The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Reliability of goniometric measurements and visual estimates of hip ROM in patients with osteoarthrosis
Abstract
Background and Purpose: Range of motion (ROM) measurements have been included in several hip scores evaluating the results after hip surgery. The clinical procedures of performing these measurements vary and disagreement exists about the accuracy of visual estimatess compared to goniometer measurements. The purpose of this study was to study the reliability of goniometric measurements and visual estimates of hip ROM in patients with osteoarthrosis. Method: Hip ROM measurements (abduction, adduction, extension, flexion and internal/external rotation) were recorded by four different teams on the same day and were repeated one week later. Teams 1, 2 and 3 consisted of physiotherapists using standardized goniometric measurements. Team 4 involved an experienced orthopaedic surgeon making the assessments from visual estimates only. Twenty‐five patients (6 M, 19 F; mean age 68.5 years, range 46–76 years) with osteoarthrosis of the hip, verified both clinically and radiologically, participated in the study. Results: With the exception of abduction (p=0.03), there were no significant differences between the measurements recorded on the first and the second occasions for the same teams. The coefficient of variance was 5.5% for flexion (lowest) and 26.1% for extension (highest). Reproducibility was best for flexion. There was also high reliability when all the arcs of motion were summed up (abuction + adduction + extension + flexion + internal/external rotation). With the exception of internal rotation, there were highly significant differences between the teams when two people performed the measurements compared to the values measured by a single individual. Concordance, expressed as the standardized agreement index, between visual estimates made by one individual (the orthopaedic surgeon) and goniometric measurements made by two experienced physiotherapists, were 0.77–0.83 which indicates good agreement. Conclusion: The reproducibility of hip ROM measurements was highest for flexion. There was also high reliability when all the six arcs of motion were summed up. Concordance between visual estimates and goniometric measurements indicates good agreement. Copyright © 2000 Whurr Publishers Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Cited by
Mean 20-year Followup of Bernese Periacetabular Osteotomy
Steppacher, S. D., Tannast, M., Ganz, R., & Siebenrock, K. A. (2008) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-008-0242-3 · Cited by 611
Relationship Between Offset Angle Alpha and Hip Chondral Injury in Femoroacetabular Impingement
Johnston, T. L., Schenker, M. L., Briggs, K. K., & Philippon, M. J. (2008) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2008.01.010 · Cited by 292
Nussbaumer, S., Leunig, M., Glatthorn, J. F., Stauffacher, S., Gerber, H., & Maffiuletti, N. A. (2010) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-11-194 · Cited by 262
Schiefer, C., Kraus, T., Ellegast, R. P., & Ochsmann, E. (2015) · Journal of Occupational Medicine and Toxicology · doi:10.1186/s12995-015-0058-5 · Cited by 31
Metadata
- Authors
- Holm, I., Bolstad, B., Lütken, T., Ervik, A., Røkkum, M., & Steen, H.
- Venue
- Physiotherapy Research International
- Publisher
- Wiley
- Published
- 2000-11
- Volume
- 5
- Issue
- 4
- Pages
- 241-248
- ISSN
- 1358-2267 (ISSN-L)
- 1471-2865
- OpenAlex
- W2097195008
- Cited by
- 164
- References
- 2
- FWCI
- 1.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.