CoChat

Cytokine levels in sputum of cystic fibrosis patients before and after antibiotic therapy

Colombo, Carla, Costantini, Diana, Rocchi, Alessia, Cariani, Lisa, Garlaschi, Maria Laura, Tirelli, Silvia, Calori, Giliola, Copreni, Elena, Conese, Massimo · 2005 · Pediatric Pulmonology
Cited by 94

The DOI matches its Crossref record.

Abstract

It is not known whether cytokine levels in sputum may be used as outocome measures after parenteral antibiotic therapy in cystic fibrosis (CF) patients. Here, we assessed the effects of antibiotic therapy on cytokine levels in sputum and serum obtained from young CF patients. Thirty‐two CF patients (14 females; mean age, 18.6 years; range, 11.4–35.7 years), consecutively admitted at the CF Center of Milan for parenteral antibiotic therapy during pulmonary exacerbation, were enrolled in the study. Before and after 21 days (range, 5–41) of intravenous antibiotic treatment, all patients underwent routine laboratory determinations (including white blood cell (WBC) count and C‐reactive protein (CRP)), a chest X‐ray, pulmonary function tests (forced expiratory volume in 1 sec (FEV 1) and forced vital capacity (FVC) as % predicted), and sputum cultures. Interleukin (IL)‐6, IL‐8, IL‐10, and tumor necrosis factor (TNF)‐α levels in serum and sputum samples were determined by means of immunometric assays. After therapy, FEV 1 and FVC significantly improved (median increase of 7.5% and 8.5% predicted, respectively), while CRP and WBC count were signifcantly decreased (median values from 14 to 5.5 mg/dl and from 8,350 to 7,400 n/mm 3, respectively). While levels of IL‐6 and IL‐10 in sputum were generally undetectable, IL‐8 and TNF‐α were always measurable, and IL‐8 levels significantly decreased after antibiotic treatment (median values from 7,165 to 5,415 pg/ml). Following antibiotic therapy, IL‐8 and TNF‐α levels in sputum were inversely related with both FEV 1 and FVC. In conclusion, TNF‐α and IL‐8 levels in sputum of young CF patients with pulmonary exacerbation were always detectable and may be useful, noninvasive outcome measures to assess response to therapy in CF patients. © 2005 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ppul.20237

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Colombo, C., Costantini, D., Rocchi, A., Cariani, L., Garlaschi, M. L., Tirelli, S., Calori, G., Copreni, E., & Conese, M.
Venue
Pediatric Pulmonology
Publisher
Wiley
Published
2005-04-27
Volume
40
Issue
1
Pages
15-21
ISSN
  • 1099-0496 (ISSN-L)
  • 8755-6863
OpenAlex
W2001587323
Cited by
94
References
0
FWCI
6.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.