Sheathless interface to match flow rate of capillary electrophoresis with electrospray mass spectrometry using regular‐sized capillary
Open accessAbstract
Rationale: The flow rate match has been a great challenge when coupling capillary electrophoresis (CE) with electrospray ionization mass spectrometry (ESI‐MS). Conventional CE‐ESI‐MS interfaces used liquid sheath flow, narrowed capillary or additional pressure to meet this requirement; sacrifice of either capillary inner diameter (i.d.) or separation efficiency is often inevitable. Thus, a regular‐sized capillary‐based sheathless interface would be attractive for flow rate match in CE‐MS. Methods: The regular‐sized capillary‐based CE‐MS interface was achieved by coupling CE with induced electrospray ionization (iESI) which was stimulated by the fact that the iESI could both achieve flow rate down to 0.2 μ L/min and retain ionization efficiency. The CE‐iESI‐MS interface was completed with an intact separation capillary, outside the outlet end of which a metal electrode was attached for the application of alternating current (ac) high voltage (HV). Results: The feasibility of this CE‐iESI‐MS interface was demonstrated through the stable total ion chromatograms obtained by continuous CE infusion of tripropylamine with regular‐sized capillaries. Tripropylamine and atenolol were separated and detected successfully in phosphate buffer solution (PBS) by CE‐iESI‐MS using a 50 or 75 μ m i.d. capillary. Furthermore, this new interface showed a better signal‐to‐noise (S/N) of 3 to 7 times enhancement compared with another sheathless CE‐ESI‐MS interface that using one high voltage for both separation and electrospray when analyzing the mixture of tripropylamine and proline in NH 4 OAc buffer. In addition, the reproducibility of this interface gave satisfactory results with relative standard deviation (RSD) in retention time in the range between 1% and 3%. Conclusions: The novel sheathless CE‐MS interface introduced here could match conventional electroosmotic flow (EOF) with electrospray which could also preserve the separation efficiency and sensitivity of CE‐MS. This newly developed CE‐iESI‐MS interface was also demonstrated to be effective for different buffers, PBS and NH 4 OAc, without any additives such as methanol and acetic acid. Hence, we believe that this sheathless CE‐MS interface could be operated with other nonvolatile and volatile buffers. Copyright © 2016 John Wiley & Sons, Ltd.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The sheathless interface can significantly enhance signal-to-noise because analyte dilution and background noise are decreased when the BGE is the only liquid.
“In contrast, the sheathless interface can significantly enhance signal/noise due to decreased analyte dilution and background noise, as the BGE is the only liquid in the system5,54.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [54]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cited by
Sorted by citations
Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research
Gomes, F. P., & Yates, J. R. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21599 · Cited by 112 · see citing works
- Authors
- Yin, Y., Li, G., Guan, Y., & Huang, G.
- Affiliations
- University of Science and Technology of China (CN)
- Dalian Institute of Chemical Physics (CN)
- Corresponding author
- Huang, Guangming
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2016-08
- Volume
- 30
- Issue
- S1
- Pages
- 68-72
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2527297884
- Cited by
- 11
- References
- 0
- Citations by year
- 2025: 1 · 2023: 1 · 2022: 1 · 2021: 1 · 2020: 2 · 2019: 2 · 2018: 2 · 2016: 1
- FWCI
- 0.83
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Rapid Communications in Mass Spectrometry (publishedVersion)
- PubMed (publishedVersion)
- Dalian Institute of Chemical Physics, CAS Institutional Repository (submittedVersion)
- Funders
- National Natural Science Foundation of China (21205111)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrohydrodynamics and Fluid Dynamics
- Keywords
- capillary electrophoresis, electrospray ionization, CE-MS coupling, electroosmotic flow, tripropylamine, atenolol, proline, signal-to-noise ratio improvement, retention time reproducibility, acetonitrile
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review