Classification of adsorbed protein static ToF‐SIMS spectra by principal component analysis and neural networks
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Analysis of the static time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) spectra of adsorbed protein films is reported using principal component analysis (PCA) and a novel artificial neural network (ANN) approach, NeuroSpectraNet , to classify chemically the spectra of the protein films. The ease of application and the efficiency with which each approach classified positive ion spectra from adsorbed films of 13 different proteins is reported and assessed. The ToF‐SIMS spectra of adsorbed protein films are especially difficult to analyze owing to the absence of unique peaks in the spectra of different proteins. Although PCA was able to differentiate successfully ToF‐SIMS spectra of adsorbed protein films using the ions generated from the fragmentation of the amino acids, differentiation of the spectra using the entire spectrum was unsuccessful. Outliers in several of the protein groups make classification of unknown spectra difficult, despite the use of only amino‐acid‐specific ions. However, NeuroSpectraNet successfully classified the spectra from 11 of the protein films using the whole positive ion spectra after a vector analysis enhancement had been incorporated into the neural network. Full classification of all 13 proteins was achieved by using the combined positive and negative ion spectra. However, as with PCA, ANN classification was enhanced when the input patterns only contained amino‐acid‐specific ions. The complex and multivariate nature of static SIMS spectra is a domain well suited to the application of neural networks for pattern recognition and classification. Copyright © 2002 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Self-Organization and Associative Memory
Kohonen, T. (1989) · Springer Series in Information Sciences · doi:10.1007/978-3-642-88163-3 · Cited by 8,740
Cited by
Heller-Krippendorf, D. (2025) · Secondary Ion Mass Spectrometry · doi:10.1039/9781837674763-00229 · Cited by 1,431
Orientation and characterization of immobilized antibodies for improved immunoassays (Review)
Welch, N. G., Scoble, J. A., Muir, B. W., & Pigram, P. J. (2017) · Biointerphases · doi:10.1116/1.4978435 · Cited by 414
Abiotic synthesis of amino acids in the recesses of the oceanic lithosphere
Ménez, B., Pisapia, C., Andreani, M., Jamme, F., Vanbellingen, Q. P., Brunelle, A., Richard, L., Dumas, P., & Réfrégiers, M. (2018) · Nature · doi:10.1038/s41586-018-0684-z · Cited by 249
Spectroscopic studies on organic matter from triassic reptile bones, Upper Silesia, Poland
Surmik, D., Boczarowski, A., Balin, K., Dulski, M., Szade, J., Kremer, B., & Pawlicki, R. (2016) · PLOS ONE · doi:10.1371/journal.pone.0151143 · Cited by 46
Madiona, R. M. T., Bamford, S. E., Winkler, D. A., Muir, B. W., & Pigram, P. J. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b01951 · Cited by 25
Metadata
- Authors
- Sanni, O. D., Wagner, M. S., Briggs, D., Castner, D. G., & Vickerman, J. C.
- Venue
- Surface and Interface Analysis
- Publisher
- Wiley
- Published
- 2002-08-29
- Volume
- 33
- Issue
- 9
- Pages
- 715-728
- ISSN
- 0142-2421 (ISSN-L)
- 1096-9918
- OpenAlex
- W2049936734
- Cited by
- 110
- References
- 1
- FWCI
- 4.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.