Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 192

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Targeted lipidomics using electron capture atmospheric pressure chemical ionization mass spectrometry

Lee, Seon Hwa, Williams, Michelle V., DuBois, Raymond N., Blair, Ian A. · 2003 · Rapid Communications in Mass Spectrometry

Abstract

There is an increasing need to be able to conduct quantitative lipidomics analyses as a complement to proteomics studies. The highest specificity for proteomics analysis can be obtained using methodology based on electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI) coupled with liquid chromatography/tandem mass spectrometry (LC/MS/MS). For lipidomics analysis it is often necessary to be able to separate enantiomers and regioisomers. This can be very challenging when using methodology based on conventional reversed‐phase chromatography. Normal‐phase chromatography using chiral columns can provide dramatic improvements in the resolution of enantiomers and regioisomers. However, conventional ESI‐ and APCI‐MS/MS has limited sensitivity, which makes it difficult to conduct studies in cell culture systems where only trace amounts of non‐esterified bioactive lipids are present. The use of electron capture APCI‐MS/MS overcomes this problem. Enantiomers and regioisomers of diverse bioactive lipids can be quantified using stable isotope dilution methodology coupled with normal‐phase chiral chromatography and electron capture APCI‐MS/MS. This methodology has allowed a lipidomics profile from rat epithelial cells maintained in culture to be delineated and allowed the effect of a non‐selective lipoxygenase inhibitor to be assessed. Copyright © 2003 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.1170

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 192

Metadata

Authors
Lee, S. H., Williams, M. V., DuBois, R. N., & Blair, I. A.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2003-08-21
Volume
17
Issue
19
Pages
2168-2176
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2151263304
Cited by
192
References
4
FWCI
5.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Targeted lipidomics using electron capture atmospheric pressure chemical ionization mass spectrometry. https://app.cochat.ai/papers/10.1002/rcm.1170
The paper
Lee, S. H., Williams, M. V., DuBois, R. N., & Blair, I. A. (2003). Targeted lipidomics using electron capture atmospheric pressure chemical ionization mass spectrometry. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.1170

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.