Quantification of 15‐F 2t ‐isoprostane in human plasma and urine: results from enzyme‐linked immunoassay and liquid chromatography/tandem mass spectrometry cannot be compared
The DOI matches its Crossref record.
Abstract
Quantification of F 2 ‐isoprostanes is considered a reliable index of the oxidative stress status in vivo . Several immunoassays and chromatography/mass spectrometry‐based assays are available for 15‐F 2t ‐isoprostane quantification. However, it remains unclear if results of immunoassays using different assays can be compared with those of liquid chromatography/mass spectrometry (LC/MS) assays. Previous studies comparing enzyme‐linked immunosorbent assay (ELISA) and more specific gas chromatography/mass spectrometry assays have already indicated that ELISAs may overestimate 15‐F 2t ‐isoprostane concentrations in human plasma. Concentrations of 15‐F 2t ‐isoprostane in 25 human plasma and urine samples were measured by three commercially available ELISA assays (Assay Designs, Cayman Chemical and Oxford Biomedical Research) and compared with the concentrations measured with a validated, semi‐automated high‐throughput HPLC tandem mass spectrometry assay (LC/LC‐MS/MS). All three ELISAs measured substantially higher 15‐F 2t ‐isoprostane concentrations (2.1–182.2‐fold higher in plasma; 0.4–61.9‐fold higher in urine) than LC/LC‐MS/MS. Utilization of solid‐phase extraction (SPE) columns, especially isoprostane affinity purification columns, brought ELISA isoprostane urine concentrations closer to the LC/LC‐MS/MS results. However, SPE did not have much of an effect on ELISA plasma concentrations which remained significantly higher than corresponding LC/LC‐MS/MS results. A poor correlation not only between LC/LC‐MS/MS and immunoassay results, but also among the immunoassays was found. Especially in plasma, ELISAs grossly overestimate 15‐F 2t ‐isoprostane concentrations and are not comparable with each other or with LC/LC‐MS/MS. It is most disturbing that a sample with relatively high concentrations measured with one ELISA may show low concentrations with another ELISA, and vice versa, potentially affecting the conclusions drawn from such data. The use of specific mass spectrometry‐based assays seems advisable. Copyright © 2011 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Griendling, K. K., Touyz, R. M., Zweier, J. L., Dikalov, S., Chilian, W., Chen, Y.-R., Harrison, D. G., & Bhatnagar, A. (2016) · Circulation Research · doi:10.1161/res.0000000000000110 · Cited by 444
The isoprostanes—25 years later
Milne, G. L., Dai, Q., & Roberts, L. J. (2015) · Biochimica et Biophysica Acta (BBA) - Molecular and Cell Biology of Lipids · doi:10.1016/j.bbalip.2014.10.007 · Cited by 335
The antioxidant paradox: less paradoxical now?
Halliwell, B. (2013) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.2012.04272.x · Cited by 318
Lipoxidation in cardiovascular diseases
Gianazza, E., Brioschi, M., Fernandez, A. M., & Banfi, C. (2019) · Redox Biology · doi:10.1016/j.redox.2019.101119 · Cited by 152
Metadata
- Authors
- Klawitter, J., Haschke, M., Shokati, T., Klawitter, J., & Christians, U.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2011-01-13
- Volume
- 25
- Issue
- 4
- Pages
- 463-468
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W1989841540
- Cited by
- 86
- References
- 0
- FWCI
- 4.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.