Cited by 89Thermal properties of materialsPolymer Foaming and CompositesPolymer crystallization and properties

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Applicability of the transient plane source method to measure the thermal conductivity of low‐density polyethylene foams

Almanza, O., Rodríguez‐Pérez, M. A., De Saja, J. A.·2004·Journal of Polymer Science Part B: Polymer Physics

Abstract

The thermal conductivity at constant pressure of a collection of crosslinked, closed‐cell polyethylene foams were measured at room temperature with the transient plane source (TPS) method. The experimental results were compared with those determined by a standard steady‐state technique. The results showed that the values measured by the TPS method follow the same trends as those measured by a heat‐flow meter. Therefore, with the TPS technique it is possible to observe the influence of structural characteristics such as cell size, black carbon content in foams, density, and so forth on thermal conductivity. However, the values obtained by the transient method were approximately 20% higher than those given by the standard method. Possible reasons for these variations are discussed. © 2004 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys 42: 1226–1234, 2004

Overview

Integrity signals

Registry

Crossref · 10.1002/polb.20005

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Show all 1 references

Research works printed but not linked: 14

  1. 10.1002/(SICI)1099-0488(20000401)38:7<993::AID-POLB10>3.0.CO;2-J · DOI
  2. 10.1081/MB-100106180 · DOI
  3. Almanza O., 1999, Cell Polym, 18, 385
  4. 10.1016/S0735-1933(01)00310-4 · DOI · Paper page
  5. Tye R. P.Proceedings of the Cellular Polymers an International Conference London March1991; Rapra Technology Ltd.
  6. Tye R. P., 1981, High Temperature High Pressures, 13, 695
  7. 10.1063/1.1145178 · DOI · Paper page
  8. 10.1002/fam.810190107 · DOI
  9. 10.1016/S0266-3538(00)00162-7 · DOI
  10. 10.1016/S0014-3057(98)00247-X · DOI
  11. Carslaw H. S., 1959, Conduction of Heat in Solid
  12. Hust J. G., 1985, Round Robin on the Apparent Thermal Conductivity of low Density Glass Fiber Insulation Using Guarded Hot Plate and Heat Flow Meter apparatus
  13. 10.1520/STP18502S · DOI
  14. Hust J. G., 1989, Interlaboratory Comparison of Two Types of Line Source Apparatus Measuring Thermal Insulating Materials

Cited by

Sorted by citations

See all 89

Metadata

Authors
Almanza, O., Rodríguez‐Pérez, M. A., & De Saja, J. A.
Affiliations
  • Universidad Nacional de Colombia (CO)
  • Universidad de Valladolid (ES)
Venue
Journal of Polymer Science Part B: Polymer Physics
Publisher
Wiley
Published
2004-02-11
Volume
42
Issue
7
Pages
1226-1234
ISSN
  • 0887-6266 (ISSN-L)
  • 1099-0488
OpenAlex
W2153781005
Cited by
89
References
1
Citations by year
2026: 1 · 2025: 3 · 2024: 4 · 2023: 7 · 2022: 9 · 2021: 6 · 2020: 6 · 2019: 6 · 2018: 9 · 2017: 6 · 2016: 3 · 2015: 2 · 2014: 3 · 2013: 1 · 2012: 6
FWCI
0.83
Type
journal article
Language
en
Open access
closed
Locations
Journal of Polymer Science Part B Polymer Physics (publishedVersion)
Funders
Junta de Castilla y Leon (VA026/03)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Thermal properties of materials
  • Physical Sciences › Materials Science › Polymers and Plastics › Polymer Foaming and Composites
  • Physical Sciences › Materials Science › Polymers and Plastics › Polymer crystallization and properties
Keywords
transient plane source method, thermal conductivity, low-density polyethylene foam, closed-cell foam, cross-linked polyethylene, heat flow meter, cell size, foam density, measurement method comparison

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review