Method to determine 4‐oxo‐retinoic acids, retinoic acids and retinol in serum and cell extracts by liquid chromatography/diode‐array detection atmospheric pressure chemical ionisation tandem mass spectrometry
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Retinoic acid isomers, 4‐oxo‐retinoic acid isomers and retinol are present in the serum of mammals. In this study a high‐performance liquid chromatography (HPLC) separation, sample preparation and tandem mass spectrometry (MS/MS) method was established for quick and easy sample preparation and sensitive determination of retinoids such as all‐ trans ‐4‐oxo‐retinoic acid, 13‐ cis ‐4‐oxo‐retinoic acid, 13‐ cis ‐retinoic acid, 9‐ cis ‐retinoic acid, all‐ trans ‐retinoic acid and retinol in serum and cell extracts. Serum samples were simply treated with three times the volume of isopropanol, dried under vacuum, taken up in the HPLC solvent and immediately put into the autosampler for an automated single‐run HPLC analysis. With this MS/MS method we were able to detect 7 pg and quantify 20 pg of all‐ trans ‐retinoic acid, 4‐oxo‐all‐ trans ‐retinoic acid and retinol directly on‐column and were able to determine a concentration as low as 0.2 ng/mL in ethanolic standards and in biological samples. This method allows ultra‐sensitive detection, excellent selectivity and a very simple sample preparation to determine retinoic acids, 4‐oxo‐retinoic acids and retinol in serum and cell extracts for the study of endogenous retinoids. Copyright © 2006 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Duester, G. (2000) · European Journal of Biochemistry · doi:10.1046/j.1432-1327.2000.01497.x · Cited by 570
Retinoid-binding proteins: mediators of retinoid action
NOY, N. (2000) · Biochemical Journal · doi:10.1042/bj3480481 · Cited by 422
Cited by
Quantitative Profiling of Endogenous Retinoic Acid in Vivo and in Vitro by Tandem Mass Spectrometry
Kane, M. A., Folias, A. E., Wang, C., & Napoli, J. L. (2008) · Analytical Chemistry · doi:10.1021/ac702030f · Cited by 230
Bohn, T., Desmarchelier, C., El, S. N., Keijer, J., van Schothorst, E., Rühl, R., & Borel, P. (2019) · Proceedings of the Nutrition Society · doi:10.1017/s0029665118002641 · Cited by 156
Self-citationArnold, S. L. M., Amory, J. K., Walsh, T. J., & Isoherranen, N. (2012) · Journal of Lipid Research · doi:10.1194/jlr.d019745 · Cited by 119
Metadata
- Authors
- Rühl, R.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2006-07-24
- Volume
- 20
- Issue
- 16
- Pages
- 2497-2504
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2136643063
- Cited by
- 74
- References
- 2
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Method to determine 4‐oxo‐retinoic acids, retinoic acids and retinol in serum and cell extracts by liquid chromatography/diode‐array detection atmospheric pressure chemical ionisation tandem mass spectrometry. https://app.cochat.ai/papers/10.1002/rcm.2621
- The paper
- Rühl, R. (2006). Method to determine 4‐oxo‐retinoic acids, retinoic acids and retinol in serum and cell extracts by liquid chromatography/diode‐array detection atmospheric pressure chemical ionisation tandem mass spectrometry. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.2621
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.