CoChat

Confident identification of isomeric N ‐glycan structures by combined ion mobility mass spectrometry and hydrophilic interaction liquid chromatography

Yamaguchi, Yoshiki, Nishima, Wataru, Re, Suyong, Sugita, Yuji · 2012 · Rapid Communications in Mass Spectrometry
Cited by 56

The DOI matches its Crossref record.

Abstract

RATIONALE: A central issue in glycan mass analysis is the ambiguity of structural assignments due to the heterogeneity and complexity of glycan structures. Ion mobility mass spectrometry (IM‐MS) has the potential to separate isomeric glycans depending on their unique collisional cross section especially when coupled with hydrophilic interaction liquid chromatography (HILIC). METHODS: Ten pyridylaminated biantennary N ‐glycans including isomeric structures were measured by electrospray ionization quadrupole‐time‐of‐flight mass spectrometry with an ion mobility phase. We investigated which adduct ions would be suitable for good separation in the ion mobility phase. The differences in observed drift time of isomeric glycans were assessed by molecular dynamics (MD) simulations in vacuum. Connecting an HILIC system with IM‐MS provided another, augmented separation mode. RESULTS: By selecting doubly protonated precursor ion species, we succeeded in separating a pair of isomeric glycans in the ion mobility phase with reasonable resolution. MD simulations of monogalactosylated glycan isomers indicate that the galactosylated Man α1‐3 branch preferentially folds back to the core chitobiose portion to form a compact structure. IM‐MS combined with HILIC resulted in even clearer separation of isomeric glycans within 15 min. CONCLUSIONS: A combination of IM‐MS with an HILIC system is eminently suitable for the confident and rapid distinction of glycan structures within a defined mixture. Copyright © 2012 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.6412

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 56

Metadata

Authors
Yamaguchi, Y., Nishima, W., Re, S., & Sugita, Y.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2012-11-05
Volume
26
Issue
24
Pages
2877-2884
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2142335003
Cited by
56
References
0
FWCI
2.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Confident identification of isomeric N ‐glycan structures by combined ion mobility mass spectrometry and hydrophilic interaction liquid chromatography. https://app.cochat.ai/papers/10.1002/rcm.6412
The paper
Yamaguchi, Y., Nishima, W., Re, S., & Sugita, Y. (2012). Confident identification of isomeric N ‐glycan structures by combined ion mobility mass spectrometry and hydrophilic interaction liquid chromatography. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.6412

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.