Resolving stoichiometries and oligomeric states of glutamate synthase protein complexes with curve fitting and simulation of electrospray mass spectra
The DOI matches its Crossref record.
Abstract
A complicating factor in analyzing electrospray ionization mass spectra of intact macromolecular heterogeneous protein complexes is the potential overlap of ions from different species present in solution. Therefore, it is often not possible to assign all ion signals. With the aim of allowing the more efficient and comprehensive analysis of very complex mass spectra of intact heterogeneous protein complexes we developed a software program: SOMMS. The program uses simple user input parameters together with Gaussian curve fitting to simulate putative mass spectra of protein (sub)complexes within a specified charge state window. In addition, the program can simulate spectra for heterogeneous protein complexes using bi‐ and multinomial distributions and it can calculate zero‐charge spectra and relatively quantify the abundance of each component in a mixture. As a proof of concept we analyzed the complex mass spectra of α ‐glutamate synthase and α β ‐glutamate synthase from Azosprillum brasilense . Using our program we could determine that α ‐glutamate synthase is in equilibrium between its dimeric, tetrameric, hexameric and dodecameric conformation, whereas α β ‐glutamate synthase forms up to 15 different heterooligomeric assemblies composed of α ‐ and β ‐subunits. Thus, SOMMS allows resolving stoichiometries and oligomeric states of protein complexes even from very complicated mass spectra. These complexes could not be assigned by using maximum entropy calculations. We compared our mass spectrometry data on glutamate synthases with available X‐ray, small‐angle X‐ray scattering and size‐exclusion chromatography data. Copyright © 2006 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Marty, M. T., Baldwin, A. J., Marklund, E. G., Hochberg, G. K. A., Benesch, J. L. P., & Robinson, C. V. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00140 · Cited by 1,000
Determining the stoichiometry and interactions of macromolecular assemblies from mass spectrometry
Hernández, H., & Robinson, C. V. (2007) · Nature Protocols · doi:10.1038/nprot.2007.73 · Cited by 655
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Self-citationIon mobility mass spectrometry of proteins and proteinassemblies
Uetrecht, C., Rose, R. J., van Duijn, E., Lorenzen, K., & Heck, A. J. R. (2010) · Chem. Soc. Rev. · doi:10.1039/b914002f · Cited by 462
Self-citationThe Role of Mass Spectrometry in Structure Elucidation of Dynamic Protein Complexes
Sharon, M., & Robinson, C. V. (2007) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.76.061005.090816 · Cited by 357
Metadata
- Authors
- van Breukelen, B., Barendregt, A., Heck, A. J. R., & van den Heuvel, R. H. H.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2006-07-24
- Volume
- 20
- Issue
- 16
- Pages
- 2490-2496
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2091607666
- Cited by
- 51
- References
- 0
- FWCI
- 1.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Resolving stoichiometries and oligomeric states of glutamate synthase protein complexes with curve fitting and simulation of electrospray mass spectra. https://app.cochat.ai/papers/10.1002/rcm.2620
- The paper
- van Breukelen, B., Barendregt, A., Heck, A. J. R., & van den Heuvel, R. H. H. (2006). Resolving stoichiometries and oligomeric states of glutamate synthase protein complexes with curve fitting and simulation of electrospray mass spectra. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.2620
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.