Is a quantum biosensing revolution approaching? Perspectives in NV-assisted current and thermal biosensing in living cells
Open accessThe DOI matches its Crossref record; 185 of the 185 references it cites were found in a registry or an index.
Abstract
Understanding the human brain is one of the most significant challenges of the 21st century. As theoretical studies continue to improve the description of the complex mechanisms that regulate biological processes, in parallel numerous experiments are conducted to enrich or verify these theoretical predictions also with the aim of extrapolating more accurate models. In the fields of magnetometry and thermometry, among the various sensors proposed for biological application, nitrogen‐vacancy (NV) centers are emerging as a promising solution due to their perfect biocompatibility and the possibility of being positioned in close proximity to the cell membrane, thus allowing a nanometric spatial resolution down to the nano‐scale. Still many issues must be overcome to obtain either a sensitivity capable of revealing the very weak electromagnetic fields generated by neurons (or other excitable cells) during their firing activity or a spatial resolution sufficient to measure intracellular thermal gradient due to biological processes. However, over the last few years, significant improvements have been achieved in this direction, thanks to the use of innovative techniques. In this review, the new results regarding the application of NV centers will be analyzed and the main challenges that must be afforded for leading to practical applications will be discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Millisecond-timescale, genetically targeted optical control of neural activity
Boyden, E. S., Zhang, F., Bamberg, E., Nagel, G., & Deisseroth, K. (2005) · Nature Neuroscience · doi:10.1038/nn1525 · Cited by 4,861
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
The nitrogen-vacancy colour centre in diamond
Doherty, M. W., Manson, N. B., Delaney, P., Jelezko, F., Wrachtrup, J., & Hollenberg, L. C. L. (2013) · Physics Reports · doi:10.1016/j.physrep.2013.02.001 · Cited by 2,866
The properties and applications of nanodiamonds
Mochalin, V. N., Shenderova, O., Ho, D., & Gogotsi, Y. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2011.209 · Cited by 2,745
The NEURON Simulation Environment
Hines, M. L., & Carnevale, N. T. (1997) · Neural Computation · doi:10.1162/neco.1997.9.6.1179 · Cited by 2,658
(1995) · Springer eBooks · doi:10.1007/978-1-4419-1229-9 · Cited by 2,526
Nanoscale imaging magnetometry with diamond spins under ambient conditions
Balasubramanian, G., Chan, I. Y., Kolesov, R., Al-Hmoud, M., Tisler, J., Shin, C., Kim, C., Wojcik, A., Hemmer, P. R., Krueger, A., et al. (2008) · Nature · doi:10.1038/nature07278 · Cited by 1,999
Nanoscale magnetic sensing with an individual electronic spin in diamond
Maze, J. R., Stanwix, P. L., Hodges, J. S., Hong, S., Taylor, J. M., Cappellaro, P., Jiang, L., Dutt, M. V. G., Togan, E., Zibrov, A. S., et al. (2008) · Nature · doi:10.1038/nature07279 · Cited by 1,984
High-sensitivity diamond magnetometer with nanoscale resolution
Taylor, J. M., Cappellaro, P., Childress, L., Jiang, L., Budker, D., Hemmer, P. R., Yacoby, A., Walsworth, R., & Lukin, M. D. (2008) · Nature Physics · doi:10.1038/nphys1075 · Cited by 1,959
Nanometre-scale thermometry in a living cell
Kucsko, G., Maurer, P. C., Yao, N. Y., Kubo, M., Noh, H. J., Lo, P. K., Park, H., & Lukin, M. D. (2013) · Nature · doi:10.1038/nature12373 · Cited by 1,951
Research works printed but not linked: 10
- Waxman S. G., 1998, N. Engl. J. Med., 338, 323
- E. A.Kiyatkin Handbook of Clinical Neurology vol. 157 Elsevier 2018 pp.483–504.
- E.Bernardi E.Moreva P.Traina G.Petrini S. D.Tchernij J.Forneris Z.Pastuovic I. P.Degiovanni P.Olivero M.Genovese arXiv:2005.13230 2020. · arXiv
- H. C.Davis P.Ramesh A.Bhatnagar A.Lee‐Gosselin J. F.Barry D. R.Glenn R. L.Walsworth M. G.Shapiro arXiv:1610.01924 2016. · arXiv
- Bauch E., 2018, Phys. Rev. X, 8, 031025
- E.Bauch S.Singh J.Lee C. A.Hart J. M.Schloss M. J.Turner J. F.Barry L.Pham N.Bar‐Gill S. F.Yelin et al. arXiv:1904.08763 2019. · arXiv
- Toyli D., 2012, Phys. Rev. X, 2, 031001
- B.Kuhn F.Picollo V.Carabelli G.Rispoli Advanced real time recordings of neuronal activity Pflügers Archiv: European Journal of Physiology submitted.
- Nicol J., 1948, Q. J. Microsc. Sci., 3, 1
- Achard J., 2020, J. Phys. D: Appl. Phys.
Cited by
Diamond quantum thermometry: from foundations to applications
Fujiwara, M., & Shikano, Y. (2021) · Nanotechnology · doi:10.1088/1361-6528/ac1fb1 · Cited by 137
Navigating the landscape of optical biosensors
Shrikrishna, N. S., Sharma, R., Sahoo, J., Kaushik, A. K., & Gandhi, S. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.151661 · Cited by 114
Diamond surface engineering for molecular sensing with nitrogen—vacancy centers
Janitz, E., Herb, K., Vӧlker, L. A., Huxter, W. S., Degen, C. L., & Abendroth, J. M. (2022) · Journal of Materials Chemistry C · doi:10.1039/d2tc01258h · Cited by 140
Quantum‐Based Magnetic Field Sensors for Biosensing
Bao, B., Hua, Y., Wang, R., & Li, D. (2023) · Advanced Quantum Technologies · doi:10.1002/qute.202200146 · Cited by 108
Review—Quantum Biosensors: Principles and Applications in Medical Diagnostics
Das, S., Mazumdar, H., Khondakar, K. R., Mishra, Y. K., & Kaushik, A. K. (2024) · ECS Sensors Plus · doi:10.1149/2754-2726/ad47e2 · Cited by 89
Progression in Quantum Sensing/Bio-Sensing Technologies for Healthcare
Chugh, V., Basu, A., Kaushik, A. K., & Basu, A. K. (2023) · ECS Sensors Plus · doi:10.1149/2754-2726/acc190 · Cited by 81
“The spin method involves removing two neighboring carbon adjuncts from a diamond lattice and replacing either of those by a nitrogen atom.(51) This defect center is filled with an extra nitrogen electron, creating a structure known as a nitrogen-vacancy center (N–V center).”
MethodClinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Nanodiamond–Quantum Sensors Reveal Temperature Variation Associated to Hippocampal Neurons Firing
Petrini, G., Tomagra, G., Bernardi, E., Moreva, E. V., Traina, P., Marcantoni, A., Picollo, F., Kvaková, K., Cígler, P., Degiovanni, I. P., et al. (2022) · Advanced Science · doi:10.1002/advs.202202014 · Cited by 77
Self-citationXavier, J., Yu, D., Jones, C., Zossimova, E., & Vollmer, F. (2021) · Nanophotonics · doi:10.1515/nanoph-2020-0593 · Cited by 77
Nishimura, Y., Oshimi, K., Umehara, Y., Kumon, Y., Miyaji, K., Yukawa, H., Shikano, Y., Matsubara, T., Fujiwara, M., Baba, Y., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-83285-y · Cited by 55
Quantum enhanced non-interferometric quantitative phase imaging
Ortolano, G., Paniate, A., Boucher, P., Napoli, C., Soman, S., Pereira, S. F., Berchera, I. R., & Genovese, M. (2023) · Light Science & Applications · doi:10.1038/s41377-023-01215-1 · Cited by 60
“(6) and the fact that the quantum noise (shot noise) has a flat white spectrum σSN q ð Þ 1⁄4 σSN , indicate that the effect of shot noise is to generate artifacts especially at lower frequencies, which are not intrinsically suppressed by the phase retrieval algorithm.”
BackgroundSelf-citationNanoscale electric field imaging with an ambient scanning quantum sensor microscope
Qiu, Z., Hamo, A., Vool, U., Zhou, T. X., & Yacoby, A. (2022) · npj Quantum Information · doi:10.1038/s41534-022-00622-3 · Cited by 66
Fujiwara, M., Dohms, A., Suto, K., Nishimura, Y., Oshimi, K., Teki, Y., Cai, K., Benson, O. J., & Shikano, Y. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.043415 · Cited by 50
Sub-second temporal magnetic field microscopy using quantum defects in diamond
Parashar, M., Bathla, A., Shishir, D., Gokhale, A., Bandyopadhyay, S., & Saha, K. (2022) · Scientific Reports · doi:10.1038/s41598-022-12609-3 · Cited by 40
Neuronal growth on high-aspect-ratio diamond nanopillar arrays for biosensing applications
Losero, E., Jagannath, S., Pezzoli, M., Goblot, V., Babashah, H., Lashuel, H. A., Galland, C., & Quack, N. (2023) · Scientific Reports · doi:10.1038/s41598-023-32235-x · Cited by 38
“Diamond has been recognized as an ideal candidate material for novel biosensing platforms [20, 21, 22, 23, 24] as it is biocompatible [25] and features outstanding chemical and physical properties [26].”
BackgroundEvolution of quantum spin sensing: From bench-scale ODMR to compact integrations
Esmaeili, S., Schmalenberg, P. D., Wu, S., Zhou, Y., Rodrigues, S. P., Hussain, N., Kimura, T., Tadokoro, Y., Higashi, S., Banerjee, D., et al. (2024) · APL Materials · doi:10.1063/5.0193350 · Cited by 39
High-precision chemical quantum sensing in flowing monodisperse microdroplets
Sarkar, A., Jones, Z. R., Parashar, M., Druga, E., Akkiraju, A., Conti, S., Krishnamoorthi, P., Nachuri, S., Aman, P., Hashemi, M., et al. (2024) · Science Advances · doi:10.1126/sciadv.adp4033 · Cited by 29
“This has led to diverse applications, including in-cell thermometry [5–8] and reactive oxygen species detection [9,10], high-sensitivity lateral flow assays [11], and nuclear magnetic resonance (NMR) measurements in picoliter volumes [12,13], marking an exciting leap in precision measurement…”
All-Optical Wide-Field Selective Imaging of Fluorescent Nanodiamonds in Cells, In Vivo and Ex Vivo
Yanagi, T., Kaminaga, K., Suzuki, M., Abe, H., Yamamoto, H., Ohshima, T., Kuwahata, A., Sekino, M., Imaoka, T., Kakinuma, S., et al. (2021) · ACS Nano · doi:10.1021/acsnano.0c07740 · Cited by 26
Quantum-Enhanced Pattern Recognition
Ortolano, G., Napoli, C., Harney, C., Pirandola, S., Leonetti, G., Boucher, P., Losero, E., Genovese, M., & Berchera, I. R. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.20.024072 · Cited by 28
Self-citationStimulated Emission Depletion Spectroscopy of Color Centers in Hexagonal Boron Nitride
Malein, R. N. E., Khatri, P., Ramsay, A. J., & Luxmoore, I. J. (2021) · ACS Photonics · doi:10.1021/acsphotonics.0c01917 · Cited by 24
Chip‐Scale Optically Pumped Magnetometry Enabled by Tailorable Elliptical Dichroism Metasurface
Hu, J., Liang, Z., Zhou, P., Liu, L., Hu, G., & Ye, M. (2024) · Advanced Optical Materials · doi:10.1002/adom.202400594 · Cited by 23
Experimental quantum enhanced optical interferometry
Genovese, M. (2021) · AVS Quantum Science · doi:10.1116/5.0062114 · Cited by 26
Self-citationCorte, E., Sachero, S., Tchernij, S. D., Lühmann, T., Pezzagna, S., Traina, P., Degiovanni, I. P., Moreva, E. V., Olivero, P., Meijer, J., et al. (2021) · Advanced Photonics Research · doi:10.1002/adpr.202100148 · Cited by 19
“hypothesis that the SnV center is not fully formed under the adopted low-pressure hightemperature annealing process[5,6], or with the interpretation of the ZPL spectral diffusion as a consequence of the radiation-induced local strain interacting with the defects.”
BackgroundSelf-citationFluorine-based color centers in diamond
Tchernij, S. D., Lühmann, T., Corte, E., Sardi, F., Picollo, F., Traina, P., Brajković, M., Crnjac, A., Pezzagna, S., Pastuović, Ž., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-78436-6 · Cited by 17
Self-citationEmerging approaches for sensing and modulating neural activity enabled by nanocarbons and carbides
Driscoll, N., Dong, R., & Vitale, F. (2021) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2021.10.007 · Cited by 15
Bernardi, E., Moreva, E. V., Traina, P., Petrini, G., Tchernij, S. D., Forneris, J., Pastuović, Ž., Degiovanni, I. P., Olivero, P., & Genovese, M. (2020) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-020-00088-2 · Cited by 14
“Magnetometry in biological systems is of the utmost importance for fundamental biological science and medicine [1].”
BackgroundSelf-citationTchernij, S. D., Corte, E., Lühmann, T., Traina, P., Pezzagna, S., Degiovanni, I. P., Provatas, G., Moreva, E. V., Meijer, J., Olivero, P., et al. (2021) · New Journal of Physics · doi:10.1088/1367-2630/ac038a · Cited by 18
Self-citationThermometric Characterization of Fluorescent Nanodiamonds Suitable for Biomedical Applications
Pedroza-Montero, F. A., Santacruz‐Gómez, K., Acosta-Elías, M., Silva‐Campa, E., Meza‐Figueroa, D., Soto‐Puebla, D., Castaneda, B., Urrutia-Bañuelos, E., Álvarez-Bajo, O., Navarro-Espinoza, S., et al. (2021) · Applied Sciences · doi:10.3390/app11094065 · Cited by 12
“These optical properties make fluorescent nanodiamonds a suitable probe for bioimaging and thermic sensing applications in cellular environments [31,32].”
BackgroundZossimova, E., Jones, C., Perera, K. M. K., Pedireddy, S., Walter, M., & Vollmer, F. (2024) · Applied Physics Letters · doi:10.1063/5.0216468 · Cited by 12
Single photon sources for quantum radiometry: a brief review about the current state-of-the-art
Kück, S., López, M., Hofer, H., Georgieva, H., Christinck, J., Rodiek, B., Porrovecchio, G., Šmíd, M., Götzinger, S., Becher, C., et al. (2022) · Applied Physics B · doi:10.1007/s00340-021-07734-2 · Cited by 15
Self-citationEmerging Diamond Quantum Sensing in Bio-Membranes
Tan, Y., Hu, X., Hou, Y. X., & Chu, Z. (2022) · Membranes · doi:10.3390/membranes12100957 · Cited by 14
“Another aspect is that the measurement of weak magnetic fields associated with human neuron activity still requires further improvements in the case of a single AP [179].”
BackgroundStimulated Emission Depletion Microscopy with Color Centers in Hexagonal Boron Nitride
Khatri, P., Malein, R. N. E., Ramsay, A. J., & Luxmoore, I. J. (2021) · ACS Photonics · doi:10.1021/acsphotonics.1c00423 · Cited by 9
Sturari, S., Varzi, V., Aprà, P., Britel, A., Amine, N.-H., Andrini, G., Corte, E., Tomagra, G., Mino, L., Olivero, P., et al. (2023) · Surfaces and Interfaces · doi:10.1016/j.surfin.2023.102831 · Cited by 8
“These encompass tribology [6 – 8], catalysis [9 – 12], energy storage and conversion [13 – 15], photonics [16 – 18], quantum sensing [19 – 24] and biomedical applications [25 – 27].”
BackgroundSelf-citationThe new generation: quantum sensors
Gauglitz, G. (2021) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03554-7 · Cited by 8
“Evidence is given for a switch from conventional electrophysiological techniques to NV sensors, and for the possibility to measure neuronal signals [6].”
BackgroundGurjar, V., Rajan, A. K., Chaturvedi, A., Tiwari, R. R., Ratre, P., & Mishra, P. K. (2025) · Computational and Structural Biotechnology Reports · doi:10.1016/j.csbr.2025.100053 · Cited by 9
Quantum target ranging for LiDAR
Ortolano, G., & Berchera, I. R. (2025) · Physical Review Research · doi:10.1103/physrevresearch.7.l022059 · Cited by 8
Keshavarz, S. (., Inanlu, M. J., Omidfar, K., & Bazargan, V. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.114061 · Cited by 8
Recent Advances in Quantum Biosensing Technologies
Mpofu, K. T., & Mthunzi-Kufa, P. T. (2024) · Biomedical engineering · doi:10.5772/intechopen.1007858 · Cited by 12
Virzì, S., Meda, A., Redolfi, E., Gramegna, M., Brida, G., Genovese, M., & Degiovanni, I. P. (2024) · Applied Physics Letters · doi:10.1063/5.0226170 · Cited by 8
Self-citationAprà, P., Zanelli, G., Losero, E., Amine, N.-H., Andrini, G., Barozzi, M., Bernardi, E., Britel, A., Canteri, R., Degiovanni, I. P., et al. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c08780 · Cited by 5
Self-citationHigh-resolution quantum-enhanced phase imaging of cells
Paniate, A., Ortolano, G., Soman, S., Genovese, M., & Berchera, I. R. (2025) · Optica · doi:10.1364/optica.575944 · Cited by 6
Self-citationLin, M.-C., Lo, P., Nori, F., & Chen, H. (2022) · Journal of Physics Condensed Matter · doi:10.1088/1361-648x/ac9bbe · Cited by 4
Photon Statistics Modal Reconstruction by Detected and Undetected Light
Knoll, L. T., Petrini, G., Piacentini, F., Traina, P., Polyakov, S. V., Moreva, E. V., Degiovanni, I. P., & Genovese, M. (2023) · Advanced Quantum Technologies · doi:10.1002/qute.202300062 · Cited by 5
Self-citationAlduais, A. M. S., Alarifi, H. S., & Alfadda, H. A. (2024) · Diagnostics · doi:10.3390/diagnostics14141535 · Cited by 4
“The development of novel biosensors, such as those based on nitrogen-vacancy (NV) centers and fluorescent proteins, faces challenges in achieving the spatial resolution and sensitivity required to detect weak biological electromagnetic fields generated by neurons [33].”
BackgroundMonitoring cells local temperature variation using nitrogen-vacancy (NV) centers in nanodiamonds
Petrini, G., Tomagra, G., Bernardi, E., Moreva, E. V., Traina, P., Marcantoni, A., Picollo, F., Olivero, P., Kvaková, K., Cígler, P., et al. (2022) · IEEE International Workshop on Metrology for Industry 4.0 & IoT (MetroInd4.0&IoT) · doi:10.1109/metroind4.0iot54413.2022.9831763 · Cited by 3
Self-citationLimitations of Bulk Diamond Sensors for Single-Cell Thermometry
Alessio, A., Bernardi, E., Moreva, E. V., Degiovanni, I. P., Genovese, M., & Truccato, M. (2023) · Sensors · doi:10.3390/s24010200 · Cited by 3
“Nitrogen-Vacancy (NV) centers have been used in combination with Optically Detected Magnetic Resonance (ODMR); see [21,22] and the references therein.”
BackgroundMethodInfluentialSelf-citationWang, W., Tian, M., Xing, Y., Huang, P., Li, B., Wu, Z. W., & Liu, L. (2025) · Advanced Quantum Technologies · doi:10.1002/qute.202500112 · Cited by 4
Optimal control theory techniques for nitrogen vacancy ensembles in single crystal diamond
Liddy, M. S. Z., Borneman, T. W., Sprenger, P., & Cory, D. G. (2023) · Quantum Information Processing · doi:10.1007/s11128-023-04106-x · Cited by 2
Robotic Vectorial Field Alignment for Spin‐Based Quantum Sensors
Smith, J. A., Zhang, D., & Balram, K. C. (2023) · Advanced Science · doi:10.1002/advs.202304449 · Cited by 2
Sensing microscopic noise events by frequent quantum measurements
Virzì, S., Knoll, L. T., Avella, A., Piacentini, F., Gherardini, S., Gramegna, M., Kurizki, G., Kofman, A. G., Degiovanni, I. P., Genovese, M., et al. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.034014 · Cited by 2
Self-citationKühn, B., Picollo, F., Carabelli, V., & Rispoli, G. (2020) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-020-02472-4 · Cited by 3
“Therefore, it is mandatory in the future to develop probes that have a stiffness comparable with the brain tissue and that are at the same time brain tissue compatible with not trigger any inflammatory processes [76].”
BackgroundSelf-citationIntegration of Biosensors and Microfluidics and Their Application
Naghib, S. M., & Rezaeian, Y. (2025) · Series in bioengineering · doi:10.1007/978-3-031-88419-1_5 · Cited by 3
Optimal probe states for single-mode quantum target detection in arbitrary object reflectivity
Chen, W., & Tsai, P.-J. (2024) · Physical Review Research · doi:10.1103/physrevresearch.6.023084 · Cited by 1
“This implies weak interaction between the target and the probing light, a condition commonly encountered in measurements involving biological samples [37–41].”
BackgroundGerasimova, E. N., Yaroshenko, V. V., Talianov, P. M., Peltek, O. O., Mikhailova, L. V., Baranov, M. A., Kapitanova, P. V., Zuev, D. A., Timin, A. S., & Zyuzin, M. V. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2015/1/012045
“Simultaneous visualization and temperature measurements of synthesized capsules Temperature measurements inside living cells were realized using ODMR method under continuous wave (CW) microwave excitation [15].”
MethodStass, I., Wang, H., Cavalleri, M., & Hildebrandt, S. (2022) · Advanced Quantum Technologies · doi:10.1002/qute.202100154
Genovese, M., Olivero, P., & Piacentini, F. (2024) · International Journal of Quantum Information · doi:10.1142/s0219749924020027
Self-citationDiamond single photon source for metrology: focus on radiometry and imaging
Traina, P., Moreva, E. V., & Kück, S. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-13717-4.00011-6
Self-citationAll‐Optical Temperature Sensor Based on Nitrogen‐Vacancy Centers for Dissolution
Guo, J., Liu, X., Wang, Z., Zhang, N., & Liu, B. (2025) · Advanced Quantum Technologies · doi:10.1002/qute.202500215
Zanelli, G., Moreva, E. V., Bernardi, E., Losero, E., Tchernij, S. D., Forneris, J., Pastuović, Ž., Traina, P., Degiovanni, I. P., & Genovese, M. (2025) · Physical review. B./Physical review. B · doi:10.1103/3mlm-jjqq · Cited by 1
“The use of quantum states to sense physical observables, known as quantum sensing [1, 2], has demonstrated to be of factual advancement in a plethora of diverse applications (spanning from magnetometry, gravitational wave detection and quantum thermodynamics)[3–12].”
Self-citationEnhanced Temperature Sensing with Nitrogen-Vacancy Spin Ensembles in Diamond
Moreva, E. V., Bernardi, E., Zanelli, G., Traina, P., Pugliese, V., Pastuović, Ž., Degiovanni, I. P., & Genovese, M. (2026) · Journal of Physics Conference Series · doi:10.1088/1742-6596/3183/1/012008
Self-citationGenovese, M., D’Angelo, M., Olivero, P., & Piacentini, F. (2026) · International Journal of Quantum Information · doi:10.1142/s0219749926020016
Self-citationCamarneiro, F., Micaelo, Â., Costa, B. N. L., da Costa, L. M., Ghaeli, I., Paris, J. L., & Nieder, J. B. (2026) · Nanoscale · doi:10.1039/d6nr00839a
The evolving role of diamond materials in neuroscience and neuroengineering
Parker, L. M., Najafabadi, A. H., Kang, H., & Schirhagl, R. (2026) · Acta Biomaterialia · doi:10.1016/j.actbio.2026.10.054
Metadata
- Authors
- Petrini, G., Moreva, E., Bernardi, E., Traina, P., Tomagra, G., Carabelli, V., Degiovanni, I. P., & Genovese, M.
- Affiliations
- Istituto Nazionale di Ricerca Metrologica (IT)
- University of Turin (IT)
- Istituto Nazionale di Fisica Nucleare (IT)
- Corresponding author
- Moreva, Ekaterina
- Bernardi, Ettore
- Traina, Paolo
- ORCID
- Venue
- Advanced Quantum Technologies
- Publisher
- Wiley
- Published
- 2020-09-27
- Volume
- 3
- Issue
- 12
- ISSN
- 2511-9044 (ISSN-L)
- OpenAlex
- W3089084273
- Cited by
- 63
- References
- 185
- Citations by year
- 2026: 4 · 2025: 10 · 2024: 12 · 2023: 11 · 2022: 9 · 2021: 13 · 2020: 4
- FWCI
- 3.59
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Advanced Quantum Technologies (publishedVersion, cc-by)
- arXiv (Cornell University) (submittedVersion)
- CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion, cc-by)
- Institutional Research Information System University of Turin (University of Turin) (submittedVersion, cc-by)
- arXiv (Cornell University)
- Funders
- Horizon 2020 Framework Programme (828946, Horizon 2020)
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Diamond and Carbon-based Materials Research
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Mechanical and Optical Resonators
- Keywords
- nitrogen-vacancy centers, current sensing, temperature sensing, magnetic field measurement, neuronal activity detection, biocompatibility, spatial resolution, living cells
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.