CoChat

The oxygen isotope composition of San Carlos olivine on the VSMOW2‐SLAP2 scale

Pack, Andreas, Tanaka, Ryoji, Hering, Markus, Sengupta, Sukanya, Peters, Stefan, Nakamura, Eizo · 2016 · Rapid Communications in Mass Spectrometry
Cited by 125

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Rationale: The precise determination of Δ' 17 O values in terrestrial material is becoming increasingly important to understand the mass‐dependent fractionation processes that cause variations in oxygen isotope ratios. San Carlos olivine is widely used as the reference material for oxygen isotope measurements of terrestrial and extraterrestrial materials. We report new Δ' 17 O values for San Carlos olivine that were independently determined in two different laboratories (Geoscience Center [GZG], University of Göttingen) and Institute for Study of the Earth's Interior [ISEI], Okayama University, Misasa) in direct comparison with VSMOW2 and SLAP2 water standards. Methods: The δ 17 O and δ 18 O values of VSMOW2, SLAP2, GISP, and San Carlos olivine were determined relative to reference gas. In both laboratories, water and San Carlos olivine samples were prepared by BrF 5 fluorination. In both laboratories, the O 2 released from water and olivine samples was passed through the same purification system and measured using the same mass spectrometer relative to the same reference gas. Results: In both laboratories, the δ 17 O VSMOW2 and δ 18 O VSMOW2 scales were slightly compressed with respect to the recommended composition of VSMOW2 and SLAP2. The new Δ' 17 O 0 .528 value (calculated from the VSMOW2‐SLAP2 scaled δ values) of San Carlos olivine from GZG was −36 ± 9 ppm and, from ISEI, a value of −40 ± 7 ppm (1σ standard deviation) was determined. These values are ~50 ppm higher than previously reported from the same laboratories. Possible causes for the observed discrepancies are discussed. Conclusions: The results of this study in comparison with previous data from the same laboratories demonstrated that for high accuracy determination of Δ' 17 O values: (i) calibration of the reference gas relative to O 2 released from primary standards (VSMOW2, SLAP2) in the same laboratory is highly recommended, (ii) non‐linearity of the mass spectrometer may not only affect δ 17 O and δ 18 O values but also Δ' 17 O values, and (iii) the VSMOW2‐SLAP2 scaling should also be applied to analyses of rocks and minerals. Studies that are concerned with small differences in Δ' 17 O at similar δ 18 O values, however, are not affected by non‐linearity of the mass spectrometer. Copyright © 2016 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.7582

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 125

Metadata

Authors
Pack, A., Tanaka, R., Hering, M., Sengupta, S., Peters, S., & Nakamura, E.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2016-06-08
Volume
30
Issue
13
Pages
1495-1504
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2461477051
Cited by
125
References
1
FWCI
9.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.