CoChat

Measuring long‐chain acyl‐coenzyme A concentrations and enrichment using liquid chromatography/tandem mass spectrometry with selected reaction monitoring

Open access
Blachnio‐Zabielska, Agnieszka U., Koutsari, Christina, Jensen, Michael D. · 2011 · Rapid Communications in Mass Spectrometry
Cited by 46

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Long‐chain acyl‐coenzymes A (acyl‐CoAs) (LCACoA) are the activated forms of long‐chain fatty acids and serve as key lipid metabolites. Excess accumulation of intracellular LCACoA, diacylglycerols (DAGs) and ceramides may create insulin resistance with respect to glucose metabolism. We present a new method to measure LCACoA concentrations and isotopic enrichment of palmitoyl‐CoA ([U‐ 13 C]16‐CoA) and oleoyl‐CoA ([U‐ 13 C]18:1‐CoA) using ultra‐performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) to quantitate seven different LCACoA (C14‐CoA, C16‐CoA, C16:1‐CoA, C18‐CoA, C18:1‐CoA, C18:2‐CoA, C20‐CoA). The molecules are separated on a reversed‐phase UPLC column using a binary gradient with ammonium hydroxide (NH 4 OH) in water and NH 4 OH in acetonitrile (ACN). The LCACoA are quantified using selected reaction monitoring (SRM) on a triple quadrupole mass spectrometer in positive electrospray ionization (ESI) mode. All LCACoA ions except enriched palmitate enrichment of palmitoyl‐CoA ([U −13 C]16‐CoA) and oleoyl‐CoA ([U −13 C]18:1‐CoA) using ultra‐performance liquid chromatography/mass spectrometry (UPLC/MS/MS) to quantitate seven different LCACoA (C14‐CoA, C16‐CoA, C16:1‐CoA, C18‐CoA, C18:1‐CoA, C18:2‐CoA, C20‐CoA). The molecules are separated on a reversed‐phase UPLC column using a binary gradient with ammonium hydroxide (NH 4 OH) in water and NH 4 OH in acetonitrile. The LCACoA are quantified using selected reaction monitoring (SRM) on a triple quadrupolemass spectrometer in positive electrospray ionization (ESI) mode. All LCACoA ions except enriched palmitate and oleate were monitored as [M + 2 + H] + and [U 13 C]16‐CoA and [U 13 C]18:1‐CoA were monitored as [M + 16 + H] + and [M + 18 + H] + , respectively. The method is simple, sensitive and efficient (run time as short as 5 min) and allowed us to measure the concentration and detect enrichment in intramyocellular [U 13 C]16‐CoA and [U 13 C]18:1‐CoA during a low dose intravenous infusion of [U 13 C]palmitate and [U 13 C]oleate in adults undergoing either a saline control experiment or an insulin/glucose infusion experiment. This technique should allow investigators to measure the trafficking of extracellular fatty acids to the intracellular LCACoA pool. Copyright © 2011 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.5110

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 46

Metadata

Authors
Blachnio‐Zabielska, A. U., Koutsari, C., & Jensen, M. D.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2011-07-06
Volume
25
Issue
15
Pages
2223-2230
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W1586033476
Cited by
46
References
4
FWCI
2.00
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measuring long‐chain acyl‐coenzyme A concentrations and enrichment using liquid chromatography/tandem mass spectrometry with selected reaction monitoring. https://app.cochat.ai/papers/10.1002/rcm.5110
The paper
Blachnio‐Zabielska, A. U., Koutsari, C., & Jensen, M. D. (2011). Measuring long‐chain acyl‐coenzyme A concentrations and enrichment using liquid chromatography/tandem mass spectrometry with selected reaction monitoring. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.5110

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.