Cavity ring‐down spectroscopy versus high‐temperature conversion isotope ratio mass spectrometry; a case study on δ 2 H and δ 18 O of pure water samples and alcohol/water mixtures
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Variation of O18 content of waters from natural sources
Epstein, S., & Mayeda, T. (1953) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(53)90051-9 · Cited by 3,216
Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources
O’Keefe, A., & Deacon, D. A. G. (1988) · Review of Scientific Instruments · doi:10.1063/1.1139895 · Cited by 1,741
Standards for stable isotope measurements in natural compounds
GONFIANTINI, R. (1978) · Nature · doi:10.1038/271534a0 · Cited by 1,081
Referencing strategies and techniques in stable isotope ratio analysis
Werner, R. A., & Brand, W. A. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.258 · Cited by 1,033
Self-citationCrosson, E. R. (2008) · Applied Physics B · doi:10.1007/s00340-008-3135-y · Cited by 598
Self-citationHigh-Precision Laser Spectroscopy D/H and 18O/16O Measurements of Microliter Natural Water Samples
Lis, G., Wassenaar, L. I., & Hendry, M. J. (2008) · Analytical Chemistry · doi:10.1021/ac701716q · Cited by 445
Coplen, T. B., Wildman, J. D., & Chen, J. (1991) · Analytical Chemistry · doi:10.1021/ac00009a014 · Cited by 352
Gupta, P., Noone, D., Galewsky, J., Sweeney, C., & Vaughn, B. H. (2009) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4100 · Cited by 351
Continuous flow 2 H/ 1 H and 18 O/ 16 O analysis of water samples with dual inlet precision
Gehre, M., Geilmann, H., Richter, J., Werner, R. A., & Brand, W. A. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1672 · Cited by 258
Self-citationConFlo III - an interface for high precision δ13C and δ15N analysis with an extended dynamic range
Werner, R. A., Bruch, B. A., & Brand, W. A. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990715)13:13<1237::aid-rcm633>3.0.co;2-c · Cited by 244
Self-citation
Cited by
Steen-Larsen, H. C., Johnsen, S. J., Masson-Delmotte, V., Stenni, B., Risi, C., Sodemann, H., Balslev-Clausen, D., Blunier, T., Dahl-Jensen, D., Ellehøj, M. D., et al. (2013) · Atmospheric Chemistry and Physics · doi:10.5194/acp-13-4815-2013 · Cited by 243
“CRDS uses time-based measurements of the exponential decay of light resonating in the optical cavity to quantify the optical loss at different optical wavelengths across a molecular absorption feature (Brand et al., 2009; Crosson et al., 2002).”
MethodGarcin, Y., Schwab, V. F., Gleixner, G., Kahmen, A., Todou, G., Séné, O., Onana, J.-M., Achoundong, G., & Sachse, D. (2012) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2011.11.039 · Cited by 186
“Down Spectrometry (CRDS) analyser (L1102–i, Picarro, Sunnyvale, USA) following the method described by Brand et al. (2009).”
Isotope‐ratio infrared spectroscopy: a reliable tool for the investigation of plant‐water sources?
Martín‐Gómez, P., Barbeta, A., Voltas, J., Peñuelas, J., Dennis, K., Palacio, S., Dawson, T. E., & Ferrio, J. P. (2015) · New Phytologist · doi:10.1111/nph.13376 · Cited by 178
“This allows the simultaneous measurement of 1H2 16O, 1H2 18O and 1H2H16O with an accuracy comparable to IRMS, at least when analysing pure water (Lis et al., 2008; Brand et al., 2009; Gupta et al., 2009; West et al., 2010, 2011).”
BackgroundMethodInfluentialHigh‐frequency field‐deployable isotope analyzer for hydrological applications
Berman, E. S. F., Gupta, M., Gabrielli, C., Garland, T., & McDonnell, J. J. (2009) · Water Resources Research · doi:10.1029/2009wr008265 · Cited by 159
“However, they are subject to erroneous readings if the water samples contain high levels of alcohols [Brand et al., 2009] or other dissolved organic carbon [Singleton et al., 2009].”
BackgroundMethodδ 18 O anchoring to VPDB: calcite digestion with 18 O‐adjusted ortho ‐phosphoric acid
Wendeberg, M., Richter, J. M., Rothe, M., & Brand, W. A. (2011) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4933 · Cited by 40
Self-citation
Metadata
- Authors
- Brand, W. A., Geilmann, H., Crosson, E. R., & Rella, C. W.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2009-05-15
- Volume
- 23
- Issue
- 12
- Pages
- 1879-1884
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2128415685
- Cited by
- 232
- References
- 13
- FWCI
- 6.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cavity ring‐down spectroscopy versus high‐temperature conversion isotope ratio mass spectrometry; a case study on δ 2 H and δ 18 O of pure water samples and alcohol/water mixtures. https://app.cochat.ai/papers/10.1002/rcm.4083
- The paper
- Brand, W. A., Geilmann, H., Crosson, E. R., & Rella, C. W. (2009). Cavity ring‐down spectroscopy versus high‐temperature conversion isotope ratio mass spectrometry; a case study on δ 2 H and δ 18 O of pure water samples and alcohol/water mixtures. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.4083
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.