The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Measurement of SLAP2 and GISP δ 17 O and proposed VSMOW‐SLAP normalization for δ 17 O and 17 O excess
Abstract
RATIONALE: The absence of an agreed‐upon δ 17 O value for the primary reference water SLAP leads to significant discrepancies in the reported values of δ 17 O and the parameter 17 O excess . The accuracy of δ 17 O and 17 O excess values is significantly improved if the measurements are normalized using a two‐point calibration, following the convention for δ 2 H and δ 18 O values. METHODS: New measurements of the δ 17 O values of SLAP2 and GISP are presented and compared with published data. Water samples were fluorinated with CoF 3 . Helium carried the O 2 product to a 5A (4.2 to 4.4 Å) molecular sieve trap submerged in liquid nitrogen. The O 2 sample was introduced into a dual‐inlet ThermoFinnigan MAT 253 isotope ratio mass spectrometer for measurement of m/z 32, 33, and 34. The δ 18 O and δ 17 O values were calculated after 90 comparisons with an O 2 reference gas. RESULTS: We propose that the accepted δ 17 O value of SLAP be defined in terms of δ 18 O = −55.5 ‰ and 17 O excess = 0, yielding a δ 17 O value of approximately −29.6968 ‰. Using this definition for SLAP and the recommended normalization procedure, the δ 17 O value of GISP is −13.16 ± 0.05 ‰ and the 17 O excess value of GISP is 22 ± 11 per meg. Correcting previous published values of GISP δ 17 O to both VSMOW and SLAP improves the inter‐laboratory precision by about 10 per meg. CONCLUSIONS: The data generated here and compiled from previous studies provide a substantial volume of evidence to evaluate the various normalization techniques currently used for triple oxygen isotope measurements. We recommend that reported δ 17 O and 17 O excess values be normalized to the VSMOW‐SLAP scale, using a definition of SLAP such that its 17 O excess is exactly zero. Copyright © 2013 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standard for Reporting Concentrations of Deuterium and Oxygen-18 in Natural Waters
Craig, H. (1961) · Science · doi:10.1126/science.133.3467.1833 · Cited by 2,013
Cited by
Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical Report)
Brand, W. A., Coplen, T. B., Vogl, J., Rosner, M., & Prohaska, T. (2014) · Pure and Applied Chemistry · doi:10.1515/pac-2013-1023 · Cited by 704
Stable isotopes in atmospheric water vapor and applications to the hydrologic cycle
Galewsky, J., Steen‐Larsen, H. C., Field, R. D., Worden, J., Risi, C., & Schneider, M. (2016) · Reviews of Geophysics · doi:10.1002/2015rg000512 · Cited by 489
Schauer, A. J., Kelson, J., Saenger, C., & Huntington, K. W. (2016) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.7743 · Cited by 157
Self-citationA stable isotope toolbox for water and inorganic carbon cycle studies
Hillaire-Marcel, C., Kim, S.-T., Landais, A., Ghosh, P., Assonov, S., Lécuyer, C., Blanchard, M., Meijer, H. A. J., & Steen-Larsen, H. C. (2021) · Nature Reviews Earth & Environment · doi:10.1038/s43017-021-00209-0 · Cited by 43
Saenger, C. P., Schauer, A. J., Heitmann, E. O., Huntington, K. W., & Steig, E. J. (2021) · Chemical Geology · doi:10.1016/j.chemgeo.2021.120059 · Cited by 11
Self-citation
Metadata
- Authors
- Schoenemann, S. W., Schauer, A. J., & Steig, E. J.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2013-02-12
- Volume
- 27
- Issue
- 5
- Pages
- 582-590
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2078646697
- Cited by
- 161
- References
- 1
- FWCI
- 13.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.