Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 163

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

After two decades a second anchor for the VPDB δ 13 C scale

Coplen, Tyler B., Brand, Willi A., Gehre, Matthias, Gröning, Manfred, Meijer, Harro A. J., Toman, Blaza, Verkouteren, R. Michael·2006·Rapid Communications in Mass Spectrometry

Abstract

In 1985, the primary recommendation of a Consultants' Group Meeting of the International Atomic Energy Agency (IAEA)1 was that a new (Vienna Peedee Belemnite) VPDB δ13C scale be established with NBS 19 carbonate assigned to be +1.95‰ as its single anchor. This recommendation improved δ13C measurement uncertainties,2 especially those of materials with δ13C values near 0‰. A fundamental problem remained that materials with δ13C values far from 0‰, such as NBS 22 oil, had much poorer uncertainties.2, 3 Recognizing that two-point calibrations of the δ2H and δ18O scales substantially improved the agreement among laboratories,4 the IAEA convened a panel in 2004 to review stable carbon isotopic reference materials and to recommend a second reference material for two-point normalization of the δ13C scale. Four laboratories (Centrum voor Isotopen Onderzoek, Groningen, The Netherlands; Max-Planck-Institute for Biogeochemistry, Jena, Germany; UFZ Leipzig-Halle, Leipzig, Germany; US Geological Survey, Reston, VA, USA) performed analytical measurements. Participants at the US National Institute of Science and Technology (NIST) headed the task to estimate consensus means and uncertainties using multivariate Bayesian techniques. Collectively, the laboratories performed 1055 state-of-the-art continuous-flow elemental-analyzer mass spectrometry measurements using the general method of Qi et al.5 on selected organic and inorganic carbon isotopic reference materials. Aims of the work included determining consensus δ13C values of stable carbon isotopic reference materials and confirming that isotopic materials measured in this study are isotopically homogeneous in amounts used in continuous-flow methods [m(C) of approximately ∼40 µg]. Based on high precision mass spectrometric measurements,6, 7 a consensus value of −46.6‰ was assigned to L-SVEC lithium carbonate.8 The results (Table 1) were provided to the International Union of Pure and Applied Chemistry (IUPAC).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.2727

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 163

Metadata

Authors
Coplen, T. B., Brand, W. A., Gehre, M., Gröning, M., Meijer, H. A. J., Toman, B., & Verkouteren, R. M.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2006-10-02
Volume
20
Issue
21
Pages
3165-3166
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2020243600
Cited by
163
References
1
FWCI
8.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: After two decades a second anchor for the VPDB δ 13 C scale. https://app.cochat.ai/papers/10.1002/rcm.2727
The paper
Coplen, T. B., Brand, W. A., Gehre, M., Gröning, M., Meijer, H. A. J., Toman, B., & Verkouteren, R. M. (2006). After two decades a second anchor for the VPDB δ 13 C scale. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.2727

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.