CoChat

Improved method for isotopic and quantitative analysis of dissolved inorganic carbon in natural water samples

Assayag, Nelly, Rivé, Karine, Ader, Magali, Jézéquel, Didier, Agrinier, Pierre · 2006 · Rapid Communications in Mass Spectrometry
Cited by 151

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

We present here an improved and reliable method for measuring the concentration of dissolved inorganic carbon (DIC) and its isotope composition ( δ 13 C DIC ) in natural water samples. Our apparatus, a gas chromatograph coupled to an isotope ratio mass spectrometer (GCIRMS), runs in a quasi‐automated mode and is able to analyze about 50 water samples per day. The whole procedure (sample preparation, CO 2(g) –CO 2(aq) equilibration time and GCIRMS analysis) requires 2 days. It consists of injecting an aliquot of water into a H 3 PO 4 ‐loaded and He‐flushed 12 mL glass tube. The H 3 PO 4 reacts with the water and converts the DIC into aqueous and gaseous CO 2 . After a CO 2(g) –CO 2(aq) equilibration time of between 15 and 24 h, a portion of the headspace gas (mainly CO 2 +He) is introduced into the GCIRMS, to measure the carbon isotope ratio of the released CO 2(g) , from which the δ 13 C DIC is determined via a calibration procedure. For standard solutions with DIC concentrations ranging from 1 to 25 mmol · L −1 and solution volume of 1 mL (high DIC concentration samples) or 5 mL (low DIC concentration samples), δ 13 C DIC values are determined with a precision (1 σ ) better than 0.1‰. Compared with previously published headspace equilibration methods, the major improvement presented here is the development of a calibration procedure which takes the carbon isotope fractionation associated with the CO 2(g) –CO 2(aq) partition into account: the set of standard solutions and samples has to be prepared and analyzed with the same ‘gas/liquid’ and ‘H 3 PO 4 /water’ volume ratios. A set of natural water samples (lake, river and hydrothermal springs) was analyzed to demonstrate the utility of this new method. Copyright © 2006 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.2585

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Assayag, N., Rivé, K., Ader, M., Jézéquel, D., & Agrinier, P.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2006-06-30
Volume
20
Issue
15
Pages
2243-2251
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W1972897229
Cited by
151
References
3
FWCI
4.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.