The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Differential stable isotope labeling of peptides for quantitation and de novo sequence derivation
Abstract
We have demonstrated the use of per‐methyl esterification of peptides for relative quantification of proteins between two mixtures of proteins and automated de novo sequence derivation on the same dataset. Protein mixtures for comparison were digested to peptides and resultant peptides methylated using either d0‐ or d3‐methanol. Methyl esterification of peptides converted carboxylic acids, such as are present on the side chains of aspartic and glutamic acid as well as the carboxyl terminus, to their corresponding methyl esters. The separate d0‐ and d3‐methylated peptide mixtures were combined and the mixture subjected to microcapillary high performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS). Parent proteins of methylated peptides were identified by correlative database searching of peptide tandem mass spectra. Ratios of proteins in the two original mixtures could be calculated by normalization of the area under the curve for identical charge states of d0‐ to d3‐methylated peptides. An algorithm was developed that derived, without intervention, peptide sequence de novo by comparison of tandem mass spectra of d0‐ and d3‐peptide methyl esters. Copyright © 2001 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683
Cited by
Ong, S.-E., Blagoev, B., Kratchmarova, I., Kristensen, D. B., Steen, H., Pandey, A., & Mann, M. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200025-mcp200 · Cited by 5,574
Keller, A., Nesvizhskii, A. I., Kolker, E., & Aebersold, R. (2002) · Analytical Chemistry · doi:10.1021/ac025747h · Cited by 4,830
Self-citationA Statistical Model for Identifying Proteins by Tandem Mass Spectrometry
Nesvizhskii, A. I., Keller, A., Kolker, E., & Aebersold, R. (2003) · Analytical Chemistry · doi:10.1021/ac0341261 · Cited by 4,809
Self-citationAnderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Thompson, A., Schäfer, J., Kuhn, K., Kienle, S., Schwarz, J., Schmidt, G., Neumann, T., & Hamon, C. (2003) · Analytical Chemistry · doi:10.1021/ac0262560 · Cited by 2,378
Metadata
- Authors
- Goodlett, D. R., Keller, A., Watts, J. D., Newitt, R., Yi, E. C., Purvine, S., Eng, J. K., Haller, P. V., Aebersold, R., & Kolker, E.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2001-06-22
- Volume
- 15
- Issue
- 14
- Pages
- 1214-1221
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2127526794
- Cited by
- 281
- References
- 1
- FWCI
- 17.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.