The DOI matches its Crossref record; 92 of the 92 references it cites were found in a registry or an index.
Orientation and characterization of immobilized antibodies for improved immunoassays (Review)
Open accessAbstract
Orientation of surface immobilized capture proteins, such as antibodies, plays a critical role in the performance of immunoassays. The sensitivity of immunodiagnostic procedures is dependent on presentation of the antibody, with optimum performance requiring the antigen binding sites be directed toward the solution phase. This review describes the most recent methods for oriented antibody immobilization and the characterization techniques employed for investigation of the antibody state. The introduction describes the importance of oriented antibodies for maximizing biosensor capabilities. Methods for improving antibody binding are discussed, including surface modification and design (with sections on surface treatments, three-dimensional substrates, self-assembled monolayers, and molecular imprinting), covalent attachment (including targeting amine, carboxyl, thiol and carbohydrates, as well as “click” chemistries), and (bio)affinity techniques (with sections on material binding peptides, biotin-streptavidin interaction, DNA directed immobilization, Protein A and G, Fc binding peptides, aptamers, and metal affinity). Characterization techniques for investigating antibody orientation are discussed, including x-ray photoelectron spectroscopy, spectroscopic ellipsometry, dual polarization interferometry, neutron reflectometry, atomic force microscopy, and time-of-flight secondary-ion mass spectrometry. Future perspectives and recommendations are offered in conclusion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Self-Assembled Monolayers of Thiolates on Metals as a Form of Nanotechnology
Love, J. C., Estroff, L. A., Kriebel, J. K., Nuzzo, R. G., & Whitesides, G. M. (2005) · Chemical Reviews · doi:10.1021/cr0300789 · Cited by 8,282
Isolation of pure IgG1, IgG2a and IgG2b immunoglobulins from mouse serum using protein A-Sepharose
Ey, P. L., Prowse, S. J., & Jenkin, C. R. (1978) · Immunochemistry · doi:10.1016/0161-5890(78)90070-6 · Cited by 2,685
Metal chelate affinity chromatography, a new approach to protein fractionation
PORATH, J., CARLSSON, J., OLSSON, I., & BELFRAGE, G. (1975) · Nature · doi:10.1038/258598a0 · Cited by 2,068
Plasma-surface modification of biomaterials
Chu, P. (2002) · Materials Science and Engineering: R: Reports · doi:10.1016/s0927-796x(02)00004-9 · Cited by 1,578
Polymer surface modification for the attachment of bioactive compounds
Goddard, J. M., & Hotchkiss, J. H. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.04.002 · Cited by 1,379
Hochuli, E., Döbeli, H., & Schacher, A. (1987) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)93969-4 · Cited by 1,112
Polymer surface modification by plasmas and photons
Chan, C.-M., Ko, T.-M., & Hiraoka, H. (1996) · Surface Science Reports · doi:10.1016/0167-5729(96)80003-3 · Cited by 1,074
Hochuli, E., Bannwarth, W., Döbeli, H., Gentz, R., & Stüber, D. (1988) · Nature Biotechnology · doi:10.1038/nbt1188-1321 · Cited by 1,046
Siow, K. S., Britcher, L., Kumar, S., & Griesser, H. J. (2006) · Plasma Processes and Polymers · doi:10.1002/ppap.200600021 · Cited by 972
Awaja, F., Gilbert, M., Kelly, G., Fox, B., & Pigram, P. J. (2009) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.04.007 · Cited by 928
Self-citation
Cited by
Ultrasensitive and Highly Specific Lateral Flow Assays for Point-of-Care Diagnosis
Liu, Y., Zhan, L., Qin, Z., Sackrison, J., & Bischof, J. C. (2021) · ACS Nano · doi:10.1021/acsnano.0c10035 · Cited by 626
The Role of Electrochemical Immunosensors in Clinical Analysis
Mollarasouli, F., Kurbanoglu, S., & Ozkan, S. A. (2019) · Biosensors · doi:10.3390/bios9030086 · Cited by 293
Zhang, L., Mazouzi, Y., Salmain, M., Liedberg, B., & Boujday, S. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112370 · Cited by 258
Label-Free Plasmonic Biosensors for Point-of-Care Diagnostics: A Review
Soler, M., Huertas, C. S., & Lechuga, L. M. (2019) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2019.1554435 · Cited by 236
Chirality in adsorption on solid surfaces
Zaera, F. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00367f · Cited by 172
Metadata
- Authors
- Welch, N. G., Scoble, J. A., Muir, B. W., & Pigram, P. J.
- Venue
- Biointerphases
- Publisher
- American Vacuum Society
- Published
- 2017-03-16
- Volume
- 12
- Issue
- 2
- Pages
- 02D301-02D301
- ISSN
- 1559-4106 (ISSN-L)
- 1934-8630
- OpenAlex
- W2595421984
- Cited by
- 414
- References
- 92
- FWCI
- 11.65
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Orientation and characterization of immobilized antibodies for improved immunoassays (Review). https://app.cochat.ai/papers/10.1116/1.4978435
- The paper
- Welch, N. G., Scoble, J. A., Muir, B. W., & Pigram, P. J. (2017). Orientation and characterization of immobilized antibodies for improved immunoassays (Review). Biointerphases. https://doi.org/10.1116/1.4978435
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.