The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Optical microarray biosensing techniques
Abstract
Microarrays provide a powerful analytical tool for the simultaneous analyses of thousands of parameters, be they DNA or proteins, in a single experiment. However, a number of challenges continue to hinder the widespread application of microarray assays for analytical and diagnostic purposes. Advances in detection methods can help overcome some of these challenges by improving sensitivity and reliability in signal detection and by enabling real‐time detection of binding events. Thus, the aim of this review is to highlight the most promising optical microarray biosensing techniques. The principles of techniques making use of labels, including scanner type, total internal reflection type, fiber‐optics‐based, and SPR‐enhanced fluorescence, are described, along with a brief summary of labeling strategies. State of the art label‐free techniques, including imaging SPR and imaging ellipsometry, are also reviewed. Examples of microarray‐based assays using each technique are given to illustrate both their usefulness and their limits of detection. Furthermore, the most competitive commercial microarray systems are presented and compared with one another in the context of their detection system. Finally, a discussion of the remaining challenges as well as trends and future applications of microarrays are presented in the context of optical sensing. Copyright © 2006 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Haes, A. J., & Van Duyne, R. P. (2002) · Journal of the American Chemical Society · doi:10.1021/ja020393x · Cited by 2,057
Global Analysis of Protein Activities Using Proteome Chips
Zhu, H., Bilgin, M., Bangham, R., Hall, D., Casamayor, A., Bertone, P., Lan, N., Jansen, R., Bidlingmaier, S., Houfek, T., et al. (2001) · Science · doi:10.1126/science.1062191 · Cited by 1,884
Cited by
Surface Plasmon Resonance Sensors for Detection of Chemical and Biological Species
Homola, J. (2008) · Chemical Reviews · doi:10.1021/cr068107d · Cited by 4,525
Fiber-Optic Chemical Sensors and Biosensors
Wolfbeis, O. S. (2008) · Analytical Chemistry · doi:10.1021/ac800473b · Cited by 571
Microfluidic-based biosensors toward point-of-care detection of nucleic acids and proteins
Choi, S., Goryll, M., Sin, L. Y. M., Wong, P. K., & Chae, J. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0638-8 · Cited by 270
Metadata
- Authors
- Bally, M., Halter, M., Vörös, J., & Grandin, H. M.
- Venue
- Surface and Interface Analysis
- Publisher
- Wiley
- Published
- 2006-10-18
- Volume
- 38
- Issue
- 11
- Pages
- 1442-1458
- ISSN
- 0142-2421 (ISSN-L)
- 1096-9918
- OpenAlex
- W2171661815
- Cited by
- 166
- References
- 2
- FWCI
- 6.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical microarray biosensing techniques. https://app.cochat.ai/papers/10.1002/sia.2375
- The paper
- Bally, M., Halter, M., Vörös, J., & Grandin, H. M. (2006). Optical microarray biosensing techniques. Surface and Interface Analysis. https://doi.org/10.1002/sia.2375
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.