The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
High precision measurements of 17 O/ 16 O and 18 O/ 16 O ratios in H 2 O
Abstract
We have optimized the method of water fluorination using the solid reagent CoF 3 to produce O 2 . This allows isotope ratio measurements by dual‐inlet mass spectrometry with very high precision of 0.01 to 0.03‰ for both δ 17 O and δ 18 O. Using this method, δ 17 O and δ 18 O of atmospheric O 2 were determined as 12.08 and 23.88‰ vs. VSMOW, respectively. Likewise, δ 17 O and δ 18 O of GISP were −13.12 and −24.73‰, and for SLAP they were −29.48 and −55.11‰ vs. VSMOW, respectively. Analysis of these data in a ln( δ 17 O + 1) vs. ln( δ 18 O + 1) plot yields a line with a regression coefficient ( λ ) of 0.5279 ± 0.0001 (R 2 = 0.999999). We also determined the fractionation factors 17 α and 18 α in liquid‐vapor equilibrium, and found that the ratio ln 17 α /ln 18 α is constant (0.529 ± 0.001) over the temperature range 11.4 to 41.5°C. Copyright © 2005 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Horita, J., & Wesolowski, D. J. (1994) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(94)90096-5 · Cited by 940
Cited by
Brand, W. A., Assonov, S. S., & Coplen, T. B. (2010) · Pure and Applied Chemistry · doi:10.1351/pac-rep-09-01-05 · Cited by 385
Absolute isotopic abundance ratios and the accuracy of Δ47 measurements
Daëron, M., Blamart, D., Peral, M., & Affek, H. P. (2016) · Chemical Geology · doi:10.1016/j.chemgeo.2016.08.014 · Cited by 310
Guo, W., Mosenfelder, J. L., Goddard, W. A., & Eiler, J. M. (2009) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2009.05.071 · Cited by 262
John, C. M., & Bowen, D. (2016) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.7720 · Cited by 247
Atomic weights of the elements 2007 (IUPAC Technical Report)
Wieser, M. E., & Berglund, M. (2009) · Pure and Applied Chemistry · doi:10.1351/pac-rep-09-08-03 · Cited by 220
Metadata
- Authors
- Barkan, E., & Luz, B.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2005-11-24
- Volume
- 19
- Issue
- 24
- Pages
- 3737-3742
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W3184258599
- Cited by
- 492
- References
- 1
- FWCI
- 9.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High precision measurements of 17 O/ 16 O and 18 O/ 16 O ratios in H 2 O. https://app.cochat.ai/papers/10.1002/rcm.2250
- The paper
- Barkan, E., & Luz, B. (2005). High precision measurements of 17 O/ 16 O and 18 O/ 16 O ratios in H 2 O. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.2250
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.