The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Rheological properties and crystallization behavior of multi‐walled carbon nanotube/poly(ε‐caprolactone) composites
Abstract
Multi‐walled carbon nanotube/poly(ε‐caprolactone) composites (PCLCNs) were prepared by melt compounding. The rheology, nonisothermal crystallization behavior, and thermal stability of PCLCNs were, respectively, investigated by the parallel‐plate rheometer, differential scanning calorimeter, and TGA. Cole–Cole plots were employed successfully to detect the rheological percolation of PCLCNs under small amplitude oscillatory shear. PCLCNs present a low percolation threshold of about 2–3 wt % in contrast to that of clay‐based nanocomposites. The percolated nanotube network is very sensitive to the steady shear deformation, and is also to the temperature, which makes the principle of time‐temperature superposition be invalid on those percolated PCLCNs. Small addition of nanotube cannot improve the thermal stability of PCL but can increase crystallization temperature remarkably due to the nucleating effect. As the nanotube is much enough to be percolated, however, the impeding effect becomes the dominant role on the crystallization, and the thermal stability increases to some extent. © 2007 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys 45: 3137–3147, 2007
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics
Cole, K. S., & Cole, R. H. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750906 · Cited by 10,152
Mechanisms and Kinetics of Thermal Degradation of Poly(ε-caprolactone)
Persenaire, O., Alexandre, M., Degée, P., & Dubois, P. (2001) · Biomacromolecules · doi:10.1021/bm0056310 · Cited by 444
Cited by
Chrissafis, K., & Bikiaris, D. (2011) · Thermochimica Acta · doi:10.1016/j.tca.2011.06.010 · Cited by 561
Selective Localization of Multiwalled Carbon Nanotubes in Poly(ε-caprolactone)/Polylactide Blend
Wu, D., Zhang, Y., Zhang, M., & Yu, W. (2009) · Biomacromolecules · doi:10.1021/bm801183f · Cited by 372
Self-citationGoh, P. S., Ismail, A. F., & Ng, B. C. (2014) · Composites Part A: Applied Science and Manufacturing · doi:10.1016/j.compositesa.2013.10.001 · Cited by 260
Lahiri, D., Rouzaud, F., Richard, T., Keshri, A. K., Bakshi, S. R., Kos, L., & Agarwal, A. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.02.044 · Cited by 256
Wu, D., Wu, L., Zhang, M., & Zhao, Y. (2008) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2008.05.001 · Cited by 256
Self-citation
Metadata
- Authors
- Wu, D., Wu, L., Sun, Y., & Zhang, M.
- Venue
- Journal of Polymer Science Part B: Polymer Physics
- Publisher
- Wiley
- Published
- 2007-10-22
- Volume
- 45
- Issue
- 23
- Pages
- 3137-3147
- ISSN
- 0887-6266 (ISSN-L)
- 1099-0488
- OpenAlex
- W2020143007
- Cited by
- 169
- References
- 2
- FWCI
- 6.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.