Measurement of the accurate mass of a 50 MDa infectious virus
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Rationale: Bacteriophage P22 is believed to contain a total of 521 copies of 9 different proteins and a 41,724 base pair genome. Despite its enormous size and complexity, phage P22 can be electrosprayed, and it remains intact in ultra‐high vacuum where its molar mass distribution has been measured. Methods: Phage P22 virions were generated by complementation in Salmonella enterica and purified. They were transferred into 100 mM ammonium acetate and then electrosprayed. The masses of individual virions were determined using charge detection mass spectrometry. Results: The stoichiometry of the protein components of phage P22 is sufficiently well known that the theoretical molar mass can be determined to within a narrow range. The measured average molar mass of phage P22, 52,180 ± 59 kDa, is consistent with the theoretical molar mass and supports the proposed stoichiometry of the components. The intrinsic width of the phage P22 mass distribution can be accounted for by the distribution of DNA packaged by the headful mechanism. Conclusions: At over 50 MDa, phage P22 is the largest object with a well‐defined molar mass to be analyzed by mass spectrometry. The narrow measured mass distribution indicates that the virions survive the transition into the gas phase intact. Copyright © 2016 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Snijder, J., van de Waterbeemd, M., Damoc, E., Denisov, E., Grinfeld, D., Bennett, A., Agbandje-McKenna, M., Makarov, A., & Heck, A. J. R. (2014) · Journal of the American Chemical Society · doi:10.1021/ja502616y · Cited by 168 · cited 1×
“For example, mass spectrometry has been used to resolve heterogeneity in recombinant adeno-associated virus (AAV) capsids,([14]) and examine genome packaging in AAV gene therapy vectors.”
Resolving Adeno-Associated Viral Particle Diversity With Charge Detection Mass Spectrometry
Pierson, E. E., Keifer, D. Z., Asokan, A., & Jarrold, M. F. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b00883 · Cited by 152
Self-citation
Cited by
Integrative structure and functional anatomy of a nuclear pore complex
Kim, S. J., Fernandez-Martinez, J., Nudelman, I., Shi, Y., Zhang, W., Raveh, B., Herricks, T., Slaughter, B. D., Hogan, J. A., Upla, P., et al. (2018) · Nature · doi:10.1038/nature26003 · Cited by 490
Self-citationHarper, C. C., Elliott, A. G., Oltrogge, L. M., Savage, D. F., & Williams, E. R. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01669 · Cited by 84
Kafader, J. O., Durbin, K. R., Melani, R. D., Des Soye, B. J., Schachner, L. F., Senko, M. W., Compton, P. D., & Kelleher, N. L. (2020) · Journal of Proteome Research · doi:10.1021/acs.jproteome.9b00797 · Cited by 76
Metadata
- Authors
- Keifer, D. Z., Motwani, T., Teschke, C. M., & Jarrold, M. F.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2016-08-05
- Volume
- 30
- Issue
- 17
- Pages
- 1957-1962
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2513293999
- Cited by
- 54
- References
- 2
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of the accurate mass of a 50 MDa infectious virus. https://app.cochat.ai/papers/10.1002/rcm.7673
- The paper
- Keifer, D. Z., Motwani, T., Teschke, C. M., & Jarrold, M. F. (2016). Measurement of the accurate mass of a 50 MDa infectious virus. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.7673
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.