A technical support tool for joint range of motion determination in functional diagnostics—An inter-rater study
Open accessAbstract
BACKGROUND: The examination of joint range of motion (RoM) is part of musculo-skeletal functional diagnostics, used, for example, in occupational examinations. Various examination methodologies exist that have been optimized for occupational medical practice, which means they were reduced to the most necessary and feasible measures and examinations for efficiency and usability reasons. Because of time constraints in medical examinations in occupational settings, visual inspection is commonly used to quantify joint RoM. To support medical examiners, an inertial sensor-based measurement system (CUELA) was adapted for joint RoM examination in these settings. The objective of the present study was to evaluate the measurement tool in functional diagnostics under conditions close to clinical practice. METHODS: The joint RoM of twenty healthy subjects were examined by three physicians, who were simultaneously using the measurement tool. Physicians were blinded to the measurement results and the other physicians. Active RoM was examined on the cervical, thoracic and lumbar spine while passive RoM was examined on the shoulder, elbow, wrist, hip, and knee, resulting in a total of 40 joint examination angles. The means, standard deviations, intraclass correlation coefficients (I C C 3,k ), and Bland-Altman-Plots were calculated using MatLab for statistical analysis. RESULTS: Most measurement results were in accordance with expected joint RoMs. All examinations showed an acceptable repeatability. In active RoM examinations, the ICC of inter-rater reliability varied between 0.79 and 0.95. In passive RoM examination the ICC varied between 0.71 and 0.96, except examination angles at the elbow and knee extension (ICC: 0.0-0.77). CONCLUSION: The reliability and objectivity of active RoM examinations were improved by the measurement tool compared with examiners. In passive RoM examinations of upper and lower extremities, the increase of objectivity by the measurements was limited for some examination angles by external factors such as the individual examiner impact on motion execution or the given joint examination conditions. Especially the elbow joint examination requires further development to achieve acceptable reliability. A modification in the examination method to reduce the examiner impact on measurement and the implementation of a more complex calibration procedure could improve the objectivity and reliability of the measurement tool in passive joint RoM examination to be applicable on nearly the whole body.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Shoulder SEM and ICC for inter-rater reliability ranged from 4.2 to 7.8° and 0.71 to 0.99.
“SEM and ICC for inter-raterreliability ranged respectively from 4.2 to 7.8° and 0.71 to 0.99 [28,66].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [66]
Neck SEM and ICC for inter-rater reliability ranged from 1.2 to 9.4° and 0.64 to 0.99.
“Standard error of the mean (SEM) and ICC for inter-rater reliability ranged respectively from 1.2 to 9.4° and from 0.64 to 0.99 [64,65,66].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [66]
Both wrist reliability studies presented good to excellent intra-rater reliability for all joint movements (CMC and ICC 0.79 to 0.96).
“Both studies presented good to excellent intra-rater reliability for all joint movements (CMC and ICC between 0.79 to 0.96) [28,66].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [66]
Trunk reliability results are consistent and demonstrate good to excellent intra-rater reliability (ICC ≥0.8 except coronal plane fair to excellent 0.67 to 0.93).
“Results from these three studies are consistent and demonstrate good to excellent intra-rater reliability (ICC ≥ 0.8 except for coronal plane which is fair to excellent (0.67 to 0.93)) [46,66,68].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [66]
For elbow reliability, one study showed excellent reliability in every movement direction (CMC ≥0.9) and the other presented poor to good reliability (ICC = 0.2 to 0.77).
“One study showed excellent reliability in every movement direction (CMC ≥ 0.9) and the other presented poor to good reliability (ICC = 0.2 to 0.77) [28,66].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [66]
Hip intra-rater reliability is fair to excellent and inter-rater reliability varied across movements (good for walking ICC 0.4 to 0.74 and poor for jumping ICC ≤0.39).
“Intra-rater reliability is fair to excellent and inter-rater reliability varied across movements performed (good for walking [ICC of 0.4 to 0.74] and poor for jumping [ICC ≤ 0.39] [46,53,66]).”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [66]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965 · see citing works
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 23,433 · see citing works
Beckett, A. H., Rowland, M., & TURNER, P. (1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,917 · see citing works
A Design Framework for Instrumenting Analytic Provenance for Problem-Solving Tasks
Yang, L., Morizet‐Mahoudeaux, P., Guénand, A., & Mouloudi, A. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-981-10-8612-0_66 · Cited by 6,595 · see citing works
Wu, G., van der Helm, F. C. T., Veeger, H. E. J., Makhsous, M., Roy, P. V., Anglin, C., Nagels, J., Karduna, A. R., McQuade, K. J., Wang, X., et al. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.042 · Cited by 4,569 · see citing works
Grood, E. S., & Suntay, W. J. (1983) · Journal of Biomechanical Engineering · doi:10.1115/1.3138397 · Cited by 3,823 · see citing works
Wu, G., Siegler, S., Allard, P., Kirtley, C., Leardini, A., Rosenbaum, D., Whittle, M., DʼLima, D. D., Cristofolini, L., Witte, H., et al. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00222-6 · Cited by 3,249 · see citing works
Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed
Kottner, J., Audigé, L., Brorson, S., Donner, A. P., Gajewski, B. J., Hróbjartsson, A., Roberts, C., Shoukri, M. M., & Streiner, D. L. (2010) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2010.03.002 · Cited by 2,239 · see citing works
2006 IEEE International Conference on Robotics and Automation
(2005) · IEEE Transactions on Robotics · doi:10.1109/tro.2005.847362 · Cited by 1,115 · see citing works
Xiaoping, Y., Bachmann, E. R., & McGhee, R. B. (2008) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2007.911646 · Cited by 321 · see citing works
Functional calibration procedure for 3D knee joint angle description using inertial sensors
Favre, J., Aïssaoui, R., Jolles, B. M., de Guise, J. A., & Aminian, K. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.06.025 · Cited by 302 · see citing works
Joint Range of Motion and Muscle Length Testing
Reese, N. B., Bandy, W. D., & Yates, C. C. (2009) · Medical Entomology and Zoology · Cited by 267 · see citing works
Nussbaumer, S., Leunig, M., Item‐Glatthorn, J. F., Stauffacher, S., Gerber, H., & Maffiuletti, N. A. (2010) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-11-194 · Cited by 266 · see citing works
Surface movement errors in shank kinematics and knee kinetics during gait
Holden, J. P., Orsini, J. A., Siegel, K. L., Kepple, T. M., Gerber, L. H., & Stanhope, S. J. (1997) · Gait & Posture · doi:10.1016/s0966-6362(96)01088-0 · Cited by 180 · see citing works
Holm, I., Bolstad, B., Lütken, T., Ervik, A., Røkkum, M., & Steen, H. (2000) · Physiotherapy Research International · doi:10.1002/pri.204 · Cited by 161 · see citing works
Jordan, K. P. (2000) · British journal of rheumatology · doi:10.1093/rheumatology/39.4.382 · Cited by 122 · see citing works
An investigation of the effects of magnetic variations on inertial/magnetic orientation sensors
Bachmann, E. R., Yun, X., & Peterson, C. W. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2004.1307974 · Cited by 122 · see citing works
Vries, W. H. K. D., Veeger, H. E. J., Cutti, A. G., Baten, C. T. M., & van der Helm, F. C. T. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.03.007 · Cited by 104 · see citing works
Bergmann, J. H., Mayagoitia, R. E., & Smith, I. C. (2009) · Dynamic Medicine · doi:10.1186/1476-5918-8-3 · Cited by 88 · see citing works
Ha, T. H., Saber-Sheikh, K., Moore, A. P., & Jones, M. P. (2012) · Manual Therapy · doi:10.1016/j.math.2012.04.003 · Cited by 81 · see citing works
Amiri, M., Jull, G. A., & Bullock‐Saxton, J. E. (2003) · Manual Therapy · doi:10.1016/s1356-689x(03)00009-2 · Cited by 80 · see citing works
Accuracy and validity of observational estimates of wrist and forearm posture
Lowe, B. D. (2004) · Ergonomics · doi:10.1080/00140130310001653057 · Cited by 77 · see citing works
Do inertial sensors represent a viable method to reliably measure cervical spine range of motion?
Theobald, P. S., Jones, M. D., & Williams, J. M. (2011) · Manual Therapy · doi:10.1016/j.math.2011.06.007 · Cited by 74 · see citing works
Parel, I., Cutti, A. G., Fiumana, G., Porcellini, G., Verni, G., & Accardo, A. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2011.12.015 · Cited by 73 · see citing works
Accuracy and validity of observational estimates of shoulder and elbow posture
Lowe, B. D. (2004) · Applied Ergonomics · doi:10.1016/j.apergo.2004.01.003 · Cited by 65 · see citing works
A novel method for assessing the 3-D orientation accuracy of inertial/magnetic sensors
Faber, G. S., Chang, C.-C., Rizun, P., & Dennerlein, J. T. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.07.029 · Cited by 56 · see citing works
Workload Assessment in Field Using the Ambulatory CUELA System
Ellegast, R. P., Hermanns, I., & Schiefer, C. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02809-0_24 · Cited by 45 · see citing works
Self-citationOptimization of Inertial Sensor-Based Motion Capturing for Magnetically Distorted Field Applications
Schiefer, C., Ellegast, R. P., Hermanns, I., Kraus, T., Ochsmann, E., Larue, C., & Plamondon, A. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4028822 · Cited by 35 · see citing works
Self-citationA wearable inertial-sensing-based body sensor network for shoulder range of motion assessment
Hsu, Y., Wang, J.-S., Lin, Y., Chen, S., Tsai, Y.-J., Chu, C.-L., & Chang, C. (2013) · International Conference on Orange Technologies · doi:10.1109/icot.2013.6521225 · Cited by 21 · see citing works
Einfache Messmethode der HWS-Funktion nach der Neutral-Null-Methode
Wolff, H.-D., & Lonquich, C. (2000) · Manuelle Medizin · doi:10.1007/s003370070014 · Cited by 10 · see citing works
Spallek, M., Kuhn, W., Schwarze, S., & Hartmann, B. (2007) · Journal of Occupational Medicine and Toxicology · doi:10.1186/1745-6673-2-12 · Cited by 10 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review
Poitras, I., Dupuis, F., Bielmann, M., Campeau-Lecours, A., Mercier, C., Bouyer, L., & Roy, J.-S. (2019) · Sensors · doi:10.3390/s19071555 · Cited by 309 · see citing works
Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review
Walmsley, C. P., Williams, S. A., Grisbrook, T., Elliott, C., Imms, C., & Campbell, A. (2018) · Sports Medicine - Open · doi:10.1186/s40798-018-0167-7 · Cited by 123 · see citing works
A narrative review on contemporary and emerging uses of inertial sensing in occupational ergonomics
Lim, S. I., & D’Souza, C. (2020) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2020.102937 · Cited by 112 · see citing works
van der Straaten, R., Baets, L. D., Jonkers, I., & Timmermans, A. A. A. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.10.005 · Cited by 54 · see citing works
Seidel, D. H., Ditchen, D. M., Hoehne-Hückstädt, U. M., Rieger, M. A., & Steinhilber, B. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16010130 · Cited by 43 · see citing works
Bessone, V., Höschele, N., Schwirtz, A., & Seiberl, W. (2019) · Sports Biomechanics · doi:10.1080/14763141.2019.1671486 · Cited by 40 · see citing works
Beshara, P., Anderson, D., Pelletier, M. H., & Walsh, W. R. (2021) · Sensors · doi:10.3390/s21248186 · Cited by 39 · see citing works
Baets, L. D., van der Straaten, R., Matheve, T., & Timmermans, A. A. A. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.06.025 · Cited by 41 · see citing works
Lind, C. M., Forsman, M., & Rose, L. M. (2019) · Ergonomics · doi:10.1080/00140139.2019.1710576 · Cited by 37 · see citing works
Beshara, P., Chen, J. F., Read, A. C., Lagadec, P., Wang, T., & Walsh, W. R. (2020) · Sensors · doi:10.3390/s20247238 · Cited by 37 · see citing works
Wu, Y., Tao, K., Chen, Q., Tian, Y., & Sun, L. (2022) · Sensors · doi:10.3390/s22186954 · Cited by 27 · see citing works
Kwon, Y., Lee, Y.-K., Kilic‐Berkmen, G., Lim, H., Scorr, L., Jinnah, H. A., & Yeo, W. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201900458 · Cited by 23 · see citing works
Santospagnuolo, A., Bruno, A. A., Pagnoni, A., Martello, F., Santoboni, F., Perroni, F., Vulpiani, M. C., & Vetrano, M. (2019) · The Journal of Sports Medicine and Physical Fitness · doi:10.23736/s0022-4707.19.09331-9 · Cited by 16 · see citing works
Baets, L. D., Vanbrabant, S., Dierickx, C., van der Straaten, R., & Timmermans, A. A. A. (2020) · Sensors · doi:10.3390/s20030876 · Cited by 16 · see citing works
Anoro-Hervera, A., Lafuente-Pérez, A., Navarro-Fernández, G., Muñoz‐García, D., Lara, S. L., & Beltrán-Alacreu, H. (2019) · Expert Review of Medical Devices · doi:10.1080/17434440.2019.1696675 · Cited by 14 · see citing works
Real-time representation of the human spine with absolute orientation sensors
Antonya, C., Butnariu, S., & Pozna, C. R. (2016) · International Conference on Control, Automation, Robotics and Vision (ICARCV) · doi:10.1109/icarcv.2016.7838745 · Cited by 11 · see citing works
Elizagaray-García, I., Gil‐Martínez, A., Navarro-Fernández, G., Navarro-Moreno, A. R., Sánchez-de-Toro-Hernández, J., de Terán, J. D., & Lara, S. L. (2021) · EXCLI journal · doi:10.17179/excli2021-3799 · Cited by 9 · see citing works
‘DIGITS’ app - smartphone augmented reality for hand telerehabilitation
Dong, H., Ho, E. Y. T., Shin, H., Banerjee, T., Masschelein, G., Davidson, J., de Ribaupierre, S., Eagleson, R. A., & Symonette, C. J. (2021) · Computer Methods in Biomechanics and Biomedical Engineering Imaging & Visualization · doi:10.1080/21681163.2021.1998927 · Cited by 8 · see citing works
Narejo, A., Baqai, A., Sikandar, N., Ali, A., & Narejo, S. (2020) · International Journal of Advanced Computer Science and Applications · doi:10.14569/ijacsa.2020.0110953 · Cited by 7 · see citing works
Bonfiglio, A., Farella, E., & Bongers, R. M. (2024) · IEEE International Conference on Omni-layer Intelligent Systems (COINS) · doi:10.1109/coins61597.2024.10622124 · Cited by 6 · see citing works
Bonfiglio, A., Farella, E., Tacconi, D., & Bongers, R. M. (2024) · Journal of Applied Biomechanics · doi:10.1123/jab.2023-0276 · Cited by 6 · see citing works
Scherff, E., Schnell, S., Siebert, T., & D'Souza, S. S. (2024) · Journal of Children s Orthopaedics · doi:10.1177/18632521241234768 · Cited by 4 · see citing works
Igwesi-Chidobe, C. N., Anih, E. U., Emmanuel, G. N., & Ozumba, B. C. (2025) · F1000Research · doi:10.12688/f1000research.160172.2 · Cited by 1 · see citing works
A review on measuring cervical range of motion using an inertial measurement unit
Yim, J., Kim, H., Park, Y.-J., & Park, Y.-B. (2017) · 대한한의학회지 · doi:10.13048/jkm.17006 · Cited by 1 · see citing works
Technologies Applied for Elbow Joint Angle Measurements: A Systematic Review
Rezende, A. R., Alves, C. M., Marques, I. A., Silva, D. C., de Paiva, T. S., & Naves, E. L. M. (2022) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-030-70601-2_39 · Cited by 1 · see citing works
Leonet-Tijero, L., Corral-de-Toro, J., Rodríguez‐Sanz, J., Hernández-Secorún, M., Abenia-Benedí, H., Lucha-López, M. O., Monti-Ballano, S., Müller-Thyssen-Uriarte, J., Tricás-Vidal, H. J., Hidalgo-García, C., et al. (2022) · Diagnostics · doi:10.3390/diagnostics12020546
Revisão sistemática da usabilidade em dispositivos médicos
Roma, M. S. G. (2016) · doi:10.26512/2016.07.d.21641
Çil, E. T., Gökçek, G. G., Şerif, T., Subaşı, F., & Şaylı, U. (2023) · Archives of Physical Health and Sports Medicine · doi:10.22259/2639-1805.0501002
Eom, S.-Y., Lee, D.-W., & Park, D.-S. (2025) · Physical therapy rehabilitation science · doi:10.14474/ptrs.2025.14.1.102
Bonfiglio, A., Farella, E., & Bongers, R. M. (2025) · Journal of Applied Biomechanics · doi:10.1123/jab.2024-0283
Mohokum, M., Klotz, L., Weber, B., Griemsmann, S., Wechsler, K., Hermanns-Truxius, I., & Ellegast, R. P. (2026) · MSK – Muskuloskelettale Physiotherapie · doi:10.1055/a-2769-6467
Self-citation
- Authors
- Schiefer, C., Kraus, T., Ellegast, R. P., & Ochsmann, E.
- Affiliations
- Institut für Arbeitsschutz der Deutschen Gesetzlichen Unfallversicherung (DE)
- RWTH Aachen University (DE)
- Westsächsische Hochschule Zwickau (DE)
- Corresponding author
- Schiefer, Christoph
- Venue
- Journal of Occupational Medicine and Toxicology
- Published
- 2015-04-29
- Volume
- 10
- Issue
- 1
- Pages
- 16-16
- ISSN
- 1745-6673 (ISSN-L)
- PMC
- PMC4433057
- OpenAlex
- W2141111879
- Cited by
- 31
- References
- 31
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 3 · 2023: 1 · 2022: 3 · 2021: 3 · 2020: 4 · 2019: 7 · 2018: 1 · 2017: 3 · 2016: 2
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Journal of Occupational Medicine and Toxicology (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- RWTH Publications (RWTH Aachen) (submittedVersion, cc-by)
- RWTH Publications (RWTH Aachen)
- Funders
- Deutsche Gesetzliche Unfallversicherung
- RWTH Aachen University
- Topics
- Health Sciences › Medicine › Rehabilitation › Musculoskeletal Disorders and Rehabilitation
- Social Sciences › Psychology › Social Psychology › Ergonomics and Musculoskeletal Disorders
- Health Sciences › Medicine › Pharmacology › Musculoskeletal pain and rehabilitation
- Keywords
- range of motion, inertial sensors, inter-rater reliability, functional diagnosis, occupational medical examination, passive range of motion, active range of motion, upper and lower extremities
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review