The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Comparison of Direct and Indirect Effects of Non‐Thermal Atmospheric‐Pressure Plasma on Bacteria
Abstract
Direct and indirect influence on microorganisms of non‐thermal atmospheric‐pressure DBD in air is compared in terms of bacterial inactivation rates. It is demonstrated that direct influence of the plasma, where charged particles contact bacteria directly, produces inactivation much faster than the indirect treatment, where plasma afterglow is delivered to the bacteria with a gas flow through the plasma region. This leads to an important conclusion that the effect of charged particles on plasma plays the essential role in interaction with living organisms, although synergy with longer living active molecules and atoms as well as UV radiation generated in plasma and at the surface of tissues may also play a role in inactivation. magnified image
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical diagnosis and management by laboratory methods
Henry, J. B. (1979) · Medical Entomology and Zoology · Cited by 1,691
Plasma-surface modification of biomaterials
Chu, P. (2002) · Materials Science and Engineering: R: Reports · doi:10.1016/s0927-796x(02)00004-9 · Cited by 1,578
Laroussi, M., & Leipold, F. (2004) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2003.11.016 · Cited by 866
Human Physiology: An Integrated Approach
Silverthorn, D. U. (1997) · Cited by 628
Stoffels, E., Flikweert, A. J., Stoffels, W. W., & Kroesen, G. M. W. (2002) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/11/4/304 · Cited by 616
Gaunt, L. F., Beggs, C. B., & Georghiou, G. E. (2006) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2006.878381 · Cited by 342
Inactivation of cryptosporidium parvum oocysts using medium- and low-pressure ultraviolet radiation
Craik, S. A., Weldon, D., Finch, G. R., Bolton, J. R., & Belosevic, M. (2001) · Water Research · doi:10.1016/s0043-1354(00)00399-7 · Cited by 233
Reattachment and Apoptosis After Plasma-Needle Treatment of Cultured Cells
Kieft, I. E., Kurdi, M., & Stoffels, E. (2006) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2006.876511 · Cited by 162
Argon plasma coagulation for open surgical and endoscopic applications: state of the art
Raiser, J., & Zenker, M. (2006) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/39/16/s10 · Cited by 153
Biofilm Destruction by RF High-Pressure Cold Plasma Jet
Abramzon, N., Joaquin, J. C., Bray, J., & Brelles-Mariño, G. (2006) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2006.877515 · Cited by 135
Herbold, K., Flehmig, B., & Botzenhart, K. (1989) · Applied and Environmental Microbiology · doi:10.1128/aem.55.11.2949-2953.1989 · Cited by 102
Finite element analysis of an atmospheric pressure RF-excited plasma needle
Sakiyama, Y., & Graves, D. B. (2006) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/39/16/s01 · Cited by 84
The influence of substrate material on bacteria sterilization in an oxygen plasma glow discharge
Cvelbar, U., Vujošević, D., Vratnica, Z., & Mozetič, M. (2006) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/39/16/s06 · Cited by 67
Scanning Electron and Atomic Force Microscopy to Study Plasma Torch Effects on B. cereus Spores
Tarasenko, O., Nourbakhsh, S., Kuo, S. P., Bakhtina, A., Alusta, P., Kudasheva, D., Cowman, M., & Levón, K. (2006) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2006.878378 · Cited by 27
Killing of Bacterial Spores Contained in a Paper Envelope by a Microwave Plasma Torch
Kuo, S. P., Tarasenko, O., Popović, S., & Levón, K. (2006) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2006.878389 · Cited by 27
Cited by
Fridman, G., Friedman, G., Gutsol, A., Shekhter, A. B., Vasilets, V. N., & Fridman, A. (2008) · Plasma Processes and Polymers · doi:10.1002/ppap.200700154 · Cited by 2,084
Self-citationPlasma medicine: an introductory review
Kong, M. G., Kroesen, G., Morfill, G., Nosenko, T., Shimizu, T., van Dijk, J., & Zimmermann, J. L. (2009) · New Journal of Physics · doi:10.1088/1367-2630/11/11/115012 · Cited by 1,601
Lu, X., Naidis, G. V., Laroussi, M., Reuter, S., Graves, D. B., & Ostrikov, K. (2016) · Physics Reports · doi:10.1016/j.physrep.2016.03.003 · Cited by 1,230
von Woedtke, T., Reuter, S., Masur, K., & Weltmann, K.-D. (2013) · Physics Reports · doi:10.1016/j.physrep.2013.05.005 · Cited by 848
On atmospheric-pressure non-equilibrium plasma jets and plasma bullets
Lu, X., Laroussi, M., & Puech, V (2012) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/21/3/034005 · Cited by 844
Metadata
- Authors
- Fridman, G., Brooks, A. D., Balasubramanian, M., Fridman, A., Gutsol, A., Vasilets, V. N., Ayan, H., & Friedman, G.
- Venue
- Plasma Processes and Polymers
- Publisher
- Wiley
- Published
- 2007-05-22
- Volume
- 4
- Issue
- 4
- Pages
- 370-375
- ISSN
- 1612-8850 (ISSN-L)
- 1612-8869
- OpenAlex
- W2124619605
- Cited by
- 546
- References
- 15
- FWCI
- 18.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.