A liquid‐phase microextraction method, combining a dual gauge microsyringe with a hollow fiber membrane, for the determination of organochlorine pesticides in aqueous solution by gas chromatography/ion trap mass spectrometry
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A liquid‐phase microextraction (LPME) method has been demonstrated for the extraction and determination of organochlorine pesticides (OCPs) in aqueous solution. The method combines a dual gauge microsyringe with a hollow fiber membrane (LPME/DGM‐HF) followed by detection by gas chromatography/ion trap mass spectrometry (GC/ITMS). The advantages include speed, low solvent and sample consumption, simplicity and ease of use. The extraction time, solvent selection, salt concentration and sample stirring rate have been investigated in order to optimize extraction efficiency. The viability is evaluated by measuring the linearity and detection limit of the five OCPs in aqueous solution. Detection linearity for the OCPs has been achieved over a range of concentrations between 1 and 500 μg/L (r 2 > 0.930), with a detection limit of 0.1 μg/L for each OCP. Copyright © 2004 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prosen, H., & Zupančič-Kralj, L. (1999) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(98)00109-5 · Cited by 565
Cited by
Pedersen-Bjergaard, S., & Rasmussen, K. E. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.08.088 · Cited by 486
Lee, J., Lee, H. K., Rasmussen, K. E., & Pedersen-Bjergaard, S. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.06.050 · Cited by 398
Jouyban, A., Farajzadeh, M. A., & Afshar Mogaddam, M. R. (2020) · Talanta · doi:10.1016/j.talanta.2019.120169 · Cited by 122
Cortada, C., Vidal, L., Pastor, R., Santiago, N., & Canals, A. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.07.041 · Cited by 112
New passive sampling device for effective monitoring of pesticides in water
Valenzuela, E. F., Menezes, H. C., & Cardeal, Z. L. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.12.017 · Cited by 48
Metadata
- Authors
- Yan, C., & Wu, H.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2004-11-09
- Volume
- 18
- Issue
- 24
- Pages
- 3015-3018
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2131840634
- Cited by
- 48
- References
- 1
- FWCI
- 3.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A liquid‐phase microextraction method, combining a dual gauge microsyringe with a hollow fiber membrane, for the determination of organochlorine pesticides in aqueous solution by gas chromatography/ion trap mass spectrometry. https://app.cochat.ai/papers/10.1002/rcm.1722
- The paper
- Yan, C., & Wu, H. (2004). A liquid‐phase microextraction method, combining a dual gauge microsyringe with a hollow fiber membrane, for the determination of organochlorine pesticides in aqueous solution by gas chromatography/ion trap mass spectrometry. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.1722
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.