CoChat

Accelerated high‐sensitivity microsequencing of proteins and peptides using a miniature reaction cartridge

Open access
Totty, Nicholas F., Hsuan, J. Justin, Waterfield, Michael D. · 1992 · Protein Science
Cited by 72

The DOI matches its Crossref record.

Abstract

Greatly reduced automated protein sequencing degradation times of less than 25 min with concurrent on‐line phenylthiohydantoin (PTH) derivative analysis times of less than 16 min have been achieved by using a miniaturized reaction cartridge with optimized chemical and analytical cycles. Using this method a wide range of standard and novel peptides and proteins have been sequenced with reproducibly high initial and repetitive cycle yields. In these accelerated analyses the recovery of the more labile PTH derivatives was markedly improved by using elevated pressure during cleavage steps and temperature programming throughout the Edman cycle.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/pro.5560010914

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 72

Metadata

Authors
Totty, N. F., Hsuan, J. J., & Waterfield, M. D.
Venue
Protein Science
Publisher
Wiley
Published
1992-09
Volume
1
Issue
9
Pages
1215-1224
ISSN
  • 0961-8368 (ISSN-L)
  • 1469-896X
OpenAlex
W2169838115
Cited by
72
References
0
FWCI
4.33
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accelerated high‐sensitivity microsequencing of proteins and peptides using a miniature reaction cartridge. https://app.cochat.ai/papers/10.1002/pro.5560010914
The paper
Totty, N. F., Hsuan, J. J., & Waterfield, M. D. (1992). Accelerated high‐sensitivity microsequencing of proteins and peptides using a miniature reaction cartridge. Protein Science. https://doi.org/10.1002/pro.5560010914

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.