CoChat

Deformation of oriented polyethylene

Pope, D. P., Keller, A. · 1975 · Journal of Polymer Science: Polymer Physics Edition
Cited by 113

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The deformation of polyethylene in terms of structural processes has been investigated by low‐and wide‐angle x‐ray diffraction in the case of low‐density and, to a lesser extent, high‐density polyethylene. The samples possessed a range of simple textures which enabled the deformation processes to be identified. The results are interpreted in terms of a model of stacks of lamellae which have axes along the original draw direction and which deform by lamellar slip, chain slip, and lamellar separation. In most cases these processes accounted for the macroscopic strain but in some cases discrepancies were observed which could be accounted for by inhomogeneous deformation or by the effects of a distribution of lamellar thicknesses. Attempts were made to identify fibrillar slip, without success. The relative contributions of the various deformation processes are examined as a function of temperature and sample treatment by defining a compliance constant for each process. Below room temperature, the results are consistent with expectations based on the α and β mechanical relaxations, whereas the unusual effects at high temperatures are attributed to gradual melting. The compliance constants are also found to depend on the annealing temperature of the sample, and are used to predict the mechanical anisotropy. The volume changes accompanying lamellar separation are examined. They were less than expected in low‐density polyethylene, but satisfactory agreement was obtained in high‐density polyethylene. A general relation is suggested between volume changes and the lateral development of the lamellae. Hence in narrow lamellae the interlamellar layer can contract laterally whereas the greater constraints imposed by wide lamellae lead to void formation. Other effects examined include the reversibility of the processes which is most marked in the case of chain slip and which is explained by the presence of restoring forces in the amorphous regions including the fold surface. Finally, the differences between low‐ and highdensity polyethylene are highlighted, emphasizing the part played in the deformation by the amorphous component.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/pol.1975.180130307

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 113

Metadata

Authors
Pope, D. P., & Keller, A.
Venue
Journal of Polymer Science: Polymer Physics Edition
Publisher
Wiley
Published
1975-03
Volume
13
Issue
3
Pages
533-566
ISSN
  • 0098-1273 (ISSN-L)
  • 1542-9385
OpenAlex
W2144174921
Cited by
113
References
1
FWCI
6.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.