Analysis of testosterone and dihydrotestosterone from biological fluids as the oxime derivatives using high‐performance liquid chromatography/tandem mass spectrometry
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A sensitive liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) method for the simultaneous quantitative analysis of dihydrotestosterone (DHT) and testosterone (T) from biological fluids has been developed. Commercially available deuterated analogues were used as internal standards. Steroids were extracted from serum or testicular fluid with hexane/ethyl acetate, evaporated to dryness, and treated with hydroxylamine to form their oxime derivatives. Upon chromatographic separation, the compounds were quantified using selected reaction monitoring (SRM). For T, the [M+H] + ion at m/z 304 and the fragment ion at m/z 124 were used as the precursor and product ions. For DHT the ion cluster [M+H+ACN] + at m/z 347 and the dissociated ion [M+H] + at m/z 306 were used as the precursor and product ions, respectively. The limits of detectability on‐column were in the sub‐femtomole range for both compounds and the intra‐day coefficient of variation (CV) for analysis from serum was less than 7% for both compounds. Given its high reproducibility, sensitivity, and relative simplicity, this assay should be of use in determining androgen levels in biospecimens, particularly in settings where sample quantity or steroid concentration are low. Copyright © 2007 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Androgen Axis in Recurrent Prostate Cancer
Mohler, J. L., Gregory, C. W., Ford, O. H., Kim, D., Weaver, C. M., Petrusz, P., Wilson, E. M., & French, F. S. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-1146-03 · Cited by 675
Performance Characteristics of a Novel Tandem Mass Spectrometry Assay For Serum Testosterone
Kushnir, M. M., Rockwood, A. L., Roberts, W. L., Pattison, E. G., Bunker, A. M., Fitzgerald, R. L., & Meikle, A. W. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.052167 · Cited by 170
Liu, S., Sjövall, J., & Griffiths, W. J. (2003) · Analytical Chemistry · doi:10.1021/ac0346297 · Cited by 141
Cited by
Nguyen, H. M., Vessella, R. L., Morrissey, C., Brown, L. G., Coleman, I. M., Higano, C. S., Mostaghel, E. A., Zhang, X., True, L. D., Lam, H.-M., et al. (2017) · The Prostate · doi:10.1002/pros.23313 · Cited by 300
Self-citationHarwood, D. T., & Handelsman, D. J. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.09.003 · Cited by 243
Leon, C. G., Locke, J. A., Adomat, H. H., Etinger, S. L., Twiddy, A. L., Neumann, R. D., Nelson, C. C., Guns, E. S., & Wasan, K. M. (2010) · The Prostate · doi:10.1002/pros.21072 · Cited by 168
Carvalho, V. M. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.08.027 · Cited by 90
An intracrine view of sex steroids, immunity, and metabolic regulation
Rubinow, K. B. (2018) · Molecular Metabolism · doi:10.1016/j.molmet.2018.03.001 · Cited by 82
“After a period of prolonged quiescence, this area of investigation is reemerging in a new era in which mass spectrometric approaches are available for quantification of low abundance steroids and kinetic modeling of steroidogenic enzyme activity, finally offering the methodologic means of reinvigorating this field of…”
BackgroundJoyce, K. E., Biggs, M. L., Djoussé, L., Ix, J. H., Kizer, J. R., Siscovick, D. S., Shores, M. M., Matsumoto, A. M., & Mukamal, K. J. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2016-2623 · Cited by 40
Metadata
- Authors
- Kalhorn, T. F., Page, S. T., Howald, W. N., Mostaghel, E. A., & Nelson, P. S.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2007-09-03
- Volume
- 21
- Issue
- 19
- Pages
- 3200-3206
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2146902911
- Cited by
- 96
- References
- 3
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.