Sonic spray ionization applied to liquid chromatography/mass spectrometry analysis of endocrine‐disrupting chemicals in environmental water samples
The DOI matches its Crossref record.
Abstract
A sonic spray ionization liquid chromatography/mass spectrometry (LC/SSI‐MS) procedure combined with off‐line solid‐phase extraction was optimized for the analysis of 20 endocrine‐disrupting chemicals (EDCs) in water samples. Method development included a comparison of the novel sonic spray ionization (SSI) with more traditional ion sources, i.e. pneumatically assisted electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI). It was demonstrated that SSI and ESI spectra were very similar, but were more prone to the formation of solvent cluster ions as compared with APCI spectra. This phenomenon was most prominent for SSI and resulted in an increased chemical background in full‐scan mass spectra. However, this chemical noise did not affect the overall sensitivity of SSI and ESI. After optimization of LC and MS parameters, the LC/SSI‐MS method was validated. Recoveries ranged from 76.3 up to 113.4% for all compounds. Limits of detection (LOD) and quantitation (LOQ) were established between 3.0 and 11.5 ng/L and 9.9 and 38.0 ng/L, respectively. Within‐day (n = 5) and between‐day (n = 5) reproducibility were investigated at three levels and ranged from 3.3–16.5% and 7.6–19.2%, respectively. Eight‐point calibration curves were established and showed linearity for all compounds (r 2 > 0.987) over a linear dynamic range of 10–10 000 ng/L. Copyright © 2003 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Water Analysis: Emerging Contaminants and Current Issues
Richardson, S. D., & Ternes, T. A. (2014) · Analytical Chemistry · doi:10.1021/ac500508t · Cited by 2,144
A comprehensive urinary metabolomic approach for identifying kidney cancer
Kind, T., Tolstikov, V., Fiehn, O., & Weiss, R. H. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2007.01.028 · Cited by 449
Water Analysis: Emerging Contaminants and Current Issues
Richardson, S. D., & Ternes, T. A. (2005) · Analytical Chemistry · doi:10.1021/ac058022x · Cited by 363
Kumar, A., Kumar, A., Sharma, G., Naushad, M., Stadler, F. J., Ghfar, A. A., Dhiman, P., & Saini, R. V. (2017) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2017.07.117 · Cited by 274
Ocaña-González, J. A., Villar-Navarro, M., Ramos-Payán, M., Fernández-Torres, R., & Bello-López, M. A. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.07.002 · Cited by 129
Hou, F., Deng, X., Jiang, X., & Yu, J. (2014) · Journal of Chromatographic Science · doi:10.1093/chromsci/bmt175 · Cited by 16
Metadata
- Authors
- Benijts, T., Günther, W., Lambert, W., & Leenheer, A. D.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2003-07-15
- Volume
- 17
- Issue
- 16
- Pages
- 1866-1872
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2120567537
- Cited by
- 35
- References
- 0
- FWCI
- 1.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).