The DOI matches its Crossref record.
ARXPS characterisation of plasma polymerised surface chemical gradients
Abstract
The aim of this paper is twofold: first to report on the lateral and vertical characterisation of a surface chemical gradient of carboxylic‐acid functionality and second, to demonstrate the use of said gradient to probe the passive adsorption of immunoglobulin G (IgG) as a function of the density of surface carboxylic‐acid groups. A surface chemical gradient of carboxylic‐acid functionality was fabricated by the plasma copolymerisation of octadiene (OD) and acrylic acid (AA). The plasma‐polymerised gradient was over 12 mm, with 2 mm of plasma‐polymerised OD at one end and 2 mm of plasma‐polymerised AA at the other. By means of linescan angle resolved x‐ray photoelectron spectroscopy (ARXPS) it is shown precisely how acid functionality varies from the 2 mm position (OD end) on the gradient to the 10 mm position (AA end). By recording data from 16 angles at each of the 25 sampling points along the gradient, it is shown that the surface gradient also changes vertically, most notably in the thickness of the plasma polymer. At the OD end the plasma‐polymerised layer is 6.3 nm thick, while at the AA end the plasma‐polymerised layer is 5 nm. More subtle changes in chemistry through the plasma‐polymerised layer are shown at the 7.5 and 10 mm points. An identical gradient is used to probe IgG adsorption along the length of the gradient. ARXPS is used to monitor the nitrogen 1s (N1s) signal at 25 points, the N1s signal being unique to adsorbed IgG. It is demonstrated that IgG adsorbs in far greater amount (IgG per unit area) at the OD end, and the amount of adsorbed IgG decreases along the length of the gradient. It is estimated that >200 ng/cm 2 adsorbed at the OD, while at the AA the amount adsorbed was <20 ng/cm 2 . Copyright © 2006 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multi-anionic and -cationic compounds: new high entropy materials for advanced Li-ion batteries
Wang, Q., Sarkar, A., Wang, D., Velasco, L., Azmi, R., Bhattacharya, S. S., Bergfeldt, T., Düvel, A., Heitjans, P., Brezesinski, T., et al. (2019) · Energy & Environmental Science · doi:10.1039/c9ee00368a · Cited by 447
Le Guével, X., Hötzer, B., Jung, G., Hollemeyer, K., Trouillet, V., & Schneider, M. (2011) · The Journal of Physical Chemistry C · doi:10.1021/jp111820b · Cited by 384
Kim, A.-Y., Strauss, F., Bartsch, T., Teo, J. H., Hatsukade, T., Mazilkin, A., Janek, J., Hartmann, P., & Brezesinski, T. (2019) · Chemistry of Materials · doi:10.1021/acs.chemmater.9b02947 · Cited by 266
He, J., Tao, T., Yang, F., & Sun, Z. (2022) · ChemSusChem · doi:10.1002/cssc.202200817 · Cited by 30
He, J., Tao, T., Yang, F., & Sun, Z. (2022) · ChemSusChem · doi:10.1002/cssc.202102522 · Cited by 29
Metadata
- Authors
- Parry, K. L., Shard, A. G., Short, R. D., White, R. G., Whittle, J. D., & Wright, A.
- Venue
- Surface and Interface Analysis
- Publisher
- Wiley
- Published
- 2006-10-18
- Volume
- 38
- Issue
- 11
- Pages
- 1497-1504
- ISSN
- 0142-2421 (ISSN-L)
- 1096-9918
- OpenAlex
- W2025990388
- Cited by
- 238
- References
- 0
- FWCI
- 3.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ARXPS characterisation of plasma polymerised surface chemical gradients. https://app.cochat.ai/papers/10.1002/sia.2400
- The paper
- Parry, K. L., Shard, A. G., Short, R. D., White, R. G., Whittle, J. D., & Wright, A. (2006). ARXPS characterisation of plasma polymerised surface chemical gradients. Surface and Interface Analysis. https://doi.org/10.1002/sia.2400
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.