CoChat

Traveling‐wave ion mobility mass spectrometry of protein complexes: accurate calibrated collision cross‐sections of human insulin oligomers

Salbo, Rune, Bush, Matthew F., Naver, Helle, Campuzano, Iain, Robinson, Carol V., Pettersson, Ingrid, Jørgensen, Thomas J. D., Haselmann, Kim F. · 2012 · Rapid Communications in Mass Spectrometry
Cited by 168

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

RATIONALE: The collision cross‐section (Ω) of a protein or protein complex ion can be measured using traveling‐wave (T‐wave) ion mobility (IM) mass spectrometry (MS) via calibration with compounds of known Ω. The T‐wave Ω‐values depend strongly on instrument parameters and calibrant selection. Optimization of instrument parameters and calibration standards are crucial for obtaining accurate T‐wave Ω‐values. METHODS: Human insulin and the fast‐acting insulin aspart under native‐like conditions (ammonium acetate, physiological pH) were analyzed on Waters SYNAPT G1 and G2 HDMS instruments. The calibrated T‐wave Ω‐values of insulin monomer, dimer, and hexamer ions were measured using many different combinations of denatured and native‐like calibrants (masses between 2.85 and 256 kDa) and T‐wave conditions. Drift‐tube Ω‐values were obtained on a modified SYNAPT G1. RESULTS: Insulin T‐wave Ω‐values were measured at 26 combinations of T‐wave velocity and amplitude. Optimal sets of calibrants were identified that yield Ω‐values with minimal dependence on T‐wave conditions and calibration plots with high R 2 ‐values. The T‐wave Ω‐values determined under conditions satisfying these criteria had absolute errors <2%. Structural differences between human insulin and fast‐acting insulin aspart were probed with IM‐MS. Insulin aspart monomers have increased flexibility, while hexamers are more compact than human insulin. CONCLUSIONS: Accurate T‐wave Ω‐values that are indistinguishable from drift‐tube values are obtained when using (1) native‐like calibrants with masses that closely bracket that of the analyte, (2) T‐wave velocities that maximize the R 2 of the calibration plot for those calibrants, and (3) at least three replicates at T‐wave velocities that yield calibration plots with high R 2 . Copyright © 2012 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.6211

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 168

Metadata

Authors
Salbo, R., Bush, M. F., Naver, H., Campuzano, I., Robinson, C. V., Pettersson, I., Jørgensen, T. J. D., & Haselmann, K. F.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2012-04-13
Volume
26
Issue
10
Pages
1181-1193
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2123911097
Cited by
168
References
2
FWCI
7.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.