical plates.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [124] Zhang Z, Sun L, Zhu G, Yan X, Dovichi NJ. Integrated strong cation-exchange hybrid monolith coupled with capillary zone electrophoresis and simultaneous dynamic pH junction for large-volume proteomic analysis by mass spectrometry. Talanta. 2015; 138: 117– 122. 25863379 PMC4394190 source
Not checked in the free run.
- Rests on an assumption: CE has very limited loading capacity, which can reduce sensitivity and peptide and protein identifications.
May combine two claims.
Premisenone givenTDMS can provide structural information on proteins covalently attached to other proteins, while native MS provides information on protein subunit arrangements via non-covalent interactions.
“In addition to a detailed proteoform characterization, TDMS can provide structural information of proteins covalently attached to other proteins while native MS provides a detailed information on protein subunit arrangements via non-covalent interactions.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationPreparing SCX and a neutral coated capillary sequentially in a single fused silica capillary eliminated the zero dead volume union and enhanced protein and peptide identifications compared to previous reports.
“The same group further eliminated the zero dead volume union by preparing SCX and the neutral coated capillary sequentially in a single fused silica capillary, which resulted in an enhanced protein and peptide identifications when compared to previous reports126.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [126] Zhang Z, Zhu G, Peuchen EH, Dovichi NJ. Preparation of linear polyacrylamide coating and strong cationic exchange hybrid monolith in a single capillary, and its application as an automated platform for bottom-up proteomics by capillary electrophoresis-mass spectrometry. Microchimica Acta. 2017; 184(3): 921– 925. source
Not checked in the free run.
- Rests on an assumption: CE has very limited loading capacity, which can reduce sensitivity and peptide and protein identifications.
May combine two claims.
PremisecitationcITP/CZE quantification of targeted BSA tryptic peptides had a quantitation limit of 10 pM and a coefficient of variation lower than 22%.
“They observed a quantitation limit of 10 pM with a CV lower than 22%121.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [121] Wang C, Lee CS, Smith RD, Tang KJAc. CITP/CZE-nanoESI-SRM MS via a novel sheathless interface for high sensitivity sample quantification. 2013; 85(15): 7308. PMC3744340 23789856 source
Not checked in the free run.
Probably not a substantial claim: may not pass S4 (based). May combine two claims.
Interpretationnone givenCross-linking and MS have been successfully used to interrogate protein structures, but CE-MS cross-linking reports are scarce.
“Cross-linking and MS have been successfully used to interrogate protein structures; however, cross-linking reports by CE-MS are scarce.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationcitationSample loading is the major drawback of CE and can be addressed using simple protocols, as shown in top-down and bottom-up applications.
“Sample loading is the major drawback of CE, which can be addressed using simple protocols, as demonstrated in top-down and bottom-up applications52,87.”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [52] McCool EN, Lubeckyj R, Shen X, Kou Q, Liu X, Sun L. Large-scale Top-down Proteomics Using Capillary Zone Electrophoresis Tandem Mass Spectrometry. Journal of visualized experiments: JoVE. 2018(140). PMC6235596 30417888 source
Not checked in the free run.
- cites [87] Wang Y, Fonslow BR, Wong CC, Nakorchevsky A, Yates JR 3rd. Improving the comprehensiveness and sensitivity of sheathless capillary electrophoresis-tandem mass spectrometry for proteomic analysis. Analytical chemistry. 2012; 84(20): 8505– 8513. 23004022 PMC3498465 source
Not checked in the free run.
- Rests on an assumption: CE has very limited loading capacity, which can reduce sensitivity and peptide and protein identifications.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Premisenone giventITP mixes the sample with high-mobility leading and low-mobility terminating electrolytes, generating a highly conductive zone when voltage is applied and concentrating proteins or peptides between the leading and terminating electrolytes.
“In this strategy, the sample is mixed with two electrolytes, one with very high mobility (leading) and one with very low mobility (terminating). These electrolytes generate a highly conductive zone when separation voltage is applied. Proteins or peptides are then concentrated into zones between the leading and terminating electrolytes.”
Quote in the paperNot a substantial claim- Rests on an assumption: CE has very limited loading capacity, which can reduce sensitivity and peptide and protein identifications.
May combine two claims.
PremisecitationReversed-phase SPE combined with tITP for a Pyrococcus furiosus tryptic digest gave low background noise and high sensitivity.
“Wang et al. used reversed-phase SPE in conjunction with tITP for sample concentration of a Pyrococcus furiosus tryptic digest, which resulted in low background noise and high sensitivity87.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [87] Wang Y, Fonslow BR, Wong CC, Nakorchevsky A, Yates JR 3rd. Improving the comprehensiveness and sensitivity of sheathless capillary electrophoresis-tandem mass spectrometry for proteomic analysis. Analytical chemistry. 2012; 84(20): 8505– 8513. 23004022 PMC3498465 source
Not checked in the free run.
- Rests on an assumption: CE has very limited loading capacity, which can reduce sensitivity and peptide and protein identifications.
Probably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenSeveral bottom-up strategies are available for protein quantification, including SILAC, iTRAQ, label-free, and ICAT.
“Several bottom-up strategies are available for protein quantification, including stable isotope labeling by amino acids in cell culture (SILAC), isobaric tag for relative and absolute quantitation (iTRAQ), label-free, and isotope-coded affinity tags (ICAT).”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationreasoningImprovements in CE-MS interfaces have enhanced robustness and reproducibility, leading to confident identification and characterization of peptides, cellular proteins, PTMs, and protein complexes.
“Improvements in interfaces have enhanced the robustness and reproducibility of CE-MS methods, resulting in highly confident identification and characterization of peptides, cellular proteins, PTMs, and protein complexes.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationQuantitative parallel reaction monitoring of peptide abundance had a relative standard deviation of migration time lower than 4% and a relative standard deviation of fragment ion of approximately 20%.
“Sun and co-workers described a quantitative parallel reaction monitoring of peptide abundance where the relative standard deviation (RSD) of the migration time was lower than 4% and the RSD of the fragment ion was approximately 20%132.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [132] Sun L, Zhu G, Mou S, Zhao Y, Champion MM, Dovichi NJ. Capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry for quantitative parallel reaction monitoring of peptide abundance and single-shot proteomic analysis of a human cell line. Journal of chromatography A. 2014; 1359: 303– 308. 25082526 PMC4141985 source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
Premisenone givenTransient isotachophoresis is a less common stacking approach for preconcentration of peptides and proteins in proteomics.
“Transient isotachophoresis (tITP) is a less common stacking approach for preconcentration of peptides and proteins in proteomics research.”
Quote in the paperNot a substantial claim- Rests on an assumption: CE has very limited loading capacity, which can reduce sensitivity and peptide and protein identifications.
May combine two claims.
InterpretationreasoningTDMS and native MS can be complementary at several levels and merged to provide comprehensive protein structural information.
“These individual features suggest that TDMS and native MS can be complementary at several levels and can be merged to provide comprehensive protein structural information.”
Quote in the paperSubstantial claim
The paper relies on this without support.
Progress in proteomics research has created a demand for powerful analytical tools with high separation efficiency and sensitivity for confident identification and quantification of proteins, PTMs, and protein complexes in cells and tissues.
“Progress in proteomics research has led to a demand for powerful analytical tools with high separation efficiency and sensitivity for confident identification and quantification of proteins, posttranslational modifications (PTMs), and protein complexes expressed in cells and tissues.”
The paper relies on this without support.
This demand has significantly increased interest in CE-MS in the past few years.
“This demand has significantly increased interest in capillary electrophoresis-mass spectrometry (CE-MS) in the past few years.”
The paper relies on this without support.
The most common CE-MS technique used in proteomics is capillary zone electrophoresis coupled with electrospray ionization.
“The most common CE-MS technique used in the proteomics field is capillary zone electrophoresis (CZE) coupled with electrospray ionization (ESI).”
The paper relies on this without support.
Most proteins are assembled into protein complexes to achieve functional activity.
“Most proteins are assembled into protein complexes to achieve functional activity, but it is still unclear how these macromolecular complexes are formed.”
The paper relies on this without support.
Residue shape and size have little effect on the electrophoretic mobility of a peptide.
“Since it has been generally accepted that residue shape and size have little effect on the electrophoretic mobility of a peptide, these models are based on the use of BGE pH, side group pKa, N-terminal amine, and C-terminal acid to determine the charge of the peptide.”
The paper relies on this without support.
In CZE, band broadening is caused only by longitudinal diffusion.
“In CZE, band broadening is only caused by longitudinal diffusion.”
The paper relies on this without support.
CE has very limited loading capacity, which can reduce sensitivity and peptide and protein identifications.
“The loading capacity of CE is very limited, which can adversely affect the sensitivity of the method and reduce peptide and protein identifications.”
The paper relies on this without support.
Proteins have low diffusion coefficients and should therefore produce very high separation efficiency in CE.
“Theoretically, since proteins have low diffusion coefficients, they should produce very high separation efficiency in CE.”
The paper relies on this without support.
Hydrophobic and/or ionic interactions between proteins and capillary wall surfaces can increase protein retention or cause peak tailing.
“However, hydrophobic and/or ionic interactions between protein and capillary wall surfaces can lead to increased protein retention in the capillary, or to a lesser extent, peak tailing.”
The paper relies on this without support.
Coated capillaries can limit protein adsorption on the capillary wall.
“Coated capillaries can be used to limit protein adsorption on the capillary wall.”
The paper relies on this without support.
EOF suppression or reversal can result in higher separation efficiency.
“EOF suppression or reversal can result in higher separation efficiency, and the EOF can be regulated by the capillary coating.”
The paper relies on this without support.
In native ESI-MS, environmentally induced pH changes can perturb tertiary and quaternary conformations of protein complexes in solution.
“In native ESI-MS, protein complexes are transferred from solution to the gas phase and environmentally induced changes in pH can perturb their tertiary and quaternary conformations while in solution.”
The paper relies on this without support.
High ionic strength can increase diffusion of the sample zone and lead to high current and temperature in the separation capillary.
“Although a BGE with high ionic strength is useful to avoid band broadening, high ionic strength can increase the diffusion of the sample zone and lead to high current and temperature in the separation capillary.”
The paper relies on this without support.
Quantitative information is critical to gain insights into clinical disorders.
“In proteomics research, quantitative information is critical to gain insights into clinical disorders.”
The paper relies on this without support.
Quantification via CE-MS is particularly valuable for clinical studies where samples are often obtained in limited quantities.
“Quantification via CE-MS is particularly valuable for clinical studies where samples are often obtained in limited quantities.”
The paper relies on this without support.
Top-down analysis provides quantitative information on diverse proteoforms that are often missed in bottom-up approaches.
“Top-down analysis provides quantitative information on diverse proteoforms that are often missed in bottom-up approaches.”
The paper relies on this without support.
No single dimension can provide complete reduction of sample complexity.
“No single dimension, however, can provide complete reduction of sample complexity.”
The paper relies on this without support.
Multidimensional separations are the most effective strategy for improving peak capacity and reducing sample complexity.
“Rather, utilization of multidimensional separations is the most effective strategy for improving peak capacity and reducing sample complexity.”
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Sheathflow and sheathless interfaces have enabled facile coupling of CZE to MS.
“The development of sheathflow and sheathless interfaces have enabled facile coupling of CZE to MS [73].”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [73]
CZE has recently shown promise as an alternative or complementary front-end separation due to inherent sensitivity and peak capacity.
“Capillary zone electrophoresis (CZE) has recently shown great promise as an alternative or complementary front-end separation due to its inherent sensitivity and peak capacity [73].”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [73]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Belov study is attributed to a reference by different authors
MinorThe text attributes reference 34 to Belov and co-workers, but reference 34 lists Chen and co-workers and describes a different study.
“An early report for analysis of protein complexes via CZE-MS was described by Belov and co-workers34.”
“34. Chen D, Gomes F, Abeykoon D, Top-Down Analysis of Branched Proteins Using Mass Spectrometry.”
SPE study is attributed to Wang instead of the cited authors
MinorThe text names Wang et al. for the study cited as reference 123, but that reference lists Tong et al.
“Sample preconcentration using a chromatographic principle such as SPE was used by Wang et al. where large sample volumes can be trapped on reversed-phase media and eluted using an elution buffer prior to CE separation123.”
“123. Tong W, Link A, Eng JK, Yates JR 3rd. Identification of proteins in complexes by solid-phase microextraction/multistep elution/capillary electrophoresis/tandem mass spectrometry.”
Cites
Mass-spectrometric exploration of proteome structure and function
Aebersold, R., & Mann, M. (2016) · Nature · doi:10.1038/nature19949 · Cited by 2,334 · see citing works
Proteoform: a single term describing protein complexity
The Consortium for Top Down Proteomics, Smith, L. M., & Kelleher, N. L. (2013) · Nature Methods · doi:10.1038/nmeth.2369 · Cited by 1,528 · see citing works
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491 · see citing works
Self-citationProteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078 · see citing works
Self-citationHow many human proteoforms are there?
Aebersold, R., Agar, J. N., Amster, I. J., Baker, M. S., Bertozzi, C. R., Boja, E. S., Costello, C. E., Cravatt, B. F., Fenselau, C., Garcia, B. A., et al. (2018) · Nature Chemical Biology · doi:10.1038/nchembio.2576 · Cited by 907 · see citing works
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905 · see citing works
Native Mass Spectrometry: What is in the Name?
Leney, A. C., & Heck, A. J. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1545-3 · Cited by 602 · see citing works
Progress in Top-Down Proteomics and the Analysis of Proteoforms
Toby, T. K., Fornelli, L., & Kelleher, N. L. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041550 · Cited by 576 · see citing works
Top Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507 · see citing works
Mass spectrometry in high-throughput proteomics: ready for the big time
Nilsson, T., Mann, M., Aebersold, R., Yates, J. R., Bairoch, A., & Bergeron, J. J. M. (2010) · Nature Methods · doi:10.1038/nmeth0910-681 · Cited by 470 · see citing works
Self-citationLi, H., Nguyen, H. H., Ogorzalek Loo, R. R., Campuzano, I. D. G., & Loo, J. A. (2018) · Nature Chemistry · doi:10.1038/nchem.2908 · Cited by 249 · see citing works
Konermann, L. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1739-3 · Cited by 243 · see citing works
Wojcik, R., Dada, O. O., Sadilek, M., & Dovichi, N. J. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4672 · Cited by 234 · see citing works
Sun, L., Zhu, G., Zhang, Z., Mou, S., & Dovichi, N. J. (2015) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b00100 · Cited by 216 · see citing works
Lombard‐Banek, C., Moody, S. A., & Nemes, P. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201510411 · Cited by 214 · see citing works
Stolz, A., Jooß, K., Höcker, O., Römer, J., Schlecht, J., & Neusüß, C. (2019) · ELECTROPHORESIS · doi:10.1002/elps.201800331 · Cited by 214 · see citing works
Ultrasensitive and Fast Bottom‐up Analysis of Femtogram Amounts of Complex Proteome Digests
Sun, L., Zhu, G., Zhao, Y., Yan, X., Mou, S., & Dovichi, N. J. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201308139 · Cited by 212 · see citing works
Top-Down Proteomics: Ready for Prime Time?
Chen, B., Brown, K. A., Lin, Z., & Ge, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04747 · Cited by 210 · see citing works
Protein separation by capillary gel electrophoresis: A review
Zhu, Z., Lu, J. J., & Liu, S. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.10.022 · Cited by 202 · see citing works
Mischak, H., Coon, J. J., Novak, J., Weissinger, E. M., Schanstra, J. P., & Dominiczak, A. F. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20205 · Cited by 193 · see citing works
Capillary electrophoresis–mass spectrometry for the analysis of intact proteins
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.048 · Cited by 185 · see citing works
Capillary Electrophoresis Separations of Glycans
Lu, G., Crihfield, C. L., Gattu, S., Veltri, L. M., & Holland, L. A. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00669 · Cited by 174 · see citing works
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2013) · Analytical Chemistry · doi:10.1021/ac303158f · Cited by 149 · see citing works
Wang, Y., Fonslow, B. R., Wong, C. C. L., Nakorchevsky, A., & Yates, J. R. (2012) · Analytical Chemistry · doi:10.1021/ac301091m · Cited by 144 · see citing works
Self-citationTong, W., Link, A., Eng, J. K., & Yates, J. R. (1999) · Analytical Chemistry · doi:10.1021/ac9901182 · Cited by 143 · see citing works
Self-citationRedman, E. A., Batz, N. G., Mellors, J. S., & Ramsey, J. M. (2015) · Analytical Chemistry · doi:10.1021/ac503964j · Cited by 136 · see citing works
Lermyte, F., Tsybin, Y. O., O’Connor, P. B., & Loo, J. A. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02201-x · Cited by 132 · see citing works
The Revolution and Evolution of Shotgun Proteomics for Large-Scale Proteome Analysis
Yates, J. R. (2013) · Journal of the American Chemical Society · doi:10.1021/ja3094313 · Cited by 131 · see citing works
Self-citationToward an Optimized Workflow for Middle-Down Proteomics
Cristobal, A., Marino, F., Post, H., van den Toorn, H. W. P., Mohammed, S., & Heck, A. J. R. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03756 · Cited by 130 · see citing works
Lombard-Banek, C., Moody, S. A., Manzini, M. C., & Nemes, P. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b00345 · Cited by 130 · see citing works
Li, Y., Champion, M. M., Sun, L., Champion, P. A. D., Wojcik, R., & Dovichi, N. J. (2012) · Analytical Chemistry · doi:10.1021/ac202899p · Cited by 128 · see citing works
Dai, J., Lamp, J., Xia, Q., & Zhang, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04608 · Cited by 123 · see citing works
Glycoproteomics: A Balance between High-Throughput and In-Depth Analysis
Yang, Y., Franc, V., & Heck, A. J. R. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2017.04.010 · Cited by 122 · see citing works
McCool, E. N., Lubeckyj, R. A., Shen, X., Chen, D., Kou, Q., Liu, X., & Sun, L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00693 · Cited by 117 · see citing works
Hedges, J. B., Vahidi, S., Yue, X., & Konermann, L. (2013) · Analytical Chemistry · doi:10.1021/ac401020s · Cited by 109 · see citing works
Glycomic analysis by capillary electrophoresis–mass spectrometry
Mechref, Y., & Novotny, M. V. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20196 · Cited by 105 · see citing works
Zhu, G., Sun, L., Yan, X., & Dovichi, N. J. (2013) · Analytical Chemistry · doi:10.1021/ac303750g · Cited by 103 · see citing works
Zhao, Z., Malik, A., & Lee, M. L. (1993) · Analytical Chemistry · doi:10.1021/ac00068a008 · Cited by 102 · see citing works
Kellie, J. F., Tran, J. C., Lee, J. E., Ahlf, D. R., Thomas, H. M., Ntai, I., Catherman, A. D., Durbin, K. R., Zamdborg, L., Vellaichamy, A., et al. (2010) · Molecular BioSystems · doi:10.1039/c000896f · Cited by 99 · see citing works
Recent advances in CE‐MS coupling: Instrumentation, methodology, and applications
Týčová, A., Ledvina, V., & Klepárník, K. (2017) · ELECTROPHORESIS · doi:10.1002/elps.201600366 · Cited by 99 · see citing works
Belov, A. M., Viner, R., Santos, M. R., Horn, D. M., Bern, M., Karger, B. L., & Ivanov, A. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1781-1 · Cited by 97 · see citing works
<scp>CE</scp>‐<scp>MS</scp> for the analysis of intact proteins 2010–2012
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200439 · Cited by 96 · see citing works
Lubeckyj, R. A., McCool, E. N., Shen, X., Kou, Q., Liu, X., & Sun, L. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02532 · Cited by 96 · see citing works
Optimizing capillary electrophoresis for top‐down proteomics of 30–80 kDa proteins
Li, Y., Compton, P. D., Tran, J. C., Ntai, I., & Kelleher, N. L. (2014) · PROTEOMICS · doi:10.1002/pmic.201300381 · Cited by 95 · see citing works
Zhong, X., Chen, Z., Snovida, S., Liu, Y., Rogers, J. C., & Li, L. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01835 · Cited by 92 · see citing works
Capillary electrophoresis applied to proteomic analysis
Fonslow, B. R., & Yates III, J. R. (2009) · Journal of Separation Science · doi:10.1002/jssc.200800592 · Cited by 92 · see citing works
Self-citationBush, D. R., Zang, L., Belov, A. M., Ivanov, A. R., & Karger, B. L. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03218 · Cited by 92 · see citing works
Zhu, G., Sun, L., & Dovic̀hi, N. J. (2015) · Talanta · doi:10.1016/j.talanta.2015.06.003 · Cited by 91 · see citing works
Gahoual, R., Burr, A., Busnel, J.-M., Kuhn, L., Hammann, P., Beck, A., François, Y.-N., & Leize-Wagner, E. (2013) · mAbs · doi:10.4161/mabs.23995 · Cited by 90 · see citing works
Belov, A. M., Zang, L., Sebastiano, R., Santos, M. R., Bush, D. R., Karger, B. L., & Ivanov, A. R. (2018) · ELECTROPHORESIS · doi:10.1002/elps.201800067 · Cited by 88 · see citing works
CE–MS for proteomics: Advances in interface development and application
Ramautar, R., Heemskerk, A. A. M., Hensbergen, P. J., Deelder, A. M., Busnel, J.-M., & Mayboroda, O. A. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.04.050 · Cited by 86 · see citing works
Intact mass analysis of monoclonal antibodies by capillary electrophoresis—Mass spectrometry
Han, M., Rock, B. M., Pearson, J. T., & Rock, D. A. (2016) · Journal of Chromatography B · doi:10.1016/j.jchromb.2015.12.045 · Cited by 82 · see citing works
Jooß, K., Hühner, J., Kiessig, S., Moritz, B., & Neusüß, C. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-017-0542-0 · Cited by 79 · see citing works
Zhu, G., Sun, L., Yan, X., & Dovichi, N. J. (2014) · Analytical Chemistry · doi:10.1021/ac5004486 · Cited by 78 · see citing works
Shen, X., Kou, Q., Guo, R., Yang, Z., Chen, D., Liu, X., Hong, H., & Sun, L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b02725 · Cited by 78 · see citing works
Han, X., Wang, Y., Aslanian, A., Bern, M., Lavallée-Adam, M., & Yates, J. R. (2014) · Analytical Chemistry · doi:10.1021/ac503439n · Cited by 77 · see citing works
Self-citationCE‐MS‐based proteomics in biomarker discovery and clinical application
Pontillo, C., Filip, S., Borràs, D. M., Mullen, W., Vlahou, A., & Mischak, H. (2015) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201400115 · Cited by 77 · see citing works
Sarg, B., Faserl, K., Kremser, L., Halfinger, B., Sebastiano, R., & Lindner, H. H. (2013) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m112.024109 · Cited by 76 · see citing works
Kammeijer, G. S. M., Kohler, I., Jansen, B. C., Hensbergen, P. J., Mayboroda, O. A., Falck, D., & Wuhrer, M. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b00479 · Cited by 74 · see citing works
Lubeckyj, R. A., Basharat, A. R., Shen, X., Liu, X., & Sun, L. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02167-w · Cited by 72 · see citing works
Han, X., Wang, Y., Aslanian, A., Fonslow, B., Graczyk, B., Davis, T. N., & Yates, J. R. (2014) · Journal of Proteome Research · doi:10.1021/pr500971h · Cited by 72 · see citing works
Self-citationZhang, Z., Yan, X., Sun, L., Zhu, G., & Dovichi, N. J. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00789 · Cited by 67 · see citing works
Giorgetti, J., D’Atri, V., Canonge, J., Lechner, A., Guillarme, D., Colas, O., Wagner-Rousset, E., Beck, A., Leize-Wagner, E., & François, Y.-N. (2018) · Talanta · doi:10.1016/j.talanta.2017.09.083 · Cited by 65 · see citing works
Analysis of glycans derived from glycoconjugates by capillary electrophoresis‐mass spectrometry
Mechref, Y. (2011) · ELECTROPHORESIS · doi:10.1002/elps.201100342 · Cited by 64 · see citing works
Haselberg, R., De Vijlder, T., Heukers, R., Smit, M. J., Romijn, E. P., Somsen, G. W., & Domínguez-Vega, E. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.08.024 · Cited by 64 · see citing works
Capillary zone electrophoresis-mass spectrometry for bottom-up proteomics
Zhang, Z., Qu, Y., & Dovichi, N. J. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.08.008 · Cited by 61 · see citing works
Zhao, Y., Sun, L., Zhu, G., & Dovichi, N. J. (2016) · Journal of Proteome Research · doi:10.1021/acs.jproteome.6b00493 · Cited by 61 · see citing works
CE–ESI‐MS for bottom‐up proteomics: Advances in separation, interfacing and applications
Heemskerk, A. A. M., Deelder, A. M., & Mayboroda, O. A. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21432 · Cited by 61 · see citing works
Capillary electrophoresis–mass spectrometry for direct structural identification of serum N-glycans
Snyder, C. M., Zhou, X., Karty, J. A., Fonslow, B. R., Novotny, M. V., & Jacobson, S. C. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.09.009 · Cited by 58 · see citing works
Quantitative Proteomics Using Ultralow Flow Capillary Electrophoresis–Mass Spectrometry
Faserl, K., Kremser, L., Müller, M., Teis, D., & Lindner, H. H. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00312 · Cited by 57 · see citing works
Zhao, Y., Sun, L., Champion, M. M., Knierman, M. D., & Dovichi, N. J. (2014) · Analytical Chemistry · doi:10.1021/ac500092q · Cited by 56 · see citing works
Ludwig, K. R., Sun, L., Zhu, G., Dovichi, N. J., & Hummon, A. B. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02457 · Cited by 56 · see citing works
Zhao, Y., Riley, N. M., Sun, L., Hebert, A. S., Yan, X., Westphall, M. S., Rush, M. J. P., Zhu, G., Champion, M. M., Medie, F. M., et al. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00883 · Cited by 55 · see citing works
Höcker, O., Montealegre, C., & Neusüß, C. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1179-3 · Cited by 55 · see citing works
Guo, X., Fillmore, T. L., Gao, Y., & Tang, K. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04912 · Cited by 54 · see citing works
Jayo, R. G., Thaysen-Andersen, M., Lindenburg, P. W., Haselberg, R., Hankemeier, T., Ramautar, R., & Chen, D. D. Y. (2014) · Analytical Chemistry · doi:10.1021/ac5010212 · Cited by 54 · see citing works
Predicting Electrophoretic Mobility of Tryptic Peptides for High-Throughput CZE-MS Analysis
Krokhin, O. V., Anderson, G., Spicer, V., Sun, L., & Dovichi, N. J. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04544 · Cited by 53 · see citing works
Zhang, Z., Sun, L., Zhu, G., Yan, X., & Dovichi, N. J. (2015) · Talanta · doi:10.1016/j.talanta.2015.01.040 · Cited by 53 · see citing works
Zhu, G., Sun, L., & Dovichi, N. J. (2016) · The Analyst · doi:10.1039/c6an01140c · Cited by 52 · see citing works
Whitmore, C. D., & Gennaro, L. A. (2012) · Electrophoresis · doi:10.1002/elps.201200066 · Cited by 49 · see citing works
Zhao, Y., Sun, L., Knierman, M. D., & Dovichi, N. J. (2016) · Talanta · doi:10.1016/j.talanta.2015.11.020 · Cited by 49 · see citing works
Standard Proteoforms and Their Complexes for Native Mass Spectrometry
Schachner, L. F., Ives, A. N., McGee, J. P., Melani, R. D., Kafader, J. O., Compton, P. D., Patrie, S. M., & Kelleher, N. L. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02191-w · Cited by 48 · see citing works
Evaluation of a sheathless nanospray interface based on a porous tip sprayer for CE‐ESI‐MS coupling
Bonvin, G., Veuthey, J., Rudaz, S., & Schappler, J. (2012) · ELECTROPHORESIS · doi:10.1002/elps.201100461 · Cited by 48 · see citing works
Chen, D., Shen, X., & Sun, L. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.01.037 · Cited by 47 · see citing works
Dai, J., & Zhang, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04396 · Cited by 46 · see citing works
Wang, C., Lee, C. S., Smith, R. D., & Tang, K. (2013) · Analytical Chemistry · doi:10.1021/ac401202c · Cited by 46 · see citing works
Mokaddem, M., Gareil, P., Belgaied, J., & Varenne, A. (2009) · ELECTROPHORESIS · doi:10.1002/elps.200800480 · Cited by 45 · see citing works
Krenkova, J., & Foret, F. (2012) · PROTEOMICS · doi:10.1002/pmic.201200140 · Cited by 44 · see citing works
Capillary electrophoresis with Orbitrap-Velos mass spectrometry detection
Wojcik, R., Li, Y., MacCoss, M. J., & Dovichi, N. J. (2012) · Talanta · doi:10.1016/j.talanta.2011.10.048 · Cited by 43 · see citing works
Heemskerk, A. A. M., Wuhrer, M., Busnel, J., Koeleman, C. A. M., Selman, M. H. J., Vidarsson, G., Kapur, R., Schoenmaker, B., Derks, R. J. E., Deelder, A. M., et al. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200357 · Cited by 43 · see citing works
Yang, Z., Shen, X., Chen, D., & Sun, L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b02466 · Cited by 43 · see citing works
Biacchi, M., Said, N., Beck, A., Leize-Wagner, E., & François, Y.-N. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.02.064 · Cited by 41 · see citing works
Capillary zone electrophoresis for bottom‐up analysis of complex proteomes
Sun, L., Zhu, G., Yan, X., Zhang, Z., Wojcik, R., Champion, M. M., & Dovichi, N. J. (2016) · PROTEOMICS · doi:10.1002/pmic.201500339 · Cited by 41 · see citing works
Jooß, K., Meckelmann, S. W., Klein, J., Schmitz, O. J., & Neusüß, C. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1515-7 · Cited by 41 · see citing works
Qu, Y., Sun, L., Zhang, Z., & Dovichi, N. J. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03912 · Cited by 40 · see citing works
Váradi, C., Mittermayr, S., Millán-Martín, S., & Bones, J. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9935-8 · Cited by 40 · see citing works
Schiavone, N. M., Sarver, S. A., Sun, L., Wojcik, R., & Dovichi, N. J. (2015) · Journal of Chromatography B · doi:10.1016/j.jchromb.2015.04.001 · Cited by 39 · see citing works
Wang, C., Lee, C. S., Smith, R. D., & Tang, K. (2012) · Analytical Chemistry · doi:10.1021/ac302616m · Cited by 38 · see citing works
Faserl, K., Sarg, B., Gruber, P., & Lindner, H. H. (2018) · ELECTROPHORESIS · doi:10.1002/elps.201700437 · Cited by 38 · see citing works
Strategies for analysis of isomeric peptides
Jansson, E. T. (2017) · Journal of Separation Science · doi:10.1002/jssc.201700852 · Cited by 38 · see citing works
Urinary CE-MS peptide marker pattern for detection of solid tumors
Belczacka, I., Latosinska, A., Siwy, J., Metzger, J., Merseburger, A. S., Mischak, H., Vlahou, A., Frantzi, M., & Jankowski, V. (2018) · Scientific Reports · doi:10.1038/s41598-018-23585-y · Cited by 37 · see citing works
Giménez, E., Ramos‐Hernan, R., Benavente, F., Barbosa, J., & Sanz‐Nebot, V. (2011) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5114 · Cited by 36 · see citing works
Medina-Casanellas, S., Domínguez-Vega, E., Benavente, F., Sanz-Nebot, V., Somsen, G. W., & de Jong, G. J. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.12.080 · Cited by 36 · see citing works
Black, W. A., Stocks, B. B., Mellors, J. S., Engen, J. R., & Ramsey, J. M. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01179 · Cited by 35 · see citing works
Zhu, G., Sun, L., Heidbrink‐Thompson, J., Kuntumalla, S., Lin, H., Larkin, C. J., McGivney, J. B., & Dovichi, N. J. (2016) · ELECTROPHORESIS · doi:10.1002/elps.201500301 · Cited by 34 · see citing works
Chen, D., Ludwig, K. R., Krokhin, O. V., Spicer, V., Yang, Z., Shen, X., Hummon, A. B., & Sun, L. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04770 · Cited by 34 · see citing works
Nguyen, T. T. T. N., Petersen, N. J., & Rand, K. D. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.07.002 · Cited by 33 · see citing works
Sun, L., Zhu, G., Mou, S., Zhao, Y., Champion, M. M., & Dovic̀hi, N. J. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.07.024 · Cited by 31 · see citing works
Zhang, Z., Hebert, A. S., Westphall, M. S., Qu, Y., Coon, J. J., & Dovichi, N. J. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b02991 · Cited by 30 · see citing works
Qu, Y., Sun, L., Zhu, G., Zhang, Z., Peuchen, E. H., & Dovichi, N. J. (2018) · Talanta · doi:10.1016/j.talanta.2017.10.015 · Cited by 30 · see citing works
Peuchen, E. H., Zhu, G., Sun, L., & Dovichi, N. J. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-0122-8 · Cited by 30 · see citing works
Recent advances of capillary electrophoresis-mass spectrometry instrumentation and methodology
Jiang, Y., He, M.-Y., Zhang, W.-J., Luo, P., Guo, D., Fang, X., & Xu, W. (2017) · Chinese Chemical Letters · doi:10.1016/j.cclet.2017.05.008 · Cited by 30 · see citing works
Boley, D. A., Zhang, Z., & Dovichi, N. J. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.07.022 · Cited by 29 · see citing works
Sánchez‐Hernández, L., Montealegre, C., Kiessig, S., Moritz, B., & Neusüß, C. (2017) · ELECTROPHORESIS · doi:10.1002/elps.201600464 · Cited by 29 · see citing works
McCool, E. N., Lodge, J. M., Basharat, A. R., Liu, X., Coon, J. J., & Sun, L. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02206-6 · Cited by 28 · see citing works
Large-scale Top-down Proteomics Using Capillary Zone Electrophoresis Tandem Mass Spectrometry
McCool, E. N., Lubeckyj, R., Shen, X., Kou, Q., Liu, X., & Sun, L. (2018) · Journal of Visualized Experiments · doi:10.3791/58644 · Cited by 26 · see citing works
Marie, A.-L., Dominguez-Vega, E., Saller, F., Plantier, J.-L., Urbain, R., Borgel, D., Tran, N. T., Somsen, G. W., & Taverna, M. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.10.016 · Cited by 26 · see citing works
Yan, X., Sun, L., Zhu, G., Cox, O. F., & Dovic̀hi, N. J. (2016) · PROTEOMICS · doi:10.1002/pmic.201600262 · Cited by 26 · see citing works
Bertoletti, L., Schappler, J., Colombo, R., Rudaz, S., Haselberg, R., Domínguez-Vega, E., Raimondi, S., Somsen, G. W., & De Lorenzi, E. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.10.010 · Cited by 25 · see citing works
Zhang, Z., Zhu, G., Peuchen, E. H., & Dovichi, N. J. (2017) · Microchimica Acta · doi:10.1007/s00604-017-2084-8 · Cited by 24 · see citing works
Simplified capillary isoelectric focusing with chemical mobilization for intact protein analysis
Zhu, G., Sun, L., & Dovichi, N. J. (2017) · Journal of Separation Science · doi:10.1002/jssc.201601051 · Cited by 23 · see citing works
Zhang, Z., Albanetti, T., Linkous, T., Larkin, C. J., Schoner, R., McGivney, J. B., & Dovichi, N. J. (2017) · ELECTROPHORESIS · doi:10.1002/elps.201600390 · Cited by 23 · see citing works
Mou, S., Sun, L., & Dovichi, N. J. (2013) · Analytical Chemistry · doi:10.1021/ac402858a · Cited by 22 · see citing works
Zhang, Z., Hebert, A. S., Westphall, M. S., Coon, J. J., & Dovichi, N. J. (2019) · Journal of Proteome Research · doi:10.1021/acs.jproteome.9b00244 · Cited by 22 · see citing works
Zhang, Z., & Dovichi, N. J. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.11.023 · Cited by 20 · see citing works
Dada, O. O., Zhao, Y., Jaya, N., & Salas-Solano, O. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03405 · Cited by 20 · see citing works
Kahle, J., Stein, M., & Wätzig, H. (2019) · ELECTROPHORESIS · doi:10.1002/elps.201900162 · Cited by 20 · see citing works
Heart‐cut nano‐LC–CZE–MS for the characterization of proteins on the intact level
Jooß, K., Scholz, N., Meixner, J., & Neusüß, C. (2019) · ELECTROPHORESIS · doi:10.1002/elps.201800411 · Cited by 19 · see citing works
Partyka, J., Krenkova, J., Cmelik, R., & Foret, F. (2018) · Journal of Chromatography A · doi:10.1016/j.chroma.2018.05.030 · Cited by 19 · see citing works
Dominguez-Vega, E., De Vijlder, T., Romijn, E. P., & Somsen, G. W. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.06.021 · Cited by 19 · see citing works
Ali, F., & Cheong, W. J. (2015) · Journal of Separation Science · doi:10.1002/jssc.201500765 · Cited by 18 · see citing works
The Role of Mass Spectrometry in Structural Studies of Flavin-Based Electron Bifurcating Enzymes
Tokmina-Lukaszewska, M., Patterson, A., Berry, L., Scott, L., Balasubramanian, N., & Bothner, B. (2018) · Frontiers in Microbiology · doi:10.3389/fmicb.2018.01397 · Cited by 15 · see citing works
Recent advances of capillary electrophoresis-mass spectrometry instrumentation and methodology
You, Jiang, Mu-Yi, He, H., Wenjing, Zhang, Pan, Luo, L., Dan, D., Guo, et al. (2017) · 中国化学快报:英文版 · Cited by 15 · see citing works
Top-Down Analysis of Branched Proteins Using Mass Spectrometry
Chen, D., Gomes, F., Abeykoon, D., Lemma, B., Wang, Y., Fushman, D., & Fenselau, C. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b05234 · Cited by 14 · see citing works
Self-citationBerardet, C., Kaffy, J., Ongeri, S., & Taverna, M. (2018) · Journal of Chromatography A · doi:10.1016/j.chroma.2018.10.006 · Cited by 11 · see citing works
Yin, Y., Li, G., Guan, Y., & Huang, G. (2016) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.7621 · Cited by 11 · see citing works
Analysis of protamine peptides in insulin pharmaceutical formulations by capillary electrophoresis
Lamalle, C., Servais, A., Demelenne, A., Crommen, J., & Fillet, M. (2016) · Journal of Separation Science · doi:10.1002/jssc.201501093 · Cited by 10 · see citing works
Ali, F., & Cheong, W. J. (2016) · Bulletin of the Korean Chemical Society · doi:10.1002/bkcs.10859 · Cited by 9 · see citing works
Top‐down analysis of novel synthetic branched proteins
Gomes, F., Lemma, B., Abeykoon, D., Chen, D., Wang, Y., Fushman, D., & Fenselau, C. (2019) · Journal of Mass Spectrometry · doi:10.1002/jms.4303 · Cited by 7 · see citing works
Self-citationLarge-scale Top-down Proteomics Using Capillary Zone Electrophoresis Tandem Mass Spectrometry
McCool, E. N., Lubeckyj, R. A., Shen, X., Kou, Q., Liu, X., & Sun, L. (2018) · Journal of Visualized Experiments · doi:10.3791/58644-v · Cited by 6 · see citing works
Stable Isotope Quantitative N-Glycan Analysis by Liquid Separation Techniques and Mass Spectrometry
Mittermayr, S., Albrecht, S., Váradi, C., Millán-Martín, S., & Bones, J. (2017) · Methods in Molecular Biology · doi:10.1007/978-1-4939-6990-6_23 · Cited by 5 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511 · see citing works
Top-down proteomics: challenges, innovations, and applications in basic and clinical research
Brown, K. A., Melby, J. A., Roberts, D. S., & Ge, Y. (2020) · Expert Review of Proteomics · doi:10.1080/14789450.2020.1855982 · Cited by 152 · see citing works
“Capillary zone electrophoresis (CZE) has recently shown great promise as an alternative or complementary front-end separation due to its inherent sensitivity and peak capacity [73].”
BackgroundMethodRoberts, D. S., Loo, J. A., Tsybin, Y. O., Liu, X., Wu, S., Chamot-Rooke, J., Agar, J. N., Paša-Tolić, L., Smith, L. M., & Ge, Y. (2024) · Nature Reviews Methods Primers · doi:10.1038/s43586-024-00318-2 · Cited by 154 · see citing works
Recent advances (2019–2021) of capillary electrophoresis‐mass spectrometry for multilevel proteomics
Chen, D., McCool, E. N., Yang, Z., Shen, X., Lubeckyj, R. A., Xu, T., Wang, Q., & Sun, L. (2021) · Mass Spectrometry Reviews · doi:10.1002/mas.21714 · Cited by 99 · see citing works
McCool, E. N., Xu, T., Chen, W., Beller, N. C., Nolan, S. M., Hummon, A. B., Liu, X.-W., & Sun, L.-L. (2022) · Science Advances · doi:10.1126/sciadv.abq6348 · Cited by 76 · see citing works
MS‐based glycomics and glycoproteomics methods enabling isomeric characterization
Peng, W., Reyes, C. D. G., Gautam, S., Yu, A., Cho, B. G., Goli, M., Donohoo, K. B., Mondello, S., Kobeissy, F. H., & Mechref, Y. S. (2021) · Mass Spectrometry Reviews · doi:10.1002/mas.21713 · Cited by 81 · see citing works
Štěpánová, S., & Kašička, V. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2022.339447 · Cited by 78 · see citing works
Proteomic discovery of non-invasive biomarkers of localized prostate cancer using mass spectrometry
Khoo, A., Liu, L., Nyalwidhe, J. O., Semmes, O. J., Vesprini, D., Downes, M. R., Boutros, P. C., Liu, S. K., & Kislinger, T. (2021) · Nature Reviews Urology · doi:10.1038/s41585-021-00500-1 · Cited by 68 · see citing works
Studying protein structure and function by native separation–mass spectrometry
van Schaick, G., Haselberg, R., Somsen, G. W., Wuhrer, M., & Domínguez‐Vega, E. (2022) · Nature Reviews Chemistry · doi:10.1038/s41570-021-00353-7 · Cited by 66 · see citing works
Papanastasiou, D. K., Kounadis, D., Lekkas, A., Orfanopoulos, I., Mpozatzidis, A., Smyrnakis, A., Panagiotopoulos, E., Kosmopoulou, M., Reinhardt-Szyba, M., Fort, K. L., et al. (2022) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.2c00214 · Cited by 54 · see citing works
Li, X., Ma, Q., Zheng, X., Chen, Q., & Sun, X. (2023) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2023.01.003 · Cited by 56 · see citing works
“Furthermore, carboxyl-modified MNPs deposited by electrostatic self-assembly on positively charged poly-diallyldimethylammonium chloride on the capillary inner surface [79] improved the AAs: amino acids; ABEE: para-aminobenzoic acid ethyl ester; ACOF: azine-linked covalent organic framework; Ad: adenine; ADR: adrenerg…”
BackgroundSchlecht, J., Stolz, A., Hofmann, A., Gerstung, L., & Neusüß, C. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c03213 · Cited by 56 · see citing works
Advances in mass spectrometry‐based glycomics—An update covering the period 2017–2021
Donohoo, K. B., Wang, J., Goli, M., Yu, A., Peng, W., Hakim, M. A., & Mechref, Y. S. (2021) · Electrophoresis · doi:10.1002/elps.202100199 · Cited by 55 · see citing works
Recent developments in capillary and microchip electroseparations of peptides (2019–mid 2021)
Kašička, V. (2021) · Electrophoresis · doi:10.1002/elps.202100243 · Cited by 53 · see citing works
Xu, T., Wang, Q., Wang, Q., & Sun, L. (2024) · Analytical Methods · doi:10.1039/d4ay00651h · Cited by 53 · see citing works
The Hitchhiker's guide to glycoproteomics
Oliveira, T., Thaysen‐Andersen, M., Packer, N. H., & Kolarich, D. (2021) · Biochemical Society Transactions · doi:10.1042/bst20200879 · Cited by 50 · see citing works
Gomes, F. P., Diedrich, J. K., Saviola, A. J., Memili, E., Moura, A. A., & Yates, J. R. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03856 · Cited by 46 · see citing works
Self-citationSalim, H., Pero-Gascon, R., Giménez, E., & Benavente, F. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.1c03800 · Cited by 37 · see citing works
Predicting Electrophoretic Mobility of Proteoforms for Large-Scale Top-Down Proteomics
Chen, D.-Y., Lubeckyj, R. A., Yang, Z.-C., McCool, E. N., Shen, X., Wang, Q.-J., Xu, T., & Sun, L.-L. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05578 · Cited by 32 · see citing works
Huang, L., Fang, M., Cupp‐Sutton, K. A., Wang, Z., Smith, K., & Wu, S. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04624 · Cited by 44 · see citing works
Maráková, K., Opetová, M., & Tomašovský, R. (2023) · Journal of Separation Science · doi:10.1002/jssc.202300244 · Cited by 39 · see citing works
Jooß, K., Schachner, L. F., Watson, R., Gillespie, Z. B., Howard, S. A., Cheek, M. A., Meiners, M. J., Sobh, A., Licht, J. D., Keogh, M., et al. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04975 · Cited by 44 · see citing works
Xu, T., Shen, X., Yang, Z., Chen, D., Lubeckyj, R. A., McCool, E. N., & Sun, L. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c03266 · Cited by 42 · see citing works
Standard procedures for native CZE-MS of proteins and protein complexes up to 800 kDa
Jooss, K., McGee, J., Melani, R., & Kelleher, N. (2020) · bioRxiv · doi:10.1002/elps.202000317 · Cited by 32 · see citing works
Štěpánová, S., & Kašička, V. (2023) · Journal of Separation Science · doi:10.1002/jssc.202300043 · Cited by 40 · see citing works
A Mini Review on Capillary Isoelectric Focusing-Mass Spectrometry for Top-Down Proteomics
Xu, T., & Sun, L.-L. (2021) · Frontiers in Chemistry · doi:10.3389/fchem.2021.651757 · Cited by 30 · see citing works
Native top-down proteomics enables discovery in endocrine resistant breast cancer
Gomes, F. P., Durbin, K. R., Schauer, K. L., Nwachukwu, J., Kobylski, R. R., Njeri, J., Seath, C. P., Saviola, A. J., McClatchy, D. B., Diedrich, J. K., et al. (2025) · Nature Chemical Biology · doi:10.1038/s41589-025-01866-8 · Cited by 34 · see citing works
“Most complexes were identified in the nSEC fractions 4 and 5 (Supplementary Fig.”
InfluentialSelf-citationWu, H., & Tang, K. (2020) · Reviews in Analytical Chemistry · doi:10.1515/revac-2020-0112 · Cited by 34 · see citing works
“Recently, the dramatic improvement in the CE-MS interface and preconcentration techniques has made CE-MS an important analytical tool for large scale topdown and bottom-up proteomics [10-12].”
MethodProteomics and plant biology: contributions to date and a look towards the next decade
Jorrín-Novo, J. V. (2021) · Expert Review of Proteomics · doi:10.1080/14789450.2021.1910028 · Cited by 35 · see citing works
“This is the case, for example, of capillary electrophoresis [103], 3-D electrophoresis [17], multidimensional separa-”
MethodAdvances in mass spectrometry‐based glycoproteomics: An update covering the period 2017–2021
Reyes, C. D. G., Jiang, P., Atashi, M., Bennett, A. I., Yu, A., Peng, W., Zhong, J., & Mechref, Y. S. (2021) · Electrophoresis · doi:10.1002/elps.202100188 · Cited by 33 · see citing works
Choi, S. B., Muñoz-LLancao, P., Manzini, M. C., & Nemes, P. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c03327 · Cited by 31 · see citing works
Multidimensional separations in top–down proteomics
Guo, Y., Cupp‐Sutton, K. A., Zhao, Z., Anjum, S., & Wu, S. (2023) · Analytical Science Advances · doi:10.1002/ansa.202300016 · Cited by 27 · see citing works
“25,52 Apart from LC and CE separation techniques, gel electrophoresis-based techniques have also been applied as a dimension of separation for TDP.”
MethodMass Spectrometry as a Crucial Analytical Basis for Omics Sciences
Zaikin, V. G., & Борисов, Р. С. (2021) · Journal of Analytical Chemistry · doi:10.1134/s1061934821140094 · Cited by 27 · see citing works
Biological mass spectrometry enables spatiotemporal ‘omics: From tissues to cells to organelles
Pade, L. R., Stepler, K. E., Portero, E. P., DeLaney, K., & Nemes, P. (2023) · Mass Spectrometry Reviews · doi:10.1002/mas.21824 · Cited by 28 · see citing works
mAbs N-glycosylation: Implications for biotechnology and analytics
Wang, T., Liu, L., & Voglmeir, J. (2022) · Carbohydrate Research · doi:10.1016/j.carres.2022.108541 · Cited by 26 · see citing works
Ecotoxicological significance of bio-corona formation on micro/nanoplastics in aquatic organisms
Camil Rex, M., Debroy, A., Nirmala, M. J., & Mukherjee, A. (2023) · RSC Advances · doi:10.1039/d3ra04054b · Cited by 25 · see citing works
Wilson, J., Pena, A. B., Wang, J., Liao, Y., Veličković, D., Wojcik, R., Passamonti, M., Zhao, R., Gargano, A., Gerbasi, V. R., et al. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c00139 · Cited by 25 · see citing works
Corradini, D. (2023) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2023.117080 · Cited by 25 · see citing works
An Integrative Synthetic Biology Approach to Interrogating Cellular Ubiquitin and Ufm Signaling
Li, C., Han, T., Guo, R., Chen, P., Peng, C., Prag, G., & Hu, R. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21124231 · Cited by 24 · see citing works
Spray-Capillary: An Electrospray-Assisted Device for Quantitative Ultralow-Volume Sample Handling
Huang, L., Wang, Z., Cupp‐Sutton, K. A., Smith, K., & Wu, S. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04131 · Cited by 23 · see citing works
Wani, H. M. U. D., Chen, C., Huang, C.-Y., Singhania, R. R., Sung, Y. J., Dong, C., & Patel, A. K. (2023) · Sustainability · doi:10.3390/su15118506 · Cited by 23 · see citing works
Hamidli, N., Andrási, M., Nagy, C., & Gáspár, A. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.462448 · Cited by 23 · see citing works
Guzman, N. A., & Guzman, D. E. (2020) · Biomedicines · doi:10.3390/biomedicines8080255 · Cited by 22 · see citing works
Capillary Electrophoresis–Mass Spectrometry for Top-Down Proteomics
Wang, Q., Wang, Q., Zhu, G., & Sun, L. (2025) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071124-092242 · Cited by 22 · see citing works
Dykstra, A. B., Flick, T. G., Lee, B., Blue, L. E., & Angell, N. (2021) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.0c00424 · Cited by 21 · see citing works
Accelerated protein digestion and separation with picoliter volume utilizing nanofluidics
Yamamoto, K., Morikawa, K., Shimizu, H., Sano, H., Kazoe, Y., & Kitamori, T. (2022) · Lab on a Chip · doi:10.1039/d1lc00923k · Cited by 19 · see citing works
Mass Spectrometry-Based Structural Proteomics for Metal Ion/Protein Binding Studies
Lin, Y., & Gross, M. L. (2022) · Biomolecules · doi:10.3390/biom12010135 · Cited by 18 · see citing works
Li, J., Huang, L., Guo, Y., Cupp‐Sutton, K. A., & Wu, S. (2023) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-023-04870-w · Cited by 17 · see citing works
The separation sciences, the front end to proteomics: An historical perspective
Nice, E. C. (2020) · Biomedical Chromatography · doi:10.1002/bmc.4995 · Cited by 17 · see citing works
Unravelling neurological disorders through metallomics-based approaches
de Jesus, J. R., & Arruda, M. A. Z. (2020) · Metallomics · doi:10.1039/d0mt00234h · Cited by 18 · see citing works
Marie, A., Georgescauld, F., Johnson, K. R., Ray, S., Engen, J. R., & Ivanov, A. R. (2024) · Advanced Science · doi:10.1002/advs.202306824 · Cited by 16 · see citing works
Lombard‐Banek, C., & Schiel, J. E. (2020) · Molecules · doi:10.3390/molecules25061396 · Cited by 16 · see citing works
“Capillary electrophoresis, however, continues to emerge as a p werfu compl mentary separation technique in bottom-up proteomic workflows [28,29].”
BackgroundGreenness of proteomic sample preparation and analysis techniques for biopharmaceuticals
Maráková, K., Tomašovský, R., Opetová, M., & Schug, K. A. (2023) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2023.117490 · Cited by 15 · see citing works
Bo, T., Yang, F., Yan, B., Michels, D., Huang, T.-M., & Pawliszyn, J. (2025) · Trends in Analytical Chemistry (TrAC) · doi:10.1016/j.trac.2025.118212 · Cited by 15 · see citing works
Salim, H., Pont, L., Giménez, E., & Benavente, F. (2023) · Analytica Chimica Acta · doi:10.1016/j.aca.2023.341149 · Cited by 15 · see citing works
Opetová, M., Tomašovský, R., Mikuš, P., & Maráková, K. (2024) · Journal of Chromatography A · doi:10.1016/j.chroma.2024.464697 · Cited by 14 · see citing works
Piešťanský, J., Čižmárová, I., Štefánik, O., Matušková, M., Horniaková, A., Majerová, P., & Mikuš, P. (2021) · Biomedicines · doi:10.3390/biomedicines9101488 · Cited by 14 · see citing works
Probing protein higher-order structures by native capillary electrophoresis-mass spectrometry
Zhang, W., Xiang, Y., & Xu, W. L. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116739 · Cited by 14 · see citing works
Wang, Q., Gao, G., Fang, F., Wang, Q., Lundquist, P. K., & Sun, L. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.343162 · Cited by 13 · see citing works
Štěpánová, S., & Kašička, V. (2025) · Analytica Chimica Acta · doi:10.1016/j.aca.2025.344323 · Cited by 13 · see citing works
Reider, B., Járvás, G., Křenková, J., & Guttman, A. (2020) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2020.113797 · Cited by 12 · see citing works
Nagy, C., Andrási, M., Hamidli, N., Gyémánt, G., & Gáspár, A. (2021) · Journal of Chromatography Open · doi:10.1016/j.jcoa.2021.100024 · Cited by 12 · see citing works
Sarpong‐Kumankomah, S., Knox, K. B., Kelly, M., Hunter, G. R. W., Popescu, B. F. G., Nichol, H. K., Kopciuk, K. A., Ntanda, H. N., & Gailer, J. (2022) · PLoS ONE · doi:10.1371/journal.pone.0262160 · Cited by 11 · see citing works
“5 mL) for ~12 metalloentities [16, 18, 19] and is complementary to the determination of plasma protein biomarkers with more conventional analytical methods, such as mass spectrometry-based proteomics and/or radioimmunoassaybased methods [6, 20].”
MethodDifferences in Blood and Cerebrospinal Fluid Between Parkinson’s Disease and Related Diseases
Ma, J., Tang, Z., Wu, Y., Zhang, J., Wu, Z., Huang, L., Liu, S., & Wang, Y. (2024) · Cellular and Molecular Neurobiology · doi:10.1007/s10571-024-01523-z · Cited by 10 · see citing works
“CE-MS proved to be an excellent platform for peptide analysis because of its multi-dimen-sionality, rapidity, and high sensitivity (Gomes et al. 2019; Pero-Gascon et al. 2020).”
Pathak, K., Perrotti, G., Rosa, S. J., Robinett, G., Kasper, L., Xia, Q., Escalante, C. R., & Gomes, F. P. (2025) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.5c00074 · Cited by 11 · see citing works
Self-citationReinert, T., Gahoual, R., Mignet, N., Kulus, A., Allez, M., Houzé, P., & François, Y. (2023) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2023.115446 · Cited by 10 · see citing works
Gels in Microscale Electrophoresis
Holland, L., & Casto-Boggess, L. D. (2023) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-091522-080207 · Cited by 10 · see citing works
Höchsmann, A., Frick, H., Dhellemmes, L., Leclercq, L., Kaulich, P. T., Tholey, A., Cottet, H., Schaschke, N., & Neusüß, C. (2025) · PROTEOMICS · doi:10.1002/pmic.70012 · Cited by 8 · see citing works
Stolaki, E. V., Psatha, K., & Aivaliotis, M. (2025) · Metabolites · doi:10.3390/metabo15110750 · Cited by 9 · see citing works
“Additionally, injection volumes in CE are in the nanoliter range, meaning that only microliter-level volumes of biosamples are required [51,77,78].”
Capillary electrophoresis - A bibliometric analysis
Palmblad, M., van Eck, N. J., & Bergquist, J. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116899 · Cited by 9 · see citing works
Pomilio, A. B., Vitale, A. A., & Lazarowski, A. (2022) · Current Pharmaceutical Design · doi:10.2174/1381612828666220413094918 · Cited by 8 · see citing works
Yu, H.-Y., Tai, Q., Yang, C.-J., Gao, M.-X., & Zhang, X.-M. (2023) · Journal of Chromatography A · doi:10.1016/j.chroma.2023.464048 · Cited by 7 · see citing works
Sample preparation of blood plasma enables baseline separation of iron metalloproteins by SEC-GFAAS
Miller, K., Sarpong‐Kumankomah, S., Egorov, A., & Gailer, J. (2020) · Journal of Chromatography B · doi:10.1016/j.jchromb.2020.122147 · Cited by 8 · see citing works
Analysis of lysozyme in human saliva by CE-UV: A new simple, fast, and reliable method
Tomašovský, R., Opetová, M., Polačková, M., & Maráková, K. (2025) · Talanta · doi:10.1016/j.talanta.2025.128605 · Cited by 7 · see citing works
Ouahabi, O. E., Mancera-Arteu, M., Pont, L., Giménez, E., Sanz‐Nebot, V., & Benavente, F. (2022) · Microchemical Journal · doi:10.1016/j.microc.2022.108089 · Cited by 7 · see citing works
Beloborodov, S. S., Schneider, B. B., Oleschuk, R. D., & Blanc, J. C. Y. L. (2023) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.3c00060 · Cited by 6 · see citing works
Xiang, H., Song, W., Hao, S., & Sun‐Waterhouse, D. (2026) · Journal of Future Foods · doi:10.1016/j.jfutfo.2025.12.020 · Cited by 5 · see citing works
Roca, S., Leclercq, L., & Cottet, H. (2024) · Journal of Chromatography A · doi:10.1016/j.chroma.2024.464719 · Cited by 5 · see citing works
Research of saccharides and related biocomplexes: A review with recent techniques and applications
Sirén, H. M. M. (2024) · Journal of Separation Science · doi:10.1002/jssc.202300668 · Cited by 5 · see citing works
CE–MS Approaches for Peptidomics
Štěpánová, S., & Kašička, V. (2022) · Wiley eBooks · doi:10.1002/9783527833092.ch9 · Cited by 4 · see citing works
Zhu, G., Rodriguez, D. A. A., Gould, N., Ivanov, A. R., Jooß, K., & Sun, L. (2026) · Mass Spectrometry Reviews · doi:10.1002/mas.70028 · Cited by 3 · see citing works
Recent Advances in Top‐Down Proteomics for Single‐Cell Research
Melby, J. A., Su, P., & Gomes, F. P. (2026) · Mass Spectrometry Reviews · doi:10.1002/mas.70031 · Cited by 3 · see citing works
Self-citationAm, A., Faccio, M. E., Pinvidic, M., Reygue, E., Doan, B., Lescot, C., Trapiella‐Alfonso, L., d’Orlyé, F., & Varenne, A. (2023) · Journal of Chromatography A · doi:10.1016/j.chroma.2023.464496 · Cited by 3 · see citing works
McElroy, W., Huang, S., He, X. Z., Zhou, C. J., Heger, C. D., Powers, T. W., Anderson, M. M., Sloan, C. D. K., & Lerch, T. F. (2025) · Electrophoresis · doi:10.1002/elps.202400201 · Cited by 3 · see citing works
“Acetic acid is a commonly used mobilizer and is MS-compatible [24] with added benefit of producing a lower current than NH 4 OAc at the same concentrations.”
Angiotensin detection: A comprehensive review of current methods and novel technologies
Deng, F., Wang, R., Wu, L., Yang, G., Su, R. J., & Liu, Y. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.111592 · Cited by 3 · see citing works
Zhu, G., Yue, Y., Colón-Rosado, J. A., Gao, G., Liu, X., & Sun, L. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.01.28.702308 · Cited by 3 · see citing works
Pathak, K., Brinkman, D., & Gomes, F. P. (2026) · Journal of Mass Spectrometry · doi:10.1002/jms.70075 · Cited by 2 · see citing works
Self-citationHu, X., Gao, W., Liu, R., Tang, C. Y., Wu, H., Yu, J., Wang, Y., & Tang, K. (2024) · Talanta · doi:10.1016/j.talanta.2024.127045 · Cited by 2 · see citing works
Magnetoresistive (MR) biosensor
Liang, S. A., Wu, K., & Wang, J. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-21668-8.00010-9 · Cited by 2 · see citing works
Biological Chemistry of Toxic Metals and Metalloids, Such as Arsenic, Cadmium, and Mercury
Sarpong‐Kumankomah, S., Miller, K., & Gailer, J. (2020) · Encyclopedia of Analytical Chemistry · doi:10.1002/9780470027318.a9681 · Cited by 2 · see citing works
McCool, E. N., Xu, T., Chen, W., Beller, N. C., Nolan, S. M., Hummon, A. B., Liu, X., & Sun, L.-L. (2021) · bioRxiv · doi:10.1101/2021.10.27.466093
“[27,28] The list of identified proteoforms is shown in Supporting Information II.”
BackgroundCE–MS Methods for the Characterization of Monoclonal Antibodies
Reinert, T., Beck, A., Houzé, P., Gahoual, R., & François, Y. (2022) · Wiley eBooks · doi:10.1002/9783527833092.ch11 · Cited by 2 · see citing works
Wen, X., Bou, G., He, Q., Liu, Q., Yi, M., & Ren, H. (2025) · Proteomes · doi:10.3390/proteomes13030033 · Cited by 1 · see citing works
“Proteomics refers to the identification and quantification of proteins in biological samples through advanced technological approaches, thereby offering a comprehensive perspective on protein abundance [17,18].”
Silva, M. D., & Dunn, R. C. (2025) · Electrophoresis · doi:10.1002/elps.70031 · Cited by 1 · see citing works
Cancer Genes: Origins and Directions
Vogt, P. K. (2026) · Viruses · doi:10.3390/v18070702 · Cited by 1 · see citing works
Detection Methods and Regulatory Workflows for Common Unauthorized Substances in Chili Products
Yang, X., Yi, B., & Xu, H. (2026) · Applied Sciences · doi:10.3390/app16157492 · Cited by 1 · see citing works
Capillary Electrophoresis: Basic Principles
Kalaycıoğlu, Z., & Erim, F. B. (2022) · Current and future developments in food science · doi:10.2174/9789815036152122020004 · Cited by 1 · see citing works
Kütle Spektrometresinden Glikan Mikrodizilerine: Glikomikte Analitik Tekniklere Genel Bir Bakış
Tekin, B., & Gurbanov, R. (2024) · Bilecik Şeyh Edebali Üniversitesi Fen Bilimleri Dergisi · doi:10.35193/bseufbd.1322614 · Cited by 1 · see citing works
Capillary electrophoresis of glycoproteins
Puerta, A., Gomez-Ruiz, L., Díez‐Masa, J. C., & de Frutos, M. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-821447-3.00009-3 · Cited by 1 · see citing works
- Authors
- Gomes, F. P., & Yates, J. R.
- Affiliations
- The Scripps Research Institute La Jolla CA 92037
- Scripps Research Institute (US)
- Corresponding author
- Yates, John R.
- ORCID
- Yates, John R.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2019-08-12
- Volume
- 38
- Issue
- 6
- Pages
- 445-460
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- PMC
- PMC6800771
- OpenAlex
- W2968805832
- Cited by
- 112
- References
- 141
- Citations by year
- 2026: 8 · 2025: 15 · 2024: 13 · 2023: 17 · 2022: 20 · 2021: 23 · 2020: 15 · 2019: 1
- FWCI
- 1.53
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Mass Spectrometry Reviews (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health
- National Institute of General Medical Sciences (P41GM103533)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- capillary electrophoresis-mass spectrometry, proteomics, top-down mass spectrometry, native mass spectrometry, protein identification, protein quantification, post-translational modification, protein complexes, peptide analysis, biological specimen
- MeSH terms
- Animals, Humans, Mass Spectrometry, Electrophoresis, Capillary, Proteome, Spectrometry, Mass, Electrospray Ionization, Proteomics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-05.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-05.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review