The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
A new concept for isotope ratio monitoring liquid chromatography/mass spectrometry
Abstract
A new interface for the on‐line coupling of a liquid chromatograph to a stable isotope ratio mass spectrometer has been developed and tested. The interface is usable for 13 C/ 12 C determination of organic compounds, allowing measurement of small changes in 13 C abundance in individual analyte species. All of the carbon in each analyte is quantitatively converted into CO 2 while the analyte is still dissolved in the aqueous liquid phase. This is accomplished by an oxidizing agent such as ammonium peroxodisulfate. The CO 2 is separated from the liquid phase and transferred to the mass spectrometer. It is shown that the whole integrated process does not introduce isotope fractionation. The measured carbon isotope ratios are accurate and reproducible. The sensitivity of the complete system allows isotope ratio determination down to 400 ng of compound on‐column. By‐passing the high‐performance liquid chromatography (HPLC) separation allows bulk isotopic analysis with substantially lower sample amounts than those required by conventional elemental analyzers. The results of the first applications to amino acids, carbohydrates, and drugs, eluted from various types of HPLC columns, are presented. The wide range of chromatographic methods enables the analysis of compounds never before amenable to isotope ratio mass spectrometry techniques and may lead to the development of many new assays. Copyright © 2004 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hayes, J. M., Freeman, K. H., Popp, B. N., & Hoham, C. H. (1990) · Organic Geochemistry · doi:10.1016/0146-6380(90)90147-r · Cited by 832
Hilkert, A. W., Douthitt, C. B., Schlüter, H. J., & Brand, W. A. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990715)13:13<1226::aid-rcm575>3.0.co;2-9 · Cited by 308
Self-citationSt‐Jean, G. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.926 · Cited by 215
Compound-specific isotope analysis: extending toward and
Brand, W. A., Tegtmeyer, A. R., & Hilkert, A. W. (1994) · Organic Geochemistry · doi:10.1016/0146-6380(94)90004-3 · Cited by 124
Self-citationGas chromatography—stable isotope ratio analysis at natural abundance levels
Barrie, A., Bricout, J., & Koziet, J. (1984) · Journal of Mass Spectrometry · doi:10.1002/bms.1200111106 · Cited by 114
High-precision liquid chromatography-combustion isotope ratio mass spectrometry
Caimi, R. J., & Brenna, J. T. (1993) · Analytical Chemistry · doi:10.1021/ac00071a028 · Cited by 71
Hener, U., Brand, W. A., Hilkert, A. W., Juchelka, D., Mosandl, A., & Podebrad, F. (1998) · Zeitschrift für Lebensmittel-Untersuchung und -Forschung. B, Referate und Lebensmittelrecht · doi:10.1007/s002170050249 · Cited by 62
Self-citationOn-Line Determination of Oxygen Isotope Ratios of Water or Ice by Mass Spectrometry
Leuenberger, M., & Huber, C. (2002) · Analytical Chemistry · doi:10.1021/ac0203589 · Cited by 23
Cited by
Submicron structures provide preferential spots for carbon and nitrogen sequestration in soils
Vogel, C., Mueller, C. W., Höschen, C., Buegger, F., Heister, K., Schulz, S., Schloter, M., & Kögel-Knabner, I. (2014) · Nature Communications · doi:10.1038/ncomms3947 · Cited by 423
Elsner, M. (2010) · Journal of Environmental Monitoring · doi:10.1039/c0em00277a · Cited by 386
Isotope ratio mass spectrometry
Muccio, Z., & Jackson, G. P. (2009) · The Analyst · doi:10.1039/b808232d · Cited by 313
Elsner, M., Jochmann, M. A., Hofstetter, T. B., Hunkeler, D., Bernstein, A., Schmidt, T. C., & Schimmelmann, A. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5683-y · Cited by 276
Isotope‐ratio detection for gas chromatography
Sessions, A. L. (2006) · Journal of Separation Science · doi:10.1002/jssc.200600002 · Cited by 271
Metadata
- Authors
- Krummen, M., Hilkert, A. W., Juchelka, D., Duhr, A., Schlüter, H., & Pesch, R.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2004-08-31
- Volume
- 18
- Issue
- 19
- Pages
- 2260-2266
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2172264345
- Cited by
- 266
- References
- 8
- FWCI
- 5.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new concept for isotope ratio monitoring liquid chromatography/mass spectrometry. https://app.cochat.ai/papers/10.1002/rcm.1620
- The paper
- Krummen, M., Hilkert, A. W., Juchelka, D., Duhr, A., Schlüter, H., & Pesch, R. (2004). A new concept for isotope ratio monitoring liquid chromatography/mass spectrometry. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.1620
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.