Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 238

The DOI matches its Crossref record.

ARXPS characterisation of plasma polymerised surface chemical gradients

Parry, K. L., Shard, A. G., Short, R. D., White, R. G., Whittle, J. D., Wright, A.·2006·Surface and Interface Analysis

Abstract

The aim of this paper is twofold: first to report on the lateral and vertical characterisation of a surface chemical gradient of carboxylic‐acid functionality and second, to demonstrate the use of said gradient to probe the passive adsorption of immunoglobulin G (IgG) as a function of the density of surface carboxylic‐acid groups. A surface chemical gradient of carboxylic‐acid functionality was fabricated by the plasma copolymerisation of octadiene (OD) and acrylic acid (AA). The plasma‐polymerised gradient was over 12 mm, with 2 mm of plasma‐polymerised OD at one end and 2 mm of plasma‐polymerised AA at the other. By means of linescan angle resolved x‐ray photoelectron spectroscopy (ARXPS) it is shown precisely how acid functionality varies from the 2 mm position (OD end) on the gradient to the 10 mm position (AA end). By recording data from 16 angles at each of the 25 sampling points along the gradient, it is shown that the surface gradient also changes vertically, most notably in the thickness of the plasma polymer. At the OD end the plasma‐polymerised layer is 6.3 nm thick, while at the AA end the plasma‐polymerised layer is 5 nm. More subtle changes in chemistry through the plasma‐polymerised layer are shown at the 7.5 and 10 mm points. An identical gradient is used to probe IgG adsorption along the length of the gradient. ARXPS is used to monitor the nitrogen 1s (N1s) signal at 25 points, the N1s signal being unique to adsorbed IgG. It is demonstrated that IgG adsorbs in far greater amount (IgG per unit area) at the OD end, and the amount of adsorbed IgG decreases along the length of the gradient. It is estimated that >200 ng/cm 2 adsorbed at the OD, while at the AA the amount adsorbed was <20 ng/cm 2 . Copyright © 2006 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/sia.2400

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 238

Metadata

Authors
Parry, K. L., Shard, A. G., Short, R. D., White, R. G., Whittle, J. D., & Wright, A.
Venue
Surface and Interface Analysis
Publisher
Wiley
Published
2006-10-18
Volume
38
Issue
11
Pages
1497-1504
ISSN
  • 0142-2421 (ISSN-L)
  • 1096-9918
OpenAlex
W2025990388
Cited by
238
References
0
FWCI
3.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: ARXPS characterisation of plasma polymerised surface chemical gradients. https://app.cochat.ai/papers/10.1002/sia.2400
The paper
Parry, K. L., Shard, A. G., Short, R. D., White, R. G., Whittle, J. D., & Wright, A. (2006). ARXPS characterisation of plasma polymerised surface chemical gradients. Surface and Interface Analysis. https://doi.org/10.1002/sia.2400

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.