ArtiaX : An electron tomography toolbox for the interactive handling of s ub‐tomograms in UCSF ChimeraX
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Cryo‐electron tomography analysis involves the selection of macromolecular complexes to be used for subsequent sub‐tomogram averaging and structure determination. Here, we describe a plugin developed for UCSF ChimeraX that allows for the display, selection, and editing of particles within tomograms. Positions and orientations of selected particles can be manually set, modified and inspected in real time, both on screen and in virtual reality, and exported to various file formats. The plugin allows for the parallel visualization of particles stored in several meta data lists, in the context of any three‐dimensional image that can be opened with UCSF ChimeraX. The particles are rendered in user‐defined colors or using colormaps, such that individual classes or groups of particles, cross‐correlation coefficients, or other types of information can be highlighted to the user. The implemented functions are fast, reliable, and intuitive, exploring the broad range of features in UCSF ChimeraX. They allow for a fluent human–machine interaction, which enables an effective understanding of the sub‐tomogram processing pipeline, even for non‐specialist users.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
UCSF Chimera—A visualization system for exploratory research and analysis
Pettersen, E. F., Goddard, T. D., Huang, C. C., Couch, G. S., Greenblatt, D. M., Meng, E. C., & Ferrin, T. E. (2004) · Journal of Computational Chemistry · doi:10.1002/jcc.20084 · Cited by 45,828 · cited 2×
“21,26 Since the inception of its predecessor, UCSF Chimera, 31 the scope of both platforms has continuously expanded towards electron microscopy image data.”
BackgroundUCSF ChimeraX: Structure visualization for researchers, educators, and developers
Pettersen, E. F., Goddard, T. D., Huang, C. C., Meng, E. C., Couch, G. S., Croll, T. I., Morris, J. H., & Ferrin, T. E. (2021) · Protein Science · doi:10.1002/pro.3943 · Cited by 9,514
Computer Visualization of Three-Dimensional Image Data Using IMOD
Kremer, J. R., Mastronarde, D. N., & McIntosh, J. R. (1996) · Journal of Structural Biology · doi:10.1006/jsbi.1996.0013 · Cited by 5,611
UCSF ChimeraX: Meeting modern challenges in visualization and analysis
Goddard, T. D., Huang, C. C., Meng, E. C., Pettersen, E. F., Couch, G. S., Morris, J. H., & Ferrin, T. E. (2018) · Protein Science · doi:10.1002/pro.3235 · Cited by 5,267 · cited 4×
“Here, we present an open-source toolbox, ArtiaX, that was developed on the platform of UCSF ChimeraX (“ChimeraX” hereafter).(21,26) Our plugin allows for a fluent human–machine interaction as well as an improved visualization of cryoET-related tasks and explores the VR capabilities of ChimeraX.”
BackgroundMethodInfluentialEMAN2: An extensible image processing suite for electron microscopy
Tang, G., Peng, L., Baldwin, P. R., Mann, D. S., Jiang, W., Rees, I., & Ludtke, S. J. (2007) · Journal of Structural Biology · doi:10.1016/j.jsb.2006.05.009 · Cited by 2,994 · cited 1×
“Previously, this was solved by creating intermediate, static surface representations of the particle, 11 resampling the rotated and shifted maps on the grid of the tomograms, 19 or rendering each surface individually (default for density maps in ChimeraX).”
MethodKhalifa, A. A. Z., Ichikawa, M., Dai, D., Kubo, S., Black, C. S., Peri, K., McAlear, T. S., Veyron, S., Yang, S. K., Vargas, J., et al. (2020) · eLife · doi:10.7554/elife.52760 · Cited by 1,676
Structural Mechanism for Rifampicin Inhibition of Bacterial RNA Polymerase
Campbell, E. A., Korzheva, N., Mustaev, A., Murakami, K., Nair, S., Goldfarb, A., & Darst, S. A. (2001) · Cell · doi:10.1016/s0092-8674(01)00286-0 · Cited by 1,556 · cited 2×
“For visualization, surfaces were generated from PDB-7 K00, 43 PDB-1PCQ, 44 and PDB-1I6V, 45 respectively, using the Chi-meraX “ molmap ” -command at a resolution of 20 Å. Reconstructed tomograms of the EMPIAR-10304 and the Mycoplasma genitalium cell, as well as the respective particle lists have been deposited to the…”
MethodInfluentialStructures of the Bacterial Ribosome at 3.5 Å Resolution
Schuwirth, B. S., Borovinskaya, M. A., Hau, C. W., Zhang, W., Vila-Sanjurjo, A., Holton, J. M., & Cate, J. H. D. (2005) · Science · doi:10.1126/science.1117230 · Cited by 1,418
Real-time cryo-electron microscopy data preprocessing with Warp
Tegunov, D., & Cramer, P. (2019) · Nature Methods · doi:10.1038/s41592-019-0580-y · Cited by 1,332
The Molecular Architecture of Axonemes Revealed by Cryoelectron Tomography
Nicastro, D., Schwartz, C., Pierson, J., Gaudette, R., Porter, M. E., & McIntosh, J. R. (2006) · Science · doi:10.1126/science.1128618 · Cited by 879 · cited 1×
“In the context of cryoET processing pipelines, the information on individual particles is typically stored in text-based or binary metadata files (called particle or motive-lists), which are input to or output of subtomogram averaging or classification procedures.(5,6,8,9) Several metadata are stored, including the 3D…”
Backgroundamira: A Highly Interactive System for Visual Data Analysis
STALLING, D., WESTERHOFF, M., & HEGE, H.-C. (2005) · Visualization Handbook · doi:10.1016/b978-012387582-2/50040-x · Cited by 569
Focused-ion-beam thinning of frozen-hydrated biological specimens for cryo-electron microscopy
Marko, M., Hsieh, C., Schalek, R., Frank, J., & Mannella, C. (2007) · Nature Methods · doi:10.1038/nmeth1014 · Cited by 539
Wickham, M. E. (2001) · The EMBO Journal · doi:10.1093/emboj/20.20.5636 · Cited by 514
Castaño-Díez, D., Kudryashev, M., Arheit, M., & Stahlberg, H. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2011.12.017 · Cited by 509 · cited 1×
“The plugin allows for performant, interactive display of cryo-tomograms and associated metadata in the most common file formats (AV3/TOM package 27 and IMOD/ PEET 6 motive lists, RELION STAR files, 28,29 and Dynamo tables 10,17 ).”
MethodMulti-particle cryo-EM refinement with M visualizes ribosome-antibiotic complex at 3.5 Å in cells
Tegunov, D., Xue, L., Dienemann, C., Cramer, P., & Mahamid, J. (2021) · Nature Methods · doi:10.1038/s41592-020-01054-7 · Cited by 509
Focused ion beam micromachining of eukaryotic cells for cryoelectron tomography
Rigort, A., Bäuerlein, F. J. B., Villa, E., Eibauer, M., Laugks, T., Baumeister, W., & Plitzko, J. M. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201333109 · Cited by 430 · cited 1×
“13 At the same time, advances in sample preparation techniques, such as cryogenic focused ion beam milling (cryo-FIB-SEM), 14 – 16 have allowed researchers to routinely acquire tomograms of native — thicker — specimens of eukaryotic cells.”
BackgroundConvolutional neural networks for automated annotation of cellular cryo-electron tomograms
Chen, M., Dai, W., Sun, S. Y., Jonasch, D., He, C. Y., Schmid, M. F., Chiu, W., & Ludtke, S. J. (2017) · Nature Methods · doi:10.1038/nmeth.4405 · Cited by 398
A Bayesian approach to single-particle electron cryo-tomography in RELION-4.0
Zivanov, J., Otón, J., Ke, Z., von Kügelgen, A., Pyle, E., Qu, K., Morado, D., Castaño-Díez, D., Zanetti, G., Bharat, T. A., et al. (2022) · eLife · doi:10.7554/elife.83724 · Cited by 339
Retrovirus envelope protein complex structure in situ studied by cryo-electron tomography
Förster, F., Medalia, O., Zauberman, N., Baumeister, W., & Fass, D. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0409178102 · Cited by 302 · cited 1×
“The plugin allows for performant, interactive display of cryo-tomograms and associated metadata in the most common file formats (AV3/TOM package 27 and IMOD/ PEET 6 motive lists, RELION STAR files, 28,29 and Dynamo tables 10,17 ).”
MethodemClarity: software for high-resolution cryo-electron tomography and subtomogram averaging
Himes, B. A., & Zhang, P. (2018) · Nature Methods · doi:10.1038/s41592-018-0167-z · Cited by 283 · cited 1×
“In the context of cryoET processing pipelines, the information on individual particles is typically stored in text-based or binary metadata files (called particle or motive-lists), which are input to or output of subtomogram averaging or classification procedures.(5,6,8,9) Several metadata are stored, including the 3D…”
BackgroundIdentification of macromolecular complexes in cryoelectron tomograms of phantom cells
Frangakis, A. S., Böhm, J., Förster, F., Nickell, S., Nicastro, D., Typke, D., Hegerl, R., & Baumeister, W. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.172520299 · Cited by 267 · cited 1×
“37,38 Particle locations and orientations were determined using template matching 23 using the density map EMD-10211 as a reference.”
MethodSelf-citationStructure of the bacterial ribosome at 2 Å resolution
Watson, Z. L., Ward, F. R., Méheust, R., Ad, O., Schepartz, A., Banfield, J. F., & Cate, J. H. (2020) · eLife · doi:10.7554/elife.60482 · Cited by 263
Hrabe, T., Chen, Y., Pfeffer, S., Kuhn Cuellar, L., Mangold, A.-V., & Förster, F. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2011.12.003 · Cited by 260 · cited 3×
“In the context of cryoET processing pipelines, the information on individual particles is typically stored in text-based or binary metadata files (called particle or motive-lists), which are input to or output of subtomogram averaging or classification procedures.(5,6,8,9) Several metadata are stored, including the 3D…”
BackgroundMethodA complete data processing workflow for cryo-ET and subtomogram averaging
Chen, M., Bell, J. M., Shi, X., Sun, S. Y., Wang, Z., & Ludtke, S. J. (2019) · Nature Methods · doi:10.1038/s41592-019-0591-8 · Cited by 253 · cited 1×
“In the context of cryoET processing pipelines, the information on individual particles is typically stored in text-based or binary metadata files (called particle or motive-lists), which are input to or output of subtomogram averaging or classification procedures.(5,6,8,9) Several metadata are stored, including the 3D…”
BackgroundElectron tomography: towards visualizing the molecular organization of the cytoplasm
Baumeister, W. (2002) · Current Opinion in Structural Biology · doi:10.1016/s0959-440x(02)00378-0 · Cited by 228 · cited 2×
“(2) At the stage of inspection of particles after processing— outliers can be interactively rejected.”
BackgroundClustering and variance maps for cryo-electron tomography using wedge-masked differences
Heumann, J. M., Hoenger, A., & Mastronarde, D. N. (2011) · Journal of Structural Biology · doi:10.1016/j.jsb.2011.05.011 · Cited by 220
Bharat, T. A. M., Russo, C. J., Löwe, J., Passmore, L. A., & Scheres, S. H. W. (2015) · Structure · doi:10.1016/j.str.2015.06.026 · Cited by 195 · cited 1×
“The plugin allows for performant, interactive display of cryo-tomograms and associated metadata in the most common file formats (AV3/TOM package 27 and IMOD/ PEET 6 motive lists, RELION STAR files, 28,29 and Dynamo tables 10,17 ).”
MethodDeep learning improves macromolecule identification in 3D cellular cryo-electron tomograms
Moebel, E., Martinez-Sanchez, A., Lamm, L., Righetto, R. D., Wietrzynski, W., Albert, S., Larivière, D., Fourmentin, E., Pfeffer, S., Ortiz, J., et al. (2021) · Nature Methods · doi:10.1038/s41592-021-01275-4 · Cited by 189
Chaudhry, C., Farr, G. W., Todd, M. J., Rye, H. S., Brünger, A. T., Adams, P. D., Horwich, A. L., & Sigler, P. B. (2003) · The EMBO Journal · doi:10.1093/emboj/cdg477 · Cited by 148 · cited 2×
“For visualization, surfaces were generated from PDB-7 K00, 43 PDB-1PCQ, 44 and PDB-1I6V, 45 respectively, using the Chi-meraX “ molmap ” -command at a resolution of 20 Å. Reconstructed tomograms of the EMPIAR-10304 and the Mycoplasma genitalium cell, as well as the respective particle lists have been deposited to the…”
MethodInfluentialCastaño‐Díez, D., Kudryashev, M., & Stahlberg, H. (2016) · Journal of Structural Biology · doi:10.1016/j.jsb.2016.06.005 · Cited by 145 · cited 1×
“The plugin allows for performant, interactive display of cryo-tomograms and associated metadata in the most common file formats (AV3/TOM package 27 and IMOD/ PEET 6 motive lists, RELION STAR files, 28,29 and Dynamo tables 10,17 ).”
MethodCharacterization of Fully Recombinant Human 20S and 20S-PA200 Proteasome Complexes
Toste Rêgo, A., & da Fonseca, P. C. A. (2019) · Molecular Cell · doi:10.1016/j.molcel.2019.07.014 · Cited by 118 · cited 1×
“atomic model of the human 20 S proteasome (PDB 6RGQ).(46)”
BackgroundMaturation of the matrix and viral membrane of HIV-1
Qu, K., Ke, Z., Zila, V., Anders-Össwein, M., Glass, B., Mücksch, F., Müller, R., Schultz, C., Müller, B., Kräusslich, H.-G., et al. (2021) · Science · doi:10.1126/science.abe6821 · Cited by 106
Improved applicability and robustness of fast cryo-electron tomography data acquisition
Eisenstein, F., Danev, R., & Pilhofer, M. (2019) · Journal of Structural Biology · doi:10.1016/j.jsb.2019.08.006 · Cited by 93
A visualization and segmentation toolbox for electron microscopy
Pruggnaller, S., Mayr, M., & Frangakis, A. S. (2008) · Journal of Structural Biology · doi:10.1016/j.jsb.2008.05.003 · Cited by 89 · cited 1×
“Previously, this was solved by creating intermediate, static surface representations of the particle, 11 resampling the rotated and shifted maps on the grid of the tomograms, 19 or rendering each surface individually (default for density maps in ChimeraX).”
MethodSelf-citationPractical workflow for cryo focused-ion-beam milling of tissues and cells for cryo-TEM tomography
Hsieh, C., Schmelzer, T., Kishchenko, G. P., Wagenknecht, T., & Marko, M. (2013) · Journal of Structural Biology · doi:10.1016/j.jsb.2013.10.019 · Cited by 85 · cited 1×
“13 At the same time, advances in sample preparation techniques, such as cryogenic focused ion beam milling (cryo-FIB-SEM), 14 – 16 have allowed researchers to routinely acquire tomograms of native — thicker — specimens of eukaryotic cells.”
BackgroundFörster, F. G., Han, B.-G., & Beck, M. (2010) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(10)83011-3 · Cited by 83 · cited 1×
“Other commonly employed methods for particle selection are purely computational, such as template matching (offered in Dynamo, 17 Warp/M, 7,22 pyTom, 5 emClarity, 8 EMAN2 9 or molmatch 23,24 ), or neural networks (offered by EMAN2 19 or DeepFinder 25 ).”
MethodComputational exploration of structural information from cryo-electron tomograms
Frangakis, A. S., & Förster, F. G. (2004) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2004.04.003 · Cited by 73 · cited 2×
“The toolbox improves current software solutions in three ways: (1) At the stage of selection and inspection of putative positions of various particles for further processing—they can be selected in 2D and 3D and their orientation can be set in an efficient manner using virtual reality (VR) capabilities.”
BackgroundMethodSelf-citationSteven, A. C., & Baumeister, W. P. (2008) · Journal of Structural Biology · doi:10.1016/j.jsb.2008.06.002 · Cited by 72 · cited 1×
“(3) In terms of user experience—interactive real-time visualization of cryoET data is made available even to non-specialist users and without requiring specialized or commercial software, enabling sharing of data with a broader audience.”
BackgroundElectron tomography of viruses
Subramaniam, S., Bartesaghi, A., Liu, J., Bennett, A. E., & Sougrat, R. (2007) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2007.09.009 · Cited by 67
Resolution improvement by 3D particle averaging in localization microscopy
Broeken, J., Johnson, H., Lidke, D. S., Liu, S., Nieuwenhuizen, R. P. J., Stallinga, S., Lidke, K. A., & Rieger, B. (2015) · Methods and Applications in Fluorescence · doi:10.1088/2050-6120/3/1/014003 · Cited by 57 · cited 1×
“3D single molecule fluorescence microscopy techniques utilize analysis methods similar to those in cryoET 32 – 34 and thus require similar tools.”
Method3D particle averaging and detection of macromolecular symmetry in localization microscopy
Heydarian, H., Joosten, M., Przybylski, A., Schueder, F., Jungmann, R., van Werkhoven, B., Keller‐Findeisen, J., Ries, J., Stallinga, S., Bates, M., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-22006-5 · Cited by 51
Three-dimensional CTF correction improves the resolution of electron tomograms
Kunz, M., & Frangakis, A. S. (2016) · Journal of Structural Biology · doi:10.1016/j.jsb.2016.06.016 · Cited by 49 · cited 2×
“4 Å using super-sampled SART.(37,38) Particle locations and orientations were determined using template matching(23) using the density map EMD-10211 as a reference.”
MethodInfluentialSelf-citationSabinina, V. J., Hossain, M. J., Hèriché, J.-K., Hoess, P., Nijmeijer, B., Mosalaganti, S., Kueblbeck, M., Callegari, A., Szymborska, A., Beck, M., et al. (2021) · Molecular Biology of the Cell · doi:10.1091/mbc.e20-11-0728 · Cited by 47
Step-by-step guide to efficient subtomogram averaging of virus-like particles with Dynamo
Scaramuzza, S., & Castaño‐Díez, D. (2021) · PLoS Biology · doi:10.1371/journal.pbio.3001318 · Cited by 43 · cited 1×
“This functionality was specifically intended for object selection in 3D images(21) and is integrated into several cryoET processing pipelines for the purpose of particle selection.(5,30) However, the “MarkerSet”-interface models individual particles as points and is as such not designed to include or render informatio…”
MethodSuper-sampling SART with ordered subsets
Kunz, M., & Frangakis, A. S. (2014) · Journal of Structural Biology · doi:10.1016/j.jsb.2014.09.010 · Cited by 41 · cited 2×
“4 Å using super-sampled SART.(37,38) Particle locations and orientations were determined using template matching(23) using the density map EMD-10211 as a reference.”
MethodInfluentialSelf-citationScheffer, M. P., González‐González, L., Seybert, A., Ratera, M., Kunz, M., Valpuesta, J., Fita, I., Querol, E., Piñol, J., Martín‐Benito, J., et al. (2017) · Molecular Microbiology · doi:10.1111/mmi.13743 · Cited by 30 · cited 1×
“40 Locations and orientations of the major surface adhesion complex (NAP) were used as determined by previous sub-tomogram alignment and averaging, 41 and visualized using the resulting average density map EMD-20259, 42 low-pass filtered to a resolution of 20 Å. Locations and orientations of…”
MethodSelf-citationSeybert, A., González‐González, L., Scheffer, M. P., Lluch‐Senar, M., Mariscal, A. M., Querol, E., Matthäus, F., Piñol, J., & Frangakis, A. S. (2018) · Molecular Microbiology · doi:10.1111/mmi.13938 · Cited by 27
Self-citationMean curvature motion facilitates the segmentation and surface visualization of electron tomograms
Frangakis, A. S. (2022) · Journal of Structural Biology · doi:10.1016/j.jsb.2022.107833 · Cited by 11 · cited 1×
“The segmentation of the cell membrane was post-processed using mean curvature motion smoothing.(40) Locations and orientations of the major surface adhesion complex (NAP) were used as determined by previous sub-tomogram alignment and averaging,(41) and visualized using the resulting average density map EMD-20259,(42)…”
MethodSelf-citation
Cited by
UCSF ChimeraX: Tools for structure building and analysis
Meng, E. C., Goddard, T. D., Pettersen, E. F., Couch, G. S., Pearson, Z. J., Morris, J. H., & Ferrin, T. E. (2023) · Protein Science · doi:10.1002/pro.4792 · Cited by 4,442
In-cell architecture of the mitochondrial respiratory chain
Waltz, F., Righetto, R. D., Kelley, R., Zhang, X., Obr, M., Khavnekar, S., Kotecha, A., & Engel, B. D. (2024) · doi:10.1101/2024.09.03.610704 · Cited by 96
In-cell architecture of the mitochondrial respiratory chain
Waltz, F., Righetto, R. D., Lamm, L., Salinas-Giegé, T., Kelley, R., Zhang, X., Obr, M., Khavnekar, S., Kotecha, A., & Engel, B. D. (2025) · Science · doi:10.1126/science.ads8738 · Cited by 95
Structure of the native γ-tubulin ring complex capping spindle microtubules
(2024) · doi:10.1038/s41594-024-01281-y · Cited by 38
Cryo-electron tomography pipeline for plasma membranes
Sun, W. W., Michalak, D. J., Sochacki, K. A., Kunamaneni, P., Alfonzo-Méndez, M. A., Arnold, A. M., Strub, M.-P., Hinshaw, J. E., & Taraska, J. W. (2025) · Nature Communications · doi:10.1038/s41467-025-56045-z · Cited by 35
Metadata
- Authors
- Ermel, U. H., Arghittu, S. M., & Frangakis, A. S.
- Venue
- Protein Science
- Publisher
- Wiley
- Published
- 2022-11-16
- Volume
- 31
- Issue
- 12
- Pages
- e4472-e4472
- ISSN
- 0961-8368 (ISSN-L)
- 1469-896X
- OpenAlex
- W4306630453
- Cited by
- 167
- References
- 48
- FWCI
- 12.42
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.