Measuring long‐chain acyl‐coenzyme A concentrations and enrichment using liquid chromatography/tandem mass spectrometry with selected reaction monitoring
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Long‐chain acyl‐coenzymes A (acyl‐CoAs) (LCACoA) are the activated forms of long‐chain fatty acids and serve as key lipid metabolites. Excess accumulation of intracellular LCACoA, diacylglycerols (DAGs) and ceramides may create insulin resistance with respect to glucose metabolism. We present a new method to measure LCACoA concentrations and isotopic enrichment of palmitoyl‐CoA ([U‐ 13 C]16‐CoA) and oleoyl‐CoA ([U‐ 13 C]18:1‐CoA) using ultra‐performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) to quantitate seven different LCACoA (C14‐CoA, C16‐CoA, C16:1‐CoA, C18‐CoA, C18:1‐CoA, C18:2‐CoA, C20‐CoA). The molecules are separated on a reversed‐phase UPLC column using a binary gradient with ammonium hydroxide (NH 4 OH) in water and NH 4 OH in acetonitrile (ACN). The LCACoA are quantified using selected reaction monitoring (SRM) on a triple quadrupole mass spectrometer in positive electrospray ionization (ESI) mode. All LCACoA ions except enriched palmitate enrichment of palmitoyl‐CoA ([U −13 C]16‐CoA) and oleoyl‐CoA ([U −13 C]18:1‐CoA) using ultra‐performance liquid chromatography/mass spectrometry (UPLC/MS/MS) to quantitate seven different LCACoA (C14‐CoA, C16‐CoA, C16:1‐CoA, C18‐CoA, C18:1‐CoA, C18:2‐CoA, C20‐CoA). The molecules are separated on a reversed‐phase UPLC column using a binary gradient with ammonium hydroxide (NH 4 OH) in water and NH 4 OH in acetonitrile. The LCACoA are quantified using selected reaction monitoring (SRM) on a triple quadrupolemass spectrometer in positive electrospray ionization (ESI) mode. All LCACoA ions except enriched palmitate and oleate were monitored as [M + 2 + H] + and [U 13 C]16‐CoA and [U 13 C]18:1‐CoA were monitored as [M + 16 + H] + and [M + 18 + H] + , respectively. The method is simple, sensitive and efficient (run time as short as 5 min) and allowed us to measure the concentration and detect enrichment in intramyocellular [U 13 C]16‐CoA and [U 13 C]18:1‐CoA during a low dose intravenous infusion of [U 13 C]palmitate and [U 13 C]oleate in adults undergoing either a saline control experiment or an insulin/glucose infusion experiment. This technique should allow investigators to measure the trafficking of extracellular fatty acids to the intracellular LCACoA pool. Copyright © 2011 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yu, C., Chen, Y., Cline, G. W., Zhang, D., Zong, H., Wang, Y., Bergeron, R., Kim, J. K., Cushman, S. W., Cooney, G. J., et al. (2002) · Journal of Biological Chemistry · doi:10.1074/jbc.m200958200 · Cited by 1,561
Ellis, B. A., Poynten, A., Lowy, A. J., Furler, S. M., Chisholm, D. J., Kraegen, E. W., & Cooney, G. J. (2000) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2000.279.3.e554 · Cited by 273
Kinetics of intramuscular triglyceride fatty acids in exercising humans
Guo, Z., Burguera, B., & Jensen, M. D. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.5.2057 · Cited by 110
Self-citationKanaley, J. A., Shadid, S., Sheehan, M. T., Guo, Z., & Jensen, M. D. (2009) · The Journal of Physiology · doi:10.1113/jphysiol.2009.180695 · Cited by 92
Self-citation
Cited by
Lanza, I. R., Blachnio-Zabielska, A., Johnson, M. L., Schimke, J. M., Jakaitis, D. R., Lebrasseur, N. K., Jensen, M. D., Sreekumaran Nair, K., & Zabielski, P. (2013) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00584.2012 · Cited by 135
Self-citationZabielski, P., Blachnio-Zabielska, A., Lanza, I. R., Gopala, S., Manjunatha, S., Jakaitis, D. R., Persson, X.-M., Gransee, J., Klaus, K. A., Schimke, J. M., et al. (2014) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00610.2012 · Cited by 30
Self-citationCosta, D. N., Santosa, S., & Jensen, M. D. (2025) · Physiological Reviews · doi:10.1152/physrev.00008.2024 · Cited by 34
Self-citation
Metadata
- Authors
- Blachnio‐Zabielska, A. U., Koutsari, C., & Jensen, M. D.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2011-07-06
- Volume
- 25
- Issue
- 15
- Pages
- 2223-2230
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W1586033476
- Cited by
- 46
- References
- 4
- FWCI
- 2.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measuring long‐chain acyl‐coenzyme A concentrations and enrichment using liquid chromatography/tandem mass spectrometry with selected reaction monitoring. https://app.cochat.ai/papers/10.1002/rcm.5110
- The paper
- Blachnio‐Zabielska, A. U., Koutsari, C., & Jensen, M. D. (2011). Measuring long‐chain acyl‐coenzyme A concentrations and enrichment using liquid chromatography/tandem mass spectrometry with selected reaction monitoring. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.5110
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.