CoChat

Sonic spray ionization applied to liquid chromatography/mass spectrometry analysis of endocrine‐disrupting chemicals in environmental water samples

Benijts, Tom, Günther, Wolfgang, Lambert, Willy, Leenheer, André De · 2003 · Rapid Communications in Mass Spectrometry
Cited by 35

The DOI matches its Crossref record.

Abstract

A sonic spray ionization liquid chromatography/mass spectrometry (LC/SSI‐MS) procedure combined with off‐line solid‐phase extraction was optimized for the analysis of 20 endocrine‐disrupting chemicals (EDCs) in water samples. Method development included a comparison of the novel sonic spray ionization (SSI) with more traditional ion sources, i.e. pneumatically assisted electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI). It was demonstrated that SSI and ESI spectra were very similar, but were more prone to the formation of solvent cluster ions as compared with APCI spectra. This phenomenon was most prominent for SSI and resulted in an increased chemical background in full‐scan mass spectra. However, this chemical noise did not affect the overall sensitivity of SSI and ESI. After optimization of LC and MS parameters, the LC/SSI‐MS method was validated. Recoveries ranged from 76.3 up to 113.4% for all compounds. Limits of detection (LOD) and quantitation (LOQ) were established between 3.0 and 11.5 ng/L and 9.9 and 38.0 ng/L, respectively. Within‐day (n = 5) and between‐day (n = 5) reproducibility were investigated at three levels and ranged from 3.3–16.5% and 7.6–19.2%, respectively. Eight‐point calibration curves were established and showed linearity for all compounds (r 2 > 0.987) over a linear dynamic range of 10–10 000 ng/L. Copyright © 2003 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.1131

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 35

Metadata

Authors
Benijts, T., Günther, W., Lambert, W., & Leenheer, A. D.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2003-07-15
Volume
17
Issue
16
Pages
1866-1872
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2120567537
Cited by
35
References
0
FWCI
1.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sonic spray ionization applied to liquid chromatography/mass spectrometry analysis of endocrine‐disrupting chemicals in environmental water samples. https://app.cochat.ai/papers/10.1002/rcm.1131
The paper
Benijts, T., Günther, W., Lambert, W., & Leenheer, A. D. (2003). Sonic spray ionization applied to liquid chromatography/mass spectrometry analysis of endocrine‐disrupting chemicals in environmental water samples. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.1131

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.