The DOI matches its Crossref record.
The determination of low d 5 ‐phenylalanine enrichment (0.002–0.09 atom percent excess), after conversion to phenylethylamine, in relation to protein turnover studies by gass chromatography/electron ionization mass spectrometry
Abstract
A gas chromatography/mass spectrometry (GC/MS) method for measuring very low levels of enrichment of d 5 ‐phenylalanine (0.002–0.09 atom percent excess) is described. This method makes it possible to determine the enrichment of amino acid incorporated into tissue protein during studies of protein synthesis in man. Phenylalamine is enzymatically converted to phenylethylamine and the d 5 ‐enrichment is measured in the heptafluorobutyryl derivative by selective‐ion recording under electron ionization conditions. The coefficients of variation for muscle‐protein hydrolysate samples enriched with d 5 ‐phenylalanine at the 0.005 and 0.05 atom percent excess levels were 6.0 and 1.2%, respectively. This precision at low enrichment and the small amount of contrast to the conventional approach which uses GC/MS for plasma amino acids (typically 2–20 atom percent excess) but gas isotope‐ratio mass spectrometry for protein‐bound amino acids, the enrichment of both plasmafree and protein‐bound d 5 ‐phenylalanine can be measured with a single instrument.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Katsanos, C. S., Kobayashi, H., Sheffield-Moore, M., Aarsland, A., & Wolfe, R. R. (2006) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00488.2005 · Cited by 923
Volpi, E., Kobayashi, H., Sheffield-Moore, M., Mittendorfer, B., & Wolfe, R. R. (2003) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/78.2.250 · Cited by 846
Dreyer, H. C., Fujita, S., Cadenas, J. G., Chinkes, D. L., Volpi, E., & Rasmussen, B. B. (2006) · The Journal of Physiology · doi:10.1113/jphysiol.2006.113175 · Cited by 570
Wilkinson, S. B., Tarnopolsky, M. A., MacDonald, M. J., MacDonald, J. R., Armstrong, D., & Phillips, S. M. (2007) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/85.4.1031 · Cited by 530
Fujita, S., Abe, T., Drummond, M. J., Cadenas, J. G., Dreyer, H. C., Sato, Y., Volpi, E., & Rasmussen, B. B. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00195.2007 · Cited by 496
Metadata
- Authors
- Calder, A. G., Anderson, S. E., Grant, I., McNurlan, M. A., & Garlick, P. J.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 1992-07
- Volume
- 6
- Issue
- 7
- Pages
- 421-424
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2166821055
- Cited by
- 164
- References
- 0
- FWCI
- 1.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The determination of low d 5 ‐phenylalanine enrichment (0.002–0.09 atom percent excess), after conversion to phenylethylamine, in relation to protein turnover studies by gass chromatography/electron ionization mass spectrometry. https://app.cochat.ai/papers/10.1002/rcm.1290060704
- The paper
- Calder, A. G., Anderson, S. E., Grant, I., McNurlan, M. A., & Garlick, P. J. (1992). The determination of low d 5 ‐phenylalanine enrichment (0.002–0.09 atom percent excess), after conversion to phenylethylamine, in relation to protein turnover studies by gass chromatography/electron ionization mass spectrometry. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.1290060704
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.