Endogeneous peptide profiling of cerebrospinal fluid by MALDI‐TOF mass spectrometry: Optimization of magnetic bead‐based peptide capture and analysis of preanalytical variables
The DOI matches its Crossref record.
Abstract
Cerebrospinal fluid (CSF) perfuses the brain and spinal cord. CSF contains peptides and proteins important for brain physiology and potentially also relevant to brain pathology. High‐throughput endogeneous peptide profiling by MS is an emerging approach for disease diagnosis and biomarker discovery. A magnetic bead‐based method for off‐line serum peptide capture coupled to MALDI‐TOF‐MS has been introduced recently. In this study, we optimize the peptide capture method for profiling of CSF and investigate the effect of a number of preanalytical variables. The CSF profiles contain ∼100 reliably detected peptides at m/z 800–4000 with reproducible ion intensities (average 7% CV). The investigated preanalytical variables include: time at room temperature (RT) before storage, storage temperature, freeze‐thawing cycles, and blood contamination. The CSF peptidome (<20 kDa) is relatively stable and can withstand a few hours at RT and several freeze‐thaw cycles. Several peptides sensitive to storage at −20°C, including Cystatin C, were assigned based on mass or identified by MS/MS. Hemoglobin α and β chains were detected in blood contaminated samples, at levels invisible to the eye (0.01%). These peptides may be used for quality control in a MALDI‐TOF‐MS screening strategy to select high quality samples for in‐depth proteomics analysis in disease studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A consensus protocol for the standardization of cerebrospinal fluid collection and biobanking
Teunissen, C. E., Petzold, A., Bennett, J. L., Berven, F. S., Brundin, L., Comabella, M., Franciotta, D., Frederiksen, J. L., Fleming, J. O., Furlan, R., et al. (2009) · Neurology · doi:10.1212/wnl.0b013e3181c47cc2 · Cited by 845
Self-citationVanderstichele, H., Bibl, M., Engelborghs, S., Le Bastard, N., Lewczuk, P., Molinuevo, J. L., Parnetti, L., Perret‐Liaudet, A., Shaw, L. M., Teunissen, C., et al. (2012) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2011.07.004 · Cited by 358
“However, using an atraumatic needle for LP [41], centrifugation before the initial freezing (Key Issue 5) has been shown to reduce the interfering effect of blood cells by removing them from the CSF sample [58,59].”
MethodSelf-citationdel Campo, M., Mollenhauer, B., Bertolotto, A., Engelborghs, S., Hampel, H., Simonsen, A. H., Kapaki, E., Kruse, N., Le Bastard, N., Lehmann, S., et al. (2012) · Biomarkers in Medicine · doi:10.2217/bmm.12.46 · Cited by 343
Self-citationLewczuk, P., Riederer, P., O’Bryant, S. E., Verbeek, M. M., Dubois, B., Visser, P. J., Jellinger, K. A., Engelborghs, S., Ramirez, A., Parnetti, L., et al. (2018) · The World Journal of Biological Psychiatry · doi:10.1080/15622975.2017.1375556 · Cited by 307
Self-citationTeunissen, C. E., Petzold, A., Bennett, J. L., Berven, F. S., Brundin, L., Comabella, M., Franciotta, D., Federiksen, J. L., Fleming, J. O., Furlan, R., et al. (2010) · LaboratoriumsMedizin · doi:10.1515/jlm.2010.001 · Cited by 162
Self-citation
Metadata
- Authors
- Jimenez, C. R., Koel‐Simmelink, M., Pham, T. V., van der Voort, L., & Teunissen, C. E.
- Venue
- PROTEOMICS – Clinical Applications
- Publisher
- Wiley
- Published
- 2007-11
- Volume
- 1
- Issue
- 11
- Pages
- 1385-1392
- ISSN
- 1862-8346 (ISSN-L)
- 1862-8354
- OpenAlex
- W1982172738
- Cited by
- 37
- References
- 0
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Endogeneous peptide profiling of cerebrospinal fluid by MALDI‐TOF mass spectrometry: Optimization of magnetic bead‐based peptide capture and analysis of preanalytical variables. https://app.cochat.ai/papers/10.1002/prca.200700330
- The paper
- Jimenez, C. R., Koel‐Simmelink, M., Pham, T. V., van der Voort, L., & Teunissen, C. E. (2007). Endogeneous peptide profiling of cerebrospinal fluid by MALDI‐TOF mass spectrometry: Optimization of magnetic bead‐based peptide capture and analysis of preanalytical variables. PROTEOMICS – Clinical Applications. https://doi.org/10.1002/prca.200700330
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.