Three validation metrics for automated probabilistic image segmentation of brain tumours
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The validity of brain tumour segmentation is an important issue in image processing because it has a direct impact on surgical planning. We examined the segmentation accuracy based on three two‐sample validation metrics against the estimated composite latent gold standard, which was derived from several experts' manual segmentations by an EM algorithm. The distribution functions of the tumour and control pixel data were parametrically assumed to be a mixture of two beta distributions with different shape parameters. We estimated the corresponding receiver operating characteristic curve, Dice similarity coefficient, and mutual information, over all possible decision thresholds. Based on each validation metric, an optimal threshold was then computed via maximization. We illustrated these methods on MR imaging data from nine brain tumour cases of three different tumour types, each consisting of a large number of pixels. The automated segmentation yielded satisfactory accuracy with varied optimal thresholds. The performances of these validation metrics were also investigated via Monte Carlo simulation. Extensions of incorporating spatial correlation structures using a Markov random field model were considered. Copyright © 2004 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, Y., Brady, M., & Smith, S. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906424 · Cited by 6,982
THE DISTRIBUTION OF THE FLORA IN THE ALPINE ZONE. 1
Jaccard, P. (1912) · New Phytologist · doi:10.1111/j.1469-8137.1912.tb05611.x · Cited by 4,561
Exact Maximum A Posteriori Estimation for Binary Images
Greig, D. M., Porteous, B. T., & Seheult, A. H. (1989) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1989.tb01764.x · Cited by 1,055
Adaptive, template moderated, spatially varying statistical classification
Warfield, S. K., Kaus, M., Jolesz, F. A., & Kikinis, R. (2000) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00003-7 · Cited by 402
Self-citation
Cited by
Metrics for evaluating 3D medical image segmentation: analysis, selection, and tool
Taha, A. A., & Hanbury, A. (2015) · BMC Medical Imaging · doi:10.1186/s12880-015-0068-x · Cited by 2,920
Warfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,335
“Furthermore, measures inspired by information theory have been applied [14], [ 15 ].”
MethodSelf-citationStatistical validation of image segmentation quality based on a spatial overlap index1
Zou, K. H., Warfield, S. K., Bharatha, A., Tempany, C. M. C., Kaus, M. R., Haker, S. J., Wells, W. M., Jolesz, F. A., & Kikinis, R. (2004) · Academic Radiology · doi:10.1016/s1076-6332(03)00671-8 · Cited by 1,849
Self-citationReceiver-operating characteristic analysis for evaluating diagnostic tests and predictive models
Zou, K. H., O’Malley, A. J., & Mauri, L. (2007) · Circulation · doi:10.1161/circulationaha.105.594929 · Cited by 1,473
Self-citationA survey of MRI-based medical image analysis for brain tumor studies
Bauer, S., Wiest, R., Nolte, L.-P., & Reyes, M. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/13/r97 · Cited by 1,036
Metadata
- Authors
- Zou, K. H., Wells, W. M., Kikinis, R., & Warfield, S. K.
- Venue
- Statistics in Medicine
- Publisher
- Wiley
- Published
- 2004-04-05
- Volume
- 23
- Issue
- 8
- Pages
- 1259-1282
- ISSN
- 0277-6715 (ISSN-L)
- 1097-0258
- OpenAlex
- W1994343730
- Cited by
- 92
- References
- 4
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three validation metrics for automated probabilistic image segmentation of brain tumours. https://app.cochat.ai/papers/10.1002/sim.1723
- The paper
- Zou, K. H., Wells, W. M., Kikinis, R., & Warfield, S. K. (2004). Three validation metrics for automated probabilistic image segmentation of brain tumours. Statistics in Medicine. https://doi.org/10.1002/sim.1723
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.