On the 17 O correction for CO 2 mass spectrometric isotopic analysis
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
To calculate δ 13 C from raw CO 2 isotope data, the ion beam ratio of m/z 45 to 44 is corrected for the contribution arising from the contribution of 17 O‐bearing molecules. First, a review on the current state of 17 O‐corrections for CO 2 mass spectrometry is presented. The three correction algorithms that are generally in use, however, do produce biased δ 13 C values, and the bias is actually larger than the precision of modern isotope ratio mass spectrometers. The origin of this bias is twofold: different values for 17 R VPDB‐CO2 as well as different values for λ are used in the correction algorithms. Despite both values being of high importance, large discrepancies between the absolute values published for 17 R VPDB‐CO2 appear to be the main reason for the δ 13 C biases. Next, the question of how to choose the value of λ to best be used is considered. Natural (e.g. tropospheric) CO 2 as well as primary reference materials (PDB and NBS‐19), having been in isotope exchange with water, are assumed to lie on the fractionation line for waters. On this ground, λ = 0.5281 ± 0.0015, as determined for waters (Meijer and Li, Isot. Environ. Health Stud. , 1998; 34: 349–369), is suggested to be a base for the 17 O‐correction algorithm. Finally, an approach to determine the absolute value for 17 R VPDB‐CO2 , based on data of relative isotope measurements on two CO 2 gases having a large 17 O difference, is discussed and algebraic formulas are considered. Experimental data and new numerical values determined for 17 R VPDB‐CO2 and 17 R VSMOW are given in a companion paper. Copyright © 2003 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Referencing strategies and techniques in stable isotope ratio analysis
Werner, R. A., & Brand, W. A. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.258 · Cited by 1,033
Oxygen isotope fractionation in stratospheric CO2
Thiemens, M. H., Jackson, T., Mauersberger, K., Schueler, B., & Morton, J. (1991) · Geophysical Research Letters · doi:10.1029/91gl00121 · Cited by 113
Cited by
Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical Report)
Brand, W. A., Coplen, T. B., Vogl, J., Rosner, M., & Prohaska, T. (2014) · Pure and Applied Chemistry · doi:10.1515/pac-2013-1023 · Cited by 704
Brand, W. A., Assonov, S. S., & Coplen, T. B. (2010) · Pure and Applied Chemistry · doi:10.1351/pac-rep-09-01-05 · Cited by 385
Self-citationAbsolute isotopic abundance ratios and the accuracy of Δ47 measurements
Daëron, M., Blamart, D., Peral, M., & Affek, H. P. (2016) · Chemical Geology · doi:10.1016/j.chemgeo.2016.08.014 · Cited by 310
Guo, W., Mosenfelder, J. L., Goddard, W. A., & Eiler, J. M. (2009) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2009.05.071 · Cited by 262
John, C. M., & Bowen, D. (2016) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.7720 · Cited by 247
Metadata
- Authors
- Assonov, S. S., & Brenninkmeijer, C. A. M.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2003-04-08
- Volume
- 17
- Issue
- 10
- Pages
- 1007-1016
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2040401537
- Cited by
- 58
- References
- 2
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On the 17 O correction for CO 2 mass spectrometric isotopic analysis. https://app.cochat.ai/papers/10.1002/rcm.1012
- The paper
- Assonov, S. S., & Brenninkmeijer, C. A. M. (2003). On the 17 O correction for CO 2 mass spectrometric isotopic analysis. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.1012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.