CoChat

Comparison of the effect of volume conduction on EEG coherence with the effect of field spread on MEG coherence

Winter, William R., Nunez, Paul L., Ding, Jian, Srinivasan, Ramesh · 2007 · Statistics in Medicine
Cited by 121

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

We analyzed models of volume conduction and magnetic field spread to account for aspects of spatial structure in electroencephalographic (EEG) and magnetoencephalographic (MEG) coherence. The head volume conduction model consisted of three confocal ellipsoids, representing three layers (brain, skull, and scalp) with different tissue conductivities, while the magnetic field model follows from the Biot–Savart law in a spherically symmetric medium. Source models were constructed based on magnetic resonance imaging data from three subjects, approximating neocortical current source distributions as dipoles oriented perpendicular to the local cortical surface. Assuming that every source is uncorrelated to every other source, coherence between sensors due to volume conduction and field‐spread effects was estimated. Spatial properties of the model coherences were then compared with simultaneously recorded spontaneous EEG and MEG. In both models and experimental data, EEG and MEG coherence was elevated between closely spaced channels. At very large channel separations, the field‐spread effect on MEG coherence appears smaller than the volume conduction effect on EEG coherence. In EEG coherence studies, surface Laplacian methods can be used to remove volume conduction effects. With single‐coil magnetometers, MEG coherences are free of field effects only for sensor pairs separated by more than 20 cm. Model coherences resemble most high‐frequency (e.g. >20 Hz) data; volume conduction and field‐spread effects are independent of frequency, suggesting mostly uncorrelated sources in these bands. High‐frequency EEG and MEG coherence can evidently serve as an estimate of coherence effects due to volume conduction and field effects, when source and head models are not available for individual subjects. Copyright © 2007 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/sim.2978

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 121

Metadata

Authors
Winter, W. R., Nunez, P. L., Ding, J., & Srinivasan, R.
Venue
Statistics in Medicine
Publisher
Wiley
Published
2007-07-02
Volume
26
Issue
21
Pages
3946-3957
ISSN
  • 0277-6715 (ISSN-L)
  • 1097-0258
OpenAlex
W2105269248
Cited by
121
References
3
FWCI
1.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of the effect of volume conduction on EEG coherence with the effect of field spread on MEG coherence. https://app.cochat.ai/papers/10.1002/sim.2978
The paper
Winter, W. R., Nunez, P. L., Ding, J., & Srinivasan, R. (2007). Comparison of the effect of volume conduction on EEG coherence with the effect of field spread on MEG coherence. Statistics in Medicine. https://doi.org/10.1002/sim.2978

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.