A Nanoscale Optical Biosensor: Sensitivity and Selectivity of an Approach Based on the Localized Surface Plasmon Resonance Spectroscopy of Triangular Silver Nanoparticles
Abstract
Triangular silver nanoparticles ( approximately 100 nm wide and 50 nm high) have remarkable optical properties. In particular, the peak extinction wavelength, lambda(max) of their localized surface plasmon resonance (LSPR) spectrum is unexpectedly sensitive to nanoparticle size, shape, and local ( approximately 10-30 nm) external dielectric environment. This sensitivity of the LSPR lambda(max) to the nanoenvironment has allowed us to develop a new class of nanoscale affinity biosensors. The essential characteristics and operational principles of these LSPR nanobiosensors will be illustrated using the well-studied biotin-streptavidin system. Exposure of biotin-functionalized Ag nanotriangles to 100 nM streptavidin (SA) caused a 27.0 nm red-shift in the LSPR lambda(max). The LSPR lambda(max) shift, DeltaR/DeltaR(max), versus [SA] response curve was measured over the concentration range 10(-)(15) M < [SA] < 10(-)(6) M. Comparison of the data with the theoretical normalized response expected for 1:1 binding of a ligand to a multivalent receptor with different sites but invariant affinities yielded approximate values for the saturation response, DeltaR(max) = 26.5 nm, and the surface-confined thermodynamic binding constant K(a,surf) = 10(11) M(-)(1). At present, the limit of detection (LOD) for the LSPR nanobiosensor is found to be in the low-picomolar to high-femtomolar region. A strategy to amplify the response of the LSPR nanobiosensor using biotinylated Au colloids and thereby further improve the LOD is demonstrated. Several control experiments were performed to define the LSPR nanobiosensor's response to nonspecific binding as well as to demonstrate its response to the specific binding of another protein. These include the following: (1) electrostatic binding of SA to a nonbiotinylated surface, (2) nonspecific interactions of prebiotinylated SA to a biotinylated surface, (3) nonspecific interactions of bovine serum albumin to a biotinylated surface, and (4) specific binding of anti-biotin to a biotinylated surface. The LSPR nanobiosensor provides a pathway to ultrasensitive biodetection experiments with extremely simple, small, light, robust, low-cost instrumentation that will greatly facilitate field-portable environmental or point-of-service medical diagnostic applications.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The dependence of plasmon resonance on the refractive index of the medium can be exploited for optical sensing applications, even at single molecule level, as long as molecules cause a variation of the refractive index.
“The above mentioned dependence of the plasmon resonance on the refractive index of the medium can be exploited for optical sensing applications [163], even at a single molecule level [164,165], as it allows the detection of molecules dissolved in the colloidal phase or adsorbed on the surface, as long as they cause a variation of the refractive index of the medium [166,167].”
From Nanoparticles Engineering by Pulsed Laser Ablation in Liquids: Concepts and Applications (2020) · cites this paper as [167]
Cited by
Sorted by citations
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603 · see citing works
Nanoparticles Engineering by Pulsed Laser Ablation in Liquids: Concepts and Applications
Fazio, E., Gökce, B., De Giacomo, A., Meneghetti, M., Compagnini, G., Tommasini, M., Waag, F., Lucotti, A., Zanchi, C. G., Ossi, P. M., et al. (2020) · Nanomaterials · doi:10.3390/nano10112317 · Cited by 346 · see citing works
Growth Kinetics and Sensing Features of Colloidal Silver Nanoplates
Compagnini, G., Condorelli, M., Fragalà, M. E., Scardaci, V., Tinnirello, I., Puglisi, O., Neri, F., & Fazio, E. (2019) · Journal of Nanomaterials · doi:10.1155/2019/7084731 · Cited by 22 · see citing works
- Authors
- Haes, A. J., & Van Duyne, R. P.
- Affiliations
- Northwestern University (US)
- Contribution from the Department of Chemistry, Northwestern University, Evanston, Illinois 60208-3113
- ORCID
- Haes, Amanda J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-08-08
- Volume
- 124
- Issue
- 35
- Pages
- 10596-10604
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2006882472
- Cited by
- 2,057
- References
- 0
- Citations by year
- 2026: 32 · 2025: 31 · 2024: 61 · 2023: 36 · 2022: 44 · 2021: 61 · 2020: 73 · 2019: 76 · 2018: 97 · 2017: 100 · 2016: 90 · 2015: 109 · 2014: 141 · 2013: 134 · 2012: 127
- FWCI
- 37.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the American Chemical Society (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Plasmonic and Surface Plasmon Research
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Keywords
- localized surface plasmon resonance, silver nanotriangles, optical biosensors, biotin-streptavidin binding, detection limit, binding constant, response amplification, non-specific binding, protein detection, surface plasmon resonance spectroscopy
- MeSH terms
- Biotin, Colloids, Gold, Kinetics, Protein Binding, Sensitivity and Specificity, Serum Albumin, Bovine, Silver, Surface Properties, Biosensing Techniques, Streptavidin, Surface Plasmon Resonance, Nanotechnology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review