The DOI matches its Crossref record.
Derivatization of sialic acids for stabilization in matrix‐assisted laser desorption/ionization mass spectrometry and concomitant differentiation of α (2 → 3)‐ and α (2 → 6)‐isomers
Abstract
Sialylated carbohydrates usually decompose by loss of sialic acid when ionized by matrix‐assisted laser desorption/ionization (MALDI) as the result of the labile carboxylic proton. Stabilization has previously been achieved by forming methyl esters with methyl iodide, a procedure that eliminates the labile proton. In this paper, we describe an alternative procedure for methyl ester formation that provides information on the sialic acid linkage directly from the MALDI spectrum. The sugars were desalted, dissolved in methanol, and treated with 4‐(4,6‐dimethoxy‐1,3,5‐triazin‐2‐yl)‐4‐methylmorpholinium chloride (DMT‐MM). After removal of the solvent, the products were transferred directly to the MALDI target and examined from 2,5‐dihydroxybenzoic acid. Small amounts of N ‐glycans derived from biological sources benefited from an additional clean‐up stage involving Nafion 117. α (2 → 6)‐Linked sialic acid produced only methyl esters whereas α (2 → 3)‐linked sialic acids were converted into their lactones providing a 32 Da difference in mass. Negative ion collision‐induced decomposition (CID) mass spectra of these neutralized glycans provided information, in many cases, on the antenna of N ‐linked glycans to which the variously linked sialic acids were attached. The method was applied to N ‐linked glycans released from bovine fetuin and porcine thyroglobulin. Copyright © 2008 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mass spectrometry approaches to glycomic and glycoproteomic analyses
Ruhaak, L. R., Xu, G., Li, Q., Goonatilleke, E., & Lebrilla, C. B. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00732 · Cited by 395
Reiding, K. R., Blank, D., Kuijper, D. M., Deelder, A. M., & Wuhrer, M. (2014) · Analytical Chemistry · doi:10.1021/ac500335t · Cited by 334
High-sensitivity Analytical Approaches for the Structural Characterization of Glycoproteins
Alley, W. R., Mann, B. F., & Novotny, M. V. (2013) · Chemical Reviews · doi:10.1021/cr3003714 · Cited by 310
Harvey, D. J. (2011) · Journal of Chromatography B · doi:10.1016/j.jchromb.2010.11.010 · Cited by 260
Self-citationHarvey, D. J. (2018) · Mass Spectrometry Reviews · doi:10.1002/mas.21530 · Cited by 61
Self-citation
Metadata
- Authors
- Wheeler, S. F., Domann, P., & Harvey, D. J.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2008-12-16
- Volume
- 23
- Issue
- 2
- Pages
- 303-312
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2002581274
- Cited by
- 169
- References
- 0
- FWCI
- 1.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Derivatization of sialic acids for stabilization in matrix‐assisted laser desorption/ionization mass spectrometry and concomitant differentiation of α (2 → 3)‐ and α (2 → 6)‐isomers. https://app.cochat.ai/papers/10.1002/rcm.3867
- The paper
- Wheeler, S. F., Domann, P., & Harvey, D. J. (2009). Derivatization of sialic acids for stabilization in matrix‐assisted laser desorption/ionization mass spectrometry and concomitant differentiation of α (2 → 3)‐ and α (2 → 6)‐isomers. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.3867
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.