CoChat

The inclusion of succinylacetone as marker for tyrosinemia type I in expanded newborn screening programs

la Marca, Giancarlo, Malvagia, Sabrina, Pasquini, Elisabetta, Innocenti, Marzia, Fernandez, Maira Rebollido, Donati, Maria Alice, Zammarchi, Enrico · 2008 · Rapid Communications in Mass Spectrometry
Cited by 70

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

In expanded newborn screening programs by liquid chromatography/tandem mass spectrometry false negatives for tyrosinemia type I are a significant problem. We describe a method for inclusion of succinylacetone in order to avoid false negatives. We studied spots from 13 000 neonates born in Tuscany (January–May 2007) and ten spots from six patients with tyrosinemia type I. The traditional screening method was modified by adding dioxooctanoid acid (or 13 C 2 ‐succinylacetone) as an internal standard to the methanolic solution of deuterated acylcarnitines and amino acids. A hydrazine solution was added to the mixture. The times of extraction, butylation and drying were only slightly prolonged. Specific multiple reaction monitoring for derivatized and labelled succinylacetone and dioxooctanoic acid was carried out. The assays were linear up to 100 µmol/L for succinylacetone. Intra‐ and inter‐day imprecision data were in the range of 1.34% to 7.09% and 3.50% to 4.49%. Limits of detection and of quantification were 0.2 µmol/L and 0.4 µmol/L, respectively. Recovery ranged from 97.02% to 100.29%. Succinylacetone levels in samples from unaffected neonates were very close to the detection limit. Of the 46 recalls, eight (17.4%) were for abnormal tyrosine levels and all these cases had succinylacetone levels within the normal range (<2.4 µmol/L). In ten spots from six affected patients succinylacetone values ranged from 3.3 to 35.0 µmol/L. Including succinylacetone in newborn screening programs for amino acids and acylcarnitines avoids false‐negative results for tyrosinemia type I. Newborn screening laboratories should consider implementing these modifications. Copyright © 2008 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.3428

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
la Marca, G., Malvagia, S., Pasquini, E., Innocenti, M., Fernandez, M. R., Donati, M. A., & Zammarchi, E.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2008-02-21
Volume
22
Issue
6
Pages
812-818
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2052751346
Cited by
70
References
1
FWCI
4.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.