Traveling‐wave ion mobility mass spectrometry of protein complexes: accurate calibrated collision cross‐sections of human insulin oligomers
The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
RATIONALE: The collision cross‐section (Ω) of a protein or protein complex ion can be measured using traveling‐wave (T‐wave) ion mobility (IM) mass spectrometry (MS) via calibration with compounds of known Ω. The T‐wave Ω‐values depend strongly on instrument parameters and calibrant selection. Optimization of instrument parameters and calibration standards are crucial for obtaining accurate T‐wave Ω‐values. METHODS: Human insulin and the fast‐acting insulin aspart under native‐like conditions (ammonium acetate, physiological pH) were analyzed on Waters SYNAPT G1 and G2 HDMS instruments. The calibrated T‐wave Ω‐values of insulin monomer, dimer, and hexamer ions were measured using many different combinations of denatured and native‐like calibrants (masses between 2.85 and 256 kDa) and T‐wave conditions. Drift‐tube Ω‐values were obtained on a modified SYNAPT G1. RESULTS: Insulin T‐wave Ω‐values were measured at 26 combinations of T‐wave velocity and amplitude. Optimal sets of calibrants were identified that yield Ω‐values with minimal dependence on T‐wave conditions and calibration plots with high R 2 ‐values. The T‐wave Ω‐values determined under conditions satisfying these criteria had absolute errors <2%. Structural differences between human insulin and fast‐acting insulin aspart were probed with IM‐MS. Insulin aspart monomers have increased flexibility, while hexamers are more compact than human insulin. CONCLUSIONS: Accurate T‐wave Ω‐values that are indistinguishable from drift‐tube values are obtained when using (1) native‐like calibrants with masses that closely bracket that of the analyte, (2) T‐wave velocities that maximize the R 2 of the calibration plot for those calibrants, and (3) at least three replicates at T‐wave velocities that yield calibration plots with high R 2 . Copyright © 2012 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amos, A. F., McCarty, D. J., & Zimmet, P. (1997) · Diabetic Medicine · doi:10.1002/(sici)1096-9136(199712)14:5+<s7::aid-dia522>3.0.co;2-r · Cited by 1,882
Transport Properties of Ions in Gases
Mason, E. A., & McDaniel, E. W. (1988) · Wiley eBooks · doi:10.1002/3527602852 · Cited by 1,797
Structure of ubiquitin refined at 1.8 Å resolution
Vijay-kumar, S., Bugg, C. E., & Cook, W. J. (1987) · Journal of Molecular Biology · doi:10.1016/0022-2836(87)90679-6 · Cited by 1,742
Ion mobility–mass spectrometry
Kanu, A. B., Dwivedi, P., Tam, M., Matz, L., & Hill, H. H. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1383 · Cited by 1,154
Ion mobility–mass spectrometry analysis of large protein complexes
Ruotolo, B. T., Benesch, J. L. P., Sandercock, A. M., Hyung, S.-J., & Robinson, C. V. (2008) · Nature Protocols · doi:10.1038/nprot.2008.78 · Cited by 1,092
Self-citationBernstein, S. L., Dupuis, N. F., Lazo, N. D., Wyttenbach, T., Condron, M. M., Bitan, G., Teplow, D. B., Shea, J.-E., Ruotolo, B. T., Robinson, C. V., et al. (2009) · Nature Chemistry · doi:10.1038/nchem.247 · Cited by 918
Self-citationInsulin: The Structure in the Crystal and its Reflection in Chemistry and Biology by
Blundell, T., Dodson, G., Hodgkin, D., & Mercola, D. (1972) · Advances in Protein Chemistry · doi:10.1016/s0065-3233(08)60143-6 · Cited by 836
Pringle, S. D., Giles, K., Wildgoose, J. L., Williams, J. P., Slade, S. E., Thalassinos, K., Bateman, R. H., Bowers, M. T., & Scrivens, J. H. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.07.021 · Cited by 808
Bush, M. F., Hall, Z., Giles, K., Hoyes, J., Robinson, C. V., & Ruotolo, B. T. (2010) · Analytical Chemistry · doi:10.1021/ac1022953 · Cited by 796
Self-citationApplications of a travelling wave‐based radio‐frequency‐only stacked ring ion guide
Giles, K., Pringle, S. D., Worthington, K. R., Little, D., Wildgoose, J. L., & Bateman, R. H. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1641 · Cited by 727
Cited by
Recommendations for reporting ion mobility Mass Spectrometry measurements
Gabelica, V., Shvartsburg, A. A., Afonso, C., Barran, P., Benesch, J. L. P., Bleiholder, C., Bowers, M. T., Bilbao, A., Bush, M. F., Campbell, J. L., et al. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21585 · Cited by 493
“For ESI, other calibrants were thus used (Wyttenbach, Von Helden, & Bowers, 1996; Hoaglund et al., 1997; Shelimov et al., 1997; Valentine et al., 1997; Valentine, Counterman, & Clemmer, 1997; Counterman et al., 1998; Hoaglund et al., 1998; Wyttenbach, Bushnell, & Bowers, 1998; Henderson et al., 1999a,b; Valentine, Cou…”
BackgroundSelf-citationIon Mobility-Mass Spectrometry: Time-Dispersive Instrumentation
May, J. C., & McLean, J. A. (2015) · Analytical Chemistry · doi:10.1021/ac504720m · Cited by 435
May, J. C., Goodwin, C. R., Lareau, N. M., Leaptrot, K. L., Morris, C. B., Kurulugama, R. T., Mordehai, A., Klein, C., Barry, W., Darland, E., et al. (2014) · Analytical Chemistry · doi:10.1021/ac4038448 · Cited by 401
Ion Mobility Mass Spectrometry of Peptide Ions: Effects of Drift Gas and Calibration Strategies
Bush, M. F., Campuzano, I. D. G., & Robinson, C. V. (2012) · Analytical Chemistry · doi:10.1021/ac3014498 · Cited by 315
Self-citationNative ion mobility-mass spectrometry and related methods in structural biology
Konijnenberg, A., Butterer, A., & Sobott, F. (2013) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2012.11.013 · Cited by 245
Zhou, M., Dagan, S., & Wysocki, V. H. (2013) · The Analyst · doi:10.1039/c2an36525a · Cited by 92
Turzo, S. B. A., Seffernick, J. T., Rolland, A. D., Donor, M. T., Heinze, S., Prell, J. S., Wysocki, V. H., & Lindert, S. (2022) · Nature Communications · doi:10.1038/s41467-022-32075-9 · Cited by 47
Ion mobility in the pharmaceutical industry: an established biophysical technique or still niche?
Campuzano, I. D., & Lippens, J. L. (2018) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2017.11.008 · Cited by 42
Self-citation
Metadata
- Authors
- Salbo, R., Bush, M. F., Naver, H., Campuzano, I., Robinson, C. V., Pettersson, I., Jørgensen, T. J. D., & Haselmann, K. F.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2012-04-13
- Volume
- 26
- Issue
- 10
- Pages
- 1181-1193
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2123911097
- Cited by
- 168
- References
- 54
- FWCI
- 7.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.