The DOI matches its Crossref record.
Matrix‐assisted laser desorption/ionization imaging mass spectrometry for direct measurement of clozapine in rat brain tissue
Abstract
Matrix‐assisted laser desorption/ionization hyphenated with quadrupole time‐of‐flight (QTOF) mass spectrometry (MS) has been used to directly determine the distribution of pharmaceuticals in rat brain tissue slices which might unravel their disposition for new drug development. Clozapine, an antipsychotic drug, and norclozapine were used as model compounds to investigate fundamental parameters such as matrix and solvent effects and irradiance dependence on MALDI intensity but also to address the issues with direct tissue imaging MS technique such as (1) uniform coating by the matrix, (2) linearity of MALDI signals, and (3) redistribution of surface analytes. The tissue sections were coated with various matrices on MALDI plates by airspray deposition prior to MS detection. MALDI signals of analytes were detected by monitoring the dissociation of the individual protonated molecules to their predominant MS/MS product ions. The matrices were chosen for tissue applications based on their ability to form a homogeneous coating of dense crystals and to yield greater sensitivity. Images revealing the spatial localization in tissue sections using MALDI‐QTOF following a direct infusion of 3 H‐clozapine into rat brain were found to be in good correlation with those using a radioautographic approach. The density of clozapine and its major metabolites from whole brain homogenates was further confirmed using fast high‐performance liquid chromatography/tandem mass spectrometry (HPLC‐MS/MS) procedures. Copyright © 2006 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
MALDI imaging mass spectrometry: molecular snapshots of biochemical systems
Cornett, D. S., Reyzer, M. L., Chaurand, P., & Caprioli, R. M. (2007) · Nature Methods · doi:10.1038/nmeth1094 · Cited by 886
Norris, J. L., & Caprioli, R. M. (2013) · Chemical Reviews · doi:10.1021/cr3004295 · Cited by 696
Mass spectrometry imaging for drug distribution studies
Prideaux, B., & Stoeckli, M. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.07.028 · Cited by 279
MALDI imaging mass spectrometry: Spatial molecular analysis to enable a new age of discovery
Gessel, M. M., Norris, J. L., & Caprioli, R. M. (2014) · Journal of Proteomics · doi:10.1016/j.jprot.2014.03.021 · Cited by 276
Ifa, D. R., Wiseman, J. M., Song, Q., & Cooks, R. G. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.08.003 · Cited by 261
Metadata
- Authors
- Hsieh, Y., Casale, R., Fukuda, E., Chen, J., Knemeyer, I., Wingate, J., Morrison, R., & Korfmacher, W.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2006-02-09
- Volume
- 20
- Issue
- 6
- Pages
- 965-972
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2158257117
- Cited by
- 187
- References
- 0
- FWCI
- 8.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Matrix‐assisted laser desorption/ionization imaging mass spectrometry for direct measurement of clozapine in rat brain tissue. https://app.cochat.ai/papers/10.1002/rcm.2397
- The paper
- Hsieh, Y., Casale, R., Fukuda, E., Chen, J., Knemeyer, I., Wingate, J., Morrison, R., & Korfmacher, W. (2006). Matrix‐assisted laser desorption/ionization imaging mass spectrometry for direct measurement of clozapine in rat brain tissue. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.2397
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.