Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 161

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Measurement of SLAP2 and GISP δ 17 O and proposed VSMOW‐SLAP normalization for δ 17 O and 17 O excess

Schoenemann, Spruce W., Schauer, Andrew J., Steig, Eric J. · 2013 · Rapid Communications in Mass Spectrometry

Abstract

RATIONALE: The absence of an agreed‐upon δ 17 O value for the primary reference water SLAP leads to significant discrepancies in the reported values of δ 17 O and the parameter 17 O excess . The accuracy of δ 17 O and 17 O excess values is significantly improved if the measurements are normalized using a two‐point calibration, following the convention for δ 2 H and δ 18 O values. METHODS: New measurements of the δ 17 O values of SLAP2 and GISP are presented and compared with published data. Water samples were fluorinated with CoF 3 . Helium carried the O 2 product to a 5A (4.2 to 4.4 Å) molecular sieve trap submerged in liquid nitrogen. The O 2 sample was introduced into a dual‐inlet ThermoFinnigan MAT 253 isotope ratio mass spectrometer for measurement of m/z 32, 33, and 34. The δ 18 O and δ 17 O values were calculated after 90 comparisons with an O 2 reference gas. RESULTS: We propose that the accepted δ 17 O value of SLAP be defined in terms of δ 18 O = −55.5 ‰ and 17 O excess = 0, yielding a δ 17 O value of approximately −29.6968 ‰. Using this definition for SLAP and the recommended normalization procedure, the δ 17 O value of GISP is −13.16 ± 0.05 ‰ and the 17 O excess value of GISP is 22 ± 11 per meg. Correcting previous published values of GISP δ 17 O to both VSMOW and SLAP improves the inter‐laboratory precision by about 10 per meg. CONCLUSIONS: The data generated here and compiled from previous studies provide a substantial volume of evidence to evaluate the various normalization techniques currently used for triple oxygen isotope measurements. We recommend that reported δ 17 O and 17 O excess values be normalized to the VSMOW‐SLAP scale, using a definition of SLAP such that its 17 O excess is exactly zero. Copyright © 2013 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.6486

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 161

Metadata

Authors
Schoenemann, S. W., Schauer, A. J., & Steig, E. J.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2013-02-12
Volume
27
Issue
5
Pages
582-590
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2078646697
Cited by
161
References
1
FWCI
13.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.