Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 266

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

A new concept for isotope ratio monitoring liquid chromatography/mass spectrometry

Krummen, Michael, Hilkert, Andreas W., Juchelka, Dieter, Duhr, Alexander, Schlüter, Hans‐Jürgen, Pesch, Reinhold·2004·Rapid Communications in Mass Spectrometry

Abstract

A new interface for the on‐line coupling of a liquid chromatograph to a stable isotope ratio mass spectrometer has been developed and tested. The interface is usable for 13 C/ 12 C determination of organic compounds, allowing measurement of small changes in 13 C abundance in individual analyte species. All of the carbon in each analyte is quantitatively converted into CO 2 while the analyte is still dissolved in the aqueous liquid phase. This is accomplished by an oxidizing agent such as ammonium peroxodisulfate. The CO 2 is separated from the liquid phase and transferred to the mass spectrometer. It is shown that the whole integrated process does not introduce isotope fractionation. The measured carbon isotope ratios are accurate and reproducible. The sensitivity of the complete system allows isotope ratio determination down to 400 ng of compound on‐column. By‐passing the high‐performance liquid chromatography (HPLC) separation allows bulk isotopic analysis with substantially lower sample amounts than those required by conventional elemental analyzers. The results of the first applications to amino acids, carbohydrates, and drugs, eluted from various types of HPLC columns, are presented. The wide range of chromatographic methods enables the analysis of compounds never before amenable to isotope ratio mass spectrometry techniques and may lead to the development of many new assays. Copyright © 2004 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.1620

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 266

Metadata

Authors
Krummen, M., Hilkert, A. W., Juchelka, D., Duhr, A., Schlüter, H., & Pesch, R.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2004-08-31
Volume
18
Issue
19
Pages
2260-2266
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2172264345
Cited by
266
References
8
FWCI
5.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A new concept for isotope ratio monitoring liquid chromatography/mass spectrometry. https://app.cochat.ai/papers/10.1002/rcm.1620
The paper
Krummen, M., Hilkert, A. W., Juchelka, D., Duhr, A., Schlüter, H., & Pesch, R. (2004). A new concept for isotope ratio monitoring liquid chromatography/mass spectrometry. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.1620

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.