The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Determination of 13 C/ 12 C ratios of endogenous urinary steroids: method validation, reference population and application to doping control purposes
Abstract
The application of a comprehensive gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS)‐based method for stable carbon isotopes of endogenous urinary steroids is presented. The key element in sample preparation is the consecutive cleanup with high‐performance liquid chromatography (HPLC) of underivatized and acetylated steroids, which allows the isolation of ten analytes (11 β ‐hydroxyandrosterone, 5 α ‐androst‐16‐en‐3 β ‐ol, pregnanediol, androsterone, etiocholanolone, testosterone, epitestosterone, 5 α ‐androstane‐3 α ,17 β ‐diol, 5 β ‐androstane‐3 α ,17 β ‐diol and dehydroepiandrosterone) from a single urine specimen. These steroids are of particular importance to doping controls as they enable the sensitive and retrospective detection of steroid abuse by athletes. Depending on the biological background, the determination limit for all steroids ranges from 5 to 10 ng/mL for a 10 mL specimen. The method is validated by means of linear mixing models for each steroid, which covers repeatability and reproducibility. Specificity was further demonstrated by gas chromatography/mass spectrometry (GC/MS) for each analyte, and no influence of the sample preparation or the quantity of analyte on carbon isotope ratios was observed. In order to determine naturally occurring 13 C/ 12 C ratios of all implemented steroids, a reference population of n = 61 subjects was measured to enable the calculation of reference limits for all relevant steroidal Δ values. Copyright © 2008 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Craig, H. (1957) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(57)90024-8 · Cited by 4,170
Cited by
Chiral Toxicology: It's the Same Thing…Only Different
Smith, S. W. (2009) · Toxicological Sciences · doi:10.1093/toxsci/kfp097 · Cited by 602
Piper, T., Schänzer, W., & Thevis, M. (2016) · Drug Testing and Analysis · doi:10.1002/dta.2095 · Cited by 38
Self-citationPiper, T., Riemann, P., Opfermann, G., Mareck, U., Geyer, H., Vajiala, G., Flenker, U., & Schänzer, W. (2009) · Drug Testing and Analysis · doi:10.1002/dta.53 · Cited by 31
Self-citationMareck, U., Geyer, H., Fußhöller, G., Schwenke, A., Haenelt, N., Piper, T., Thevis, M., & Schänzer, W. (2010) · Drug Testing and Analysis · doi:10.1002/dta.234 · Cited by 28
Self-citationPiper, T., Dib, J., Putz, M., Fusshöller, G., Pop, V., Lagojda, A., Kuehne, D., Geyer, H., Schänzer, W., & Thevis, M. (2018) · Drug Testing and Analysis · doi:10.1002/dta.2527 · Cited by 23
Self-citationInvestigations into the human metabolism of ecdysterone.
Piper, T., & Thevis, M. (2023) · Drug Testing and Analysis · doi:10.1002/dta.3582 · Cited by 6
Self-citation
Metadata
- Authors
- Piper, T., Mareck, U., Geyer, H., Flenker, U., Thevis, M., Platen, P., & Schänzer, W.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2008-06-06
- Volume
- 22
- Issue
- 14
- Pages
- 2161-2175
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2112628426
- Cited by
- 169
- References
- 1
- FWCI
- 51.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.